Beat-to-beat Heart Rate Detection Based on Seismocardiogram Using BiLSTM Network

被引:0
|
作者
Chen, Yuhang [1 ]
Xu, WenChang [2 ]
Zhu, Wenliang [1 ]
Ma, Gang [1 ]
Chen, Xiaohe [2 ]
Wang, Lirong [3 ]
机构
[1] Univ Sci & Technol China, Suzhou Inst Biomed Engn & Technol, Suzhou, Peoples R China
[2] Suzhou Inst Biomed Engn & Technol, Suzhou, Peoples R China
[3] Soochow Univ, Sch Elect & Informat Engn, Suzhou, Peoples R China
关键词
Seismocardiogram; Electrocardiogram; BiLSTM network; cardiac monitoring; accelerometer;
D O I
10.1109/TRUSTCOM53373.2021.00216
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The detection of consecutive cardiac cycles plays an important role in the daily monitoring of cardiovascular diseases. The Seismocardiogram (SCG) signal measures the cardiac-induced vibrations and is suitable for continuously tracking since it can be measured in a non-invasive fashion. In this paper, a beat-to-beat heart rate detection method based on low-frequency SCG signal using BiLSTM network is proposed. The regression model to predict Electrocardiogram (ECG) from SCG was trained on CEBS dataset and a 5-fold cross-validation method was adopted. The RMSE of the predicted ECG signal and ECG signal was 0.0367. The sensitivity and precision achieved 0.97 and 0.98 separately and the Spearman Correlation was 0.98. This work shows promise for the proposed SCG based methodology to be used as an alternative to ECG for continuous beat-to-beat heart rate monitoring.
引用
收藏
页码:1503 / 1507
页数:5
相关论文
共 50 条
  • [1] Beat-to-beat heart rate detection by smartphone accelerometers
    Landreani, F.
    Martin-Yebra, A.
    Casellato, C.
    Frigo, C.
    Pavan, E.
    Migeotte, P. -F.
    Caiani, E. G.
    [J]. EUROPEAN HEART JOURNAL, 2016, 37 : 859 - 860
  • [2] An online PPGI approach for camera based heart rate monitoring using beat-to-beat detection
    Bloecher, Timon
    Schneider, Johannes
    Schinle, Markus
    Stork, Wilhelm
    [J]. 2017 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS), 2017,
  • [3] Assessment of beat-to-beat heart rate detection method using a camera as contactless sensor
    Iozzia, L.
    Cerina, L.
    Mainardi, L. T.
    [J]. 2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 521 - 524
  • [4] A BEAT-TO-BEAT HEART-RATE METER
    NIJHAWAN, SC
    SHARMA, VK
    KHANDPUR, RS
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (01) : 42 - 44
  • [5] Adaptive Beat-to-Beat Heart Rate Estimation in Ballistocardiograms
    Brueser, Christoph
    Stadlthanner, Kurt
    de Waele, Stijn
    Leonhardt, Steffen
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (05): : 778 - 786
  • [6] DIGITAL BEAT-TO-BEAT HEART-RATE METER
    VOULGARIS, NC
    BAILAS, AA
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1984, 22 (02) : 181 - 183
  • [7] Feasibility Study for Beat-to-beat Heart Rate detection by Smartphone's Accelerometers
    Landreani, Federica
    Martin-Yebra, Alba
    Casellato, Claudia
    Pavan, Esteban
    Frigo, Carlo
    Migeotte, Pierre-Francois
    Caiani, Enrico G.
    [J]. 2015 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2015,
  • [8] Beat-to-beat adaptation of QT interval to heart rate
    Pueyo, Esther
    Malik, Marek
    Laguna, Pablo
    [J]. 2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 2475 - 2478
  • [9] Beat-to-beat Heart Rate detection by Smartphone's Accelerometers: validation with ECG
    Landreani, F.
    Martin-Yebra, A.
    Casellato, C.
    Frigo, C.
    Pavan, E.
    Migeotte, P-F
    Caiani, E. G.
    [J]. 2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 525 - 528
  • [10] An algorithm for beat-to-beat heart rate detection from the BCG based on the continuous spline wavelet transform
    Alvarado-Serrano, Carlos
    Samuel Luna-Lozano, Pablo
    Pallas-Areny, Ramon
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2016, 27 : 96 - 102