Optimal Sizing and Assessment of a Renewable Rich Standalone Hybrid Microgrid Considering Conventional Dispatch Methodologies

被引:10
|
作者
Ishraque, Md Fatin [1 ,2 ]
Shezan, Sk A. [3 ]
Rana, Md Sohel [2 ]
Muyeen, S. M. [4 ]
Rahman, Akhlaqur [3 ]
Paul, Liton Chandra [1 ]
Islam, Md Shafiul [5 ]
机构
[1] Pabna Univ Sci & Technol, Dept Elect Elect & Commun Engn, Pabna 6600, Bangladesh
[2] Rajshahi Univ Engn & Technol, Dept Elect & Elect Engn, Rajshahi 6204, Bangladesh
[3] Engn Inst Technol, Dept Elect Engn & Ind Automat, Melbourne, Vic 3283, Australia
[4] Qatar Univ, Dept Elect Engn, Doha 2713, Qatar
[5] Varendra Univ, Dept EEE, Rajshahi 6204, Bangladesh
关键词
techno-economic study; dispatch methodology; renewable; optimization; hybrid microgrid; power system response; DYNAMIC ECONOMIC-DISPATCH; PERFORMANCE ANALYSIS; STRATEGY; OPTIMIZATION; SYSTEM; ENERGY; ALGORITHM; OPERATION; DC; AC;
D O I
10.3390/su132212734
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents an evaluation of the optimized design of an off-grid hybrid microgrid for alternative load dispatch algorithms with the determination of the most optimal sizing of each equipment, analyzing the voltage and frequency outputs and various costs of the proposed microgrids. Kushighat and Rajendro Bazar, two geographical locations in Bangladesh have been taken as test sites. The proposed microgrids incorporating diesel generator, renewable resources, storage device, and 23.31 kW of demand have been optimized for five conventional load dispatch methodologies: HOMER predictive dispatch, Load Following, Generator Order, Cycle Charging, and Combined Dispatch to reduce the system's net present cost, gas discharge and cost of energy. HOMER (Hybrid Optimization of Multiple Electric Renewables) software has been used for the analysis to determine the optimal sizes and costing and the voltage-frequency performances of the microgrids are analyzed using MATLAB/Simulink. From our analysis, load following is determined as the superior approach with a minimum operating cost of 3738 USD, net present cost of 152,023 USD, CO2 discharge of 3375 kg/year and cost of energy of 0.208 USD /kWh along with a steady voltage-frequency output. Combined dispatch is determined as the worst strategy for the proposed microgrids with the highest energy cost of 0.532 USD /kWh, the operational cost of 15,394 USD, net present cost of 415,030 USD, and high CO2 discharge. At the end of this work, a comparative analysis between the proposed design, another hybrid, and traditional generation plant is also presented. The findings of this work will be appropriate for any location with an identical demand profile and meteorological estate.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Optimal Sizing of an Islanded Hybrid Microgrid Considering Alternative Dispatch Strategies
    Shezan, Sk A.
    Hasan, Kazi N.
    Datta, Manoj
    [J]. 2019 29TH AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2019,
  • [2] Optimal Participation of Hybrid Renewable Energy Sources in Standalone Microgrid
    Nayak, Manas Ranjan
    Saha, Manoj
    Nayak, Chinmay Kumar
    [J]. INTELLIGENT COMPUTING, INFORMATION AND CONTROL SYSTEMS, ICICCS 2019, 2020, 1039 : 144 - 153
  • [3] Optimal sizing of standalone rural microgrid for sustainable electrification with renewable energy resources
    Kamal, Md. Mustafa
    Ashraf, Imtiaz
    Fernandez, Eugen
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2023, 88
  • [4] Optimal Sizing of Standalone Hybrid Microgrid Using Artificial Jellyfish Search
    Ali, Ashraf Fathy
    Gouda, Eid A.
    Elsayes, Mohamed Adel
    Cao, Di
    Hu, Weihao
    Abulanwar, Sayed
    [J]. 2022 4TH ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM (AEEES 2022), 2022, : 171 - 176
  • [5] Optimal power dispatch considering load and renewable generation uncertainties in an AC-DC hybrid microgrid
    Maulik, Avirup
    Das, Debapriya
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (07) : 1164 - 1176
  • [6] Optimal sizing and assessment of a hybrid energy based AC microgrid
    Madhura, S.
    Boddapati, Venkatesh
    [J]. MATERIALS TODAY-PROCEEDINGS, 2022, 49 : 326 - 332
  • [7] Sizing and Modeling of a Standalone Hybrid Renewable Energy System
    Al-Falahi, Monaaf D. A.
    Nimma, Kutaiba Sabah
    Jayasinghe, S. D. G.
    Enshaei, Hossein
    [J]. 2016 IEEE 2ND ANNUAL SOUTHERN POWER ELECTRONICS CONFERENCE (SPEC), 2016,
  • [8] Effect of a Storage System in a Microgrid with EDR and Economic Dispatch Considering Renewable and Conventional Energy Sources
    Aguilar-Mejia, O.
    Minor-Popocatl, H.
    Caballero-Morales, O. S.
    Miranda-Perez, A. F.
    [J]. SUSTAINABILITY, 2024, 16 (02)
  • [9] Optimal sizing and operation of microgrid considering renewable energy uncertainty based on scenario generation
    Hu, Dingding
    Fan, Yinchao
    Shao, Wenbin
    [J]. Journal of Energy Storage, 2025, 109
  • [10] Optimal sizing and operation for microgrid with renewable energy considering two types demand response
    Sugimura, Makoto
    Gamil, Mahmoud M.
    Akter, Homeyra
    Krishna, Narayanan
    Abdel-Akher, Mamdouh
    Mandal, Paras
    Senjyu, Tomonobu
    [J]. JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2020, 12 (06)