Seismic Performance of FRP-Confined Circular RC Columns

被引:0
|
作者
Wang, Z. Y. [1 ]
Wang, D. Y. [1 ]
Sheikh, S. A. [2 ]
Liu, J. T. [2 ]
机构
[1] Harbin Inst Technol, Sch Civil Engn, Harbin 150006, Peoples R China
[2] Univ Toronto, Dept Civil Engn, Toronto, ON M5S 1A1, Canada
关键词
RETROFIT;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To investigate the seismic performance of FRP-confined circular RC columns with high axial compression ratio, six third-scaled columns confined with Carbon Fiber-reinforced Polymer (CFRP) at plastic hinge region and two control columns were tested under constant axial load and cyclic lateral force. The maximum axial compression ratio (P/f'(c)A(g)) was 0.65 and the shear span ratio was 3.5. Test results demonstrated marked improvement in the ductility and energy dissipation of the columns due to CFRP wrapping at plastic hinge region. The study also found that the contribution of hoops to confining effect should not be ignored under the condition of high axial compression ratio. To accurately simulate the seismic performance and obtain the hysteretic shear-deformation curves of FRP-confined columns, a nonlinear analytical procedure was developed using fiber model based on OpenSees (Open System for Earthquake Engineering Simulation). A stress-strain model which considers the confining effects of both the internal hoops and external CFRP jacketing was used. The analytical results indicated that inclusion of the both confining effects results in better simulation of the test results from this and other studies. But, if the axial compression ratio is less than 0.3, the analytical results are not affected even considering the contributions of hoops. The lateral loading capacity of columns begins to decrease when the axial compression ratio exceeds 0.6 and when the length of wrapped CFRP at the plastic hinge region exceeds 1.2D (D is the diameter of columns), the seismic performance could be improved to a level equivalent to fully wrapped columns.
引用
收藏
页码:810 / +
页数:3
相关论文
共 50 条
  • [1] Slenderness Limit for Short FRP-Confined Circular RC Columns
    Jiang, T.
    Teng, J. G.
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2012, 16 (06) : 650 - 661
  • [2] Behavior and Design of Slender FRP-Confined Circular RC Columns
    Jiang, T.
    Teng, J. G.
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2013, 17 (04) : 443 - 453
  • [3] Theoretical model for slender FRP-confined circular RC columns
    Jiang, T.
    Teng, J. G.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2012, 32 : 66 - 76
  • [4] Behavior of FRP-Confined Circular RC Columns under Eccentric Compression
    Xing, L.
    Lin, G.
    Chen, J. F.
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2020, 24 (04)
  • [5] Behavior of FRP-Confined Circular RC Columns under Eccentric Compression
    Xing, L.
    Lin, G.
    Chen, J.F.
    [J]. Journal of Composites for Construction, 2020, 24 (04):
  • [6] Fire resistance of RC and FRP-confined RC columns
    Han, L. H.
    Zheng, Y. Q.
    Teng, J. G.
    [J]. MAGAZINE OF CONCRETE RESEARCH, 2006, 58 (08) : 533 - 546
  • [7] Modelling plastic hinge of FRP-confined RC columns
    Yuan, Fang
    Wu, Yu-Fei
    Li, Chun-Qing
    [J]. ENGINEERING STRUCTURES, 2017, 131 : 651 - 668
  • [8] Seismic performance of FRP-confined steel-reinforced RAC columns
    Ren, F. M.
    Tian, S. Y.
    Ma, W.
    Chen, G. M.
    Tao, Y.
    Xie, P.
    [J]. COMPOSITE STRUCTURES, 2022, 282
  • [9] Seismic performance assessment of flexure-dominate FRP-confined RC columns using plastic rotation angle
    Li, Benben
    Harries, Kent A.
    [J]. ENGINEERING STRUCTURES, 2018, 172 : 453 - 471
  • [10] FRP-confined circular columns subjected to eccentric loading
    Csuka, Bernat
    Kollar, Laszlo P.