Measurement of the three-dimensional point-spread function in an optical coherence tomography imaging system - art. no. 68472Q

被引:8
|
作者
Tomlins, Peter H. [1 ]
Woolliams, Peter [1 ]
Tedaldi, Matthew [1 ]
Beaumont, Andrew [1 ]
Hart, Christian [1 ]
机构
[1] Natl Phys Lab, Opt Technol Grp, Teddington TW11 0LW, Middx, England
关键词
optical coherence tomography; calibration phantom; resolution; point spread function;
D O I
10.1117/12.766576
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two significant figures of merit for optical coherence tomography (OCT) systems are the axial and transverse resolutions. Transverse resolution has been defined using the Rayleigh Criterion or from Gaussian beam optics. The axial resolution is generally defined in terms of the coherence length of a Gaussian shaped source. Whilst these definitions provide a useful mathematical reference they are somewhat abstracted from the three dimensional resolution that is encountered under practical imaging conditions. Therefore, we have developed a three-dimensional resolution target and measurement methodology that can be used to calibrate the three-dimensional resolution of OCT systems.
引用
收藏
页码:Q8472 / Q8472
页数:8
相关论文
共 50 条
  • [1] Coherence scanning interferometry: measurement and correction of three-dimensional transfer and point-spread characteristics
    Mandal, Rahul
    Coupland, Jeremy
    Leach, Richard
    Mansfield, Daniel
    [J]. APPLIED OPTICS, 2014, 53 (08) : 1554 - 1563
  • [2] Measurement of the point-spread function of a noisy imaging system
    Claxton, Christopher D.
    Staunton, Richard C.
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2008, 25 (01) : 159 - 170
  • [3] Point Spread Function Measurement and Analysis of Three Dimensional Optical Imaging System
    Li, Xiuyu
    Wen, Tao
    Hu, Zhixiong
    Wang, Hongting
    Liu, Wenli
    Hong, Baoyu
    Zhong, Chenyang
    [J]. 14TH NATIONAL CONFERENCE ON LASER TECHNOLOGY AND OPTOELECTRONICS (LTO 2019), 2019, 11170
  • [4] One-dimensional iterative algorithm for three-dimensional point-spread function engineering
    Martínez-Corral, M
    Muñoz-Escrivá, L
    Kowalczyk, M
    Cichocki, T
    [J]. OPTICS LETTERS, 2001, 26 (23) : 1861 - 1863
  • [5] Three-dimensional space-invariant point-spread function for a single lens
    Gu, Min
    [J]. Journal of the Optical Society of America A: Optics and Image Science, and Vision, 1995, 12 (07):
  • [6] Optical coherence tomography for three-dimensional imaging of skin features
    Lenderink, E
    [J]. OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING IV, PROCEEDINGS OF, 1999, 3567 : 70 - 77
  • [7] Three-dimensional Imaging of Ureter With Endoscopic Optical Coherence Tomography
    Wang, Hui
    Kang, Wei
    Zhu, Hui
    MacLennan, Gregory
    Rollins, Andrew M.
    [J]. UROLOGY, 2011, 77 (05) : 1254 - 1258
  • [8] THREE-DIMENSIONAL IMAGING OF URETER WITH ENDOSCOPIC OPTICAL COHERENCE TOMOGRAPHY
    Wang, Hui
    Kang, Wei
    Zhu, Hui
    MacLennan, Gregory
    Rollins, Andrew
    [J]. JOURNAL OF UROLOGY, 2011, 185 (04): : E923 - E923
  • [9] Three-dimensional imaging of artificial fingerprint by Optical Coherence Tomography
    Larin, Kirill V.
    Cheng, Yezeng
    [J]. BIOMETRIC TECHNOLOGY FOR HUMAN IDENTIFICATION V, 2008, 6944
  • [10] Three-dimensional multifunctional optical coherence tomography for skin imaging
    Li, En
    Makita, Shuichi
    Hong, Young-Joo
    Kasaragod, Deepa
    Sasaoka, Tomoko
    Yamanari, Masahiro
    Sugiyama, Satoshi
    Yasuno, Yoshiaki
    [J]. PHOTONIC THERAPEUTICS AND DIAGNOSTICS XII, 2016, 9689