Endophthalmitis associated with the Ahmed glaucoma valve implant

被引:148
|
作者
Al-Torbak, AA
Al-Shahwan, S
Al-Jadaan, I
Al-Hommadi, A
Edward, DP
机构
[1] King Khalid Eye Specialist Hosp, Dept Ophthalmol, Riyadh 11462, Saudi Arabia
[2] King Khalid Eye Specialist Hosp, Dept Res, Riyadh 11462, Saudi Arabia
[3] Univ Illinois, Dept Ophthalmol, Chicago, IL 60680 USA
关键词
D O I
10.1136/bjo.2004.049015
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To investigate the rate, risk factors, clinical course, and treatment outcomes of endophthalmitis following glaucoma drainage implant (GDI) surgery. Methods: A computerised relational database search was conducted to identify all patients who were implanted with Ahmed glaucoma valve (AGV) and developed endophthalmitis following surgery at the King Khaled Eye Specialist Hospital in Riyadh, Saudi Arabia, between 1 January 1994 and 30 November 2003. Only medical records of the patients who developed endophthalmitis were retrospectively reviewed. Results: 542 eyes of 505 patients who were on active follow up were included in the study. Endophthalmitis developed in nine (1.7%) eyes; the rate was five times higher in children than in adults. Delayed endophthalmitis (developed 6 weeks after surgery) occurred in eight of nine eyes. Conjunctival erosion overlying the AGV tube was present in six of nine eyes. Common organisms isolated in the vitreous included Haemophilus influenzae and Streptococcus species. Multiple regression analysis revealed that younger age and conjunctival erosion over the tube were significant risk factors associated with endophthalmitis. Conclusion: Endophthalmitis is a rare complication of GDI surgery that appears to be more common in children. Conjunctival dehiscence over the GDI tube seems to represent a major risk factor for endophthalmitis. Prompt surgical revision of an exposed GDI tube is highly recommended.
引用
收藏
页码:454 / 458
页数:5
相关论文
共 50 条
  • [1] Delayed Endophthalmitis in a child following an Ahmed glaucoma valve implant
    Al-Torbaq, AA
    Edward, DP
    [J]. JOURNAL OF AAPOS, 2002, 6 (02): : 123 - 125
  • [2] Propionibacterium acnes endophthalmitis in Ahmed glaucoma valve
    Gutiérrez-Díaz, E
    Montero-Rodríguez, M
    Mencía-Gutiérrez, E
    Fernández-González, MC
    Pérez-Blázquez, E
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2001, 11 (04) : 383 - 385
  • [3] Clinical Manifestations and Prognosis in Patients with Infectious Endophthalmitis after Ahmed Glaucoma Valve Implant Surgery
    Hong, Chae Min
    Kim, Gyu Nam
    Cho, Yong Wun
    Kim, Seong-Jae
    Chung, Inyoung
    Yoo, Woong-Sun
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (11): : 1048 - 1054
  • [4] Ahmed valve implant for uncontrolled uveitic glaucoma
    Gil-Carrasco, F
    Salinas-VanOrman, E
    Recillas-Gispert, C
    Paczka, JA
    Gilbert, ME
    Arellanes-Garcia, L
    [J]. OCULAR IMMUNOLOGY AND INFLAMMATION, 1998, 6 (01) : 27 - 37
  • [5] A clinical study of the Ahmed glaucoma valve implant in advanced glaucoma
    Ayyala, RS
    Zurakowski, D
    Smith, JA
    Monshizadeh, R
    Netland, PA
    Richards, DW
    Layden, WE
    [J]. OPHTHALMOLOGY, 1998, 105 (10) : 1968 - 1976
  • [6] Intraoperative management of nonfunctioning Ahmed glaucoma valve implant
    Setabutr, P
    Bell, NP
    Feldman, RM
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2006, 37 (01): : 62 - 64
  • [7] Ahmed glaucoma valve implant: Experience in East Africa
    Kiage, D. O.
    Gradin, D.
    Gichuhi, S.
    Damji, K. F.
    [J]. MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2009, 16 (03) : 151 - 155
  • [8] Nocardia brasiliensis Endophthalmitis in a Patient with an Exposed Ahmed Glaucoma Drainage Implant
    Stewart, Michael W.
    Bolling, James P.
    Bendel, Rick E.
    [J]. OCULAR IMMUNOLOGY AND INFLAMMATION, 2013, 21 (01) : 54 - 55
  • [9] Initial clinical experience with the Ahmed glaucoma valve implant in the management of neovascular glaucoma
    Patel, S
    Ge, N
    Varma, R
    Chen, P
    Heuer, D
    Lee, P
    Dacey, M
    Philips, A
    Minckler, D
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1173 - 1173
  • [10] Comparison of the Ahmed glaucoma valve with the Baerveldt glaucoma implant: a meta-analysis
    Wang, Yi-Wen
    Wang, Ping-Bao
    Zeng, Chao
    Xia, Xiao-Bo
    [J]. BMC OPHTHALMOLOGY, 2015, 15