Quartz-enhanced photoacoustic spectroscopy sensor for ethylene detection with a 3.32 μm distributed feedback laser diode

被引:34
|
作者
Ba, T. Nguyen [1 ,2 ]
Triki, M. [1 ,2 ]
Desbrosses, G. [3 ]
Vicet, A. [1 ,2 ]
机构
[1] Univ Montpellier, IES, UMR 5214, F-34000 Montpellier, France
[2] CNRS, IES, UMR 5214, F-34000 Montpellier, France
[3] Univ Montpellier 2, SupAgro, UM2, LSTM,UMR 113,IRD,CIRAD, F-34095 Montpellier, France
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2015年 / 86卷 / 02期
关键词
Absorption co-efficient - Absorption lines - Biological samples - Detection setup - Distributed feedback - Near room temperature - Normalized noise - Quartz-enhanced photoacoustic spectroscopies;
D O I
10.1063/1.4913383
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An antimonide distributed feedback quantum wells diode laser operating at 3.32 mu m at near room temperature in the continuous wave regime has been used to perform ethylene detection based on quartz enhanced photoacoustic spectroscopy. An absorption line centered at 3007.52 cm(-1) was investigated and a normalized noise equivalent absorption coefficient (1 sigma) of 3.09 10(-7) cm(-1) W Hz(-1/2) was obtained. The linearity and the stability of the detection have been evaluated. Biological samples' respiration has been measured to validate the feasibility of the detection setup in an agronomic environment, especially on ripening apples. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Hydrogen peroxide detection with quartz-enhanced photoacoustic spectroscopy using a distributed-feedback quantum cascade laser
    Ren, Wei
    Jiang, Wenzhe
    Sanchez, Nancy P.
    Patimisco, Pietro
    Spagnolo, Vincenzo
    Zah, Chung-en
    Xie, Feng
    Hughes, Lawrence C.
    Griffin, Robert J.
    Tittel, Frank K.
    [J]. APPLIED PHYSICS LETTERS, 2014, 104 (04)
  • [2] Carbon dioxide and ammonia detection using 2 μm diode laser based quartz-enhanced photoacoustic spectroscopy
    Lewicki, R.
    Wysocki, G.
    Kosterev, A. A.
    Tittel, F. K.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2007, 87 (01): : 157 - 162
  • [3] Carbon dioxide and ammonia detection using 2 μm diode laser based quartz-enhanced photoacoustic spectroscopy
    R. Lewicki
    G. Wysocki
    A.A. Kosterev
    F.K. Tittel
    [J]. Applied Physics B, 2007, 87 : 157 - 162
  • [4] Quartz-enhanced photoacoustic detection of ethylene using a 10.5 μm quantum cascade laser
    Wang, Zhen
    Li, Zhili
    Ren, Wei
    [J]. OPTICS EXPRESS, 2016, 24 (04): : 4143 - 4154
  • [5] Detection of nitric oxide in air with a 5.2 μm distributed-feedback quantum cascade laser using quartz-enhanced photoacoustic spectroscopy
    Gray, Stuart
    Liu, Anping
    Xie, Feng
    Zah, Chung-en
    [J]. OPTICS EXPRESS, 2010, 18 (22): : 23353 - 23357
  • [6] Quartz enhanced photoacoustic spectroscopy with a 3.38 μm antimonide distributed feedback laser
    Jahjah, Mohammad
    Belahsene, Sofiane
    Naehle, Lars
    Fischer, Marc
    Koeth, Johannes
    Rouillard, Yves
    Vicet, Aurore
    [J]. OPTICS LETTERS, 2012, 37 (13) : 2502 - 2504
  • [7] High-Sensitive Carbon Dioxide Detection Using Quartz-Enhanced Photoacoustic Spectroscopy with a 2. 0 μm Distributed Feedback Laser
    Liu Xiao-li
    Wu Hong-peng
    Shao Jie
    Dong Lei
    Zhang Lei
    Ma Wei-guang
    Yin Wang-bao
    Jia Suo-tang
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35 (08) : 2078 - 2082
  • [8] Quartz-enhanced photoacoustic spectroscopy
    Kosterev, AA
    Bakhirkin, YA
    Curl, RF
    Tittel, FK
    [J]. OPTICS LETTERS, 2002, 27 (21) : 1902 - 1904
  • [9] Theoretical analysis of a quartz-enhanced photoacoustic spectroscopy sensor
    N. Petra
    J. Zweck
    A. A. Kosterev
    S. E. Minkoff
    D. Thomazy
    [J]. Applied Physics B, 2009, 94 : 673 - 680
  • [10] Ammonia detection by use of quartz-enhanced photoacoustic spectroscopy with a near-IR telecommunication diode laser
    Kosterev, AA
    Tittel, FK
    [J]. APPLIED OPTICS, 2004, 43 (33) : 6213 - 6217