Initial fixation and cyclic loading stability of knotless suture anchors for rotator cuff repair

被引:19
|
作者
Brown, Barrett S.
Cooper, Andrew D.
Mclff, Terence E. [1 ]
Key, Vincent H. [1 ]
Toby, E. Bruce [1 ]
机构
[1] Univ Kansas, Med Ctr, Dept Orthoped Surg, Kansas City, KS 66160 USA
关键词
D O I
10.1016/j.jse.2007.05.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study evaluated the resistance to gapping and the mode of failure for 2 knotless suture anchor systems used for rotator cuff repair compared with the performance of a conventional titanium anchor system. Eight matched pairs of fresh-frozen humeri were dissected free of all soft tissues and scanned to measure bone mineral density (BMD). The suture anchor systems tested were the TwinFix 5.0 Titanium (Smith & Nephew, Andover, MA), Bioknotless RC (DePuy Mitek, Norwood, MA), and Magnum (Opus Medical, Son Juan Capistrano, CA), and each was inserted into each humerus. Cyclic, tensile loading was applied through the suture loop for 5000 cycles, or until failure, by using a servohydraulic testing machine. Gapping distances, defined as increasing elongation of the bone/anchor/suture system, were continuously measured. Total cycles to failure and mechanism of failure were documented. Mean initial (first cycle) and final (lost cycle) gapping distances were 3.81 mm and 5.36 mm for the TwinFix 5.0, 4.02 mm and 5.34 mm for the Bioknotless RC, and 3.56 mm and 4.98 mm for the Magnum anchors. No significant difference was detected among mean gap openings (P > .05). However, the Bioknotless RC had more early failures (5) than the other 2 implants (I each), approaching significance (P = .07). Trials of the Bioknotless RC that did not fail early were found to hove significantly less gap opening than the other 2 systems for both initial (1.89 mm vs 3.82 mm for the TwinFix 5.0 and 3.56 mm for the Magnum) and final (2.00 mm vs 4.68 mm for the TwinFix 5.0 and 4.24 mm for the Magnum) gap opening. BMD was a significant predictor of initial (P = .029) and final (P = .008) gap opening, whereas the site of anchor insertion was a significant predictor of final displacement. The Opus Magnum was comparable with a conventional suture anchor, but the Mitek Bioknotless RC showed a trend toward early failure. Biomechanical analysis of knotless suture anchor systems can demonstrate trends among implants in an experimental setting. Knowledge of these trends could influence implant selection.
引用
收藏
页码:313 / 318
页数:6
相关论文
共 50 条
  • [1] Suture anchor offers knotless fixation in rotator cuff repair
    不详
    [J]. ADVANCED MATERIALS & PROCESSES, 2013, 171 (09): : 6 - 6
  • [2] Suture Slippage in Knotless Suture Anchors as a Potential Failure Mechanism in Rotator Cuff Repair
    Wieser, Karl .
    Farshad, Mazda
    Vlachopoulos, Lazaros
    Ruffieux, Kurt
    Gerber, Christian
    Meyer, Dominik C.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2012, 28 (11): : 1622 - 1627
  • [3] Biomechanical Stability of Knotless Suture Anchors Used in Rotator Cuff Repair in Healthy and Osteopenic Bone
    Pietschmann, Matthias F.
    Guelecyuez, Mehmet F.
    Fieseler, Sybille
    Hentschel, Markus
    Rossbach, Bjoern
    Jansson, Volkmar
    Mueller, Peter E.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (08): : 1035 - 1044
  • [4] Rotator Cuff Sparing Arthroscopic SLAP Repair With Knotless All-Suture Anchors
    Dekker, Travis J.
    Lacheta, Lucca
    Goldenberg, Brandon
    Grantham, W. Jeffrey
    Millett, Peter J.
    [J]. ARTHROSCOPY TECHNIQUES, 2019, 8 (09): : E993 - E998
  • [5] Knotless Single-row Rotator Cuff Repair: A Comparative Biomechanical Study of 2 Knotless Suture Anchors
    Efird, Chad
    Traub, Shaun
    Baldini, Todd
    Rioux-Forker, Dana
    Spalazzi, Jeffrey P.
    Davisson, Twana
    Hawkins, Monica
    McCarty, Eric
    [J]. ORTHOPEDICS, 2013, 36 (08) : E1033 - E1037
  • [6] Double row fixation of rotator cuff sutures with knotless anchors
    Ingenhoven, E.
    [J]. ARTHROSKOPIE, 2009, 22 (04) : 333 - 335
  • [7] Suture anchors in arthroscopic rotator cuff repair
    George, MS
    Kuhn, JE
    [J]. OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2004, 12 (04) : 210 - 214
  • [8] Biomechanical testing of a new knotless suture anchor compared with established anchors for rotator cuff repair
    Pietschmann, Matthias F.
    Froehlich, Valerie
    Ficklscherer, Andreas
    Wegener, Bernd
    Jansson, Volkmar
    Mueller, Peter E.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (04) : 642 - 646
  • [9] Contact area and pressure in suture bridge rotator cuff repair using knotless lateral anchors
    Marc Tompkins
    Keith O. Monchik
    Matthew J. Plante
    Braden C. Fleming
    Paul D. Fadale
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 1788 - 1793
  • [10] Contact area and pressure in suture bridge rotator cuff repair using knotless lateral anchors
    Tompkins, Marc
    Monchik, Keith O.
    Plante, Matthew J.
    Fleming, Braden C.
    Fadale, Paul D.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (10) : 1788 - 1793