Quantitative dobutamine stress echocardiography for the early detection of cardiac allograft vasculopathy in heart transplant recipients

被引:36
|
作者
Eroglu, E. [1 ]
Dhooge, J. [1 ]
Sutherland, G. R. [1 ]
Marciniak, A. [1 ]
Thijs, D. [1 ]
Droogne, W. [1 ]
Herbots, L. [1 ]
Van Cleemput, J. [1 ]
Claus, P. [1 ]
Bijnens, B. [1 ]
Vanhaecke, J. [1 ]
Rademakers, F. [1 ]
机构
[1] Catholic Univ Louvain, Dept Cardiovasc Dis, B-3000 Louvain, Belgium
关键词
D O I
10.1136/hrt.2007.119693
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A non-invasive method to detect the presence of cardiac allograft vasculopathy (CAV) remains an important goal in clinical cardiology. Objective: To assess the value of quantitative dobutamine stress echocardiography (DSE) for the early detection of CAV. Methods: 42 heart transplant recipients underwent DSE with acquisition of both conventional two-dimensional and colour tissue Doppler data. All studies were analysed conventionally and quantitatively using regional deformation parameters - that is, peak systolic longitudinal strain (epsilon(peak) (sys)), strain rate (SRpeak (sys)) and post-systolic strain index. Myocardial segments were classified as normal, mildly abnormal or severely abnormal based on correlative angiographic findings. Results: At baseline, epeak sys was significantly lower in severely abnormal segments than in normal ones. However, at peak stress, epeak sys was able to separate three groups of segments. Receiver operating characteristic analysis showed an SRpeak sys response of <0.5/s to identify patients with CAV with a sensitivity of 88%, specificity of 85% and a negative predictive value of 92%. Conclusion: Regional myocardial function is impaired in heart transplant recipients with CAV even when the disease is considered to be non-significant on conventional angiography. Systolic deformation parameters tended to detect the existence of CAV more accurately than conventional visual DSE assessment. Strain rate imaging during stress can therefore safely be used as a non-invasive screening test for detecting CAV in heart transplant recipients.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A prospective study of dobutamine stress echocardiography for the assessment of cardiac allograft vasculopathy in pediatric heart transplant recipients
    Dipchand, Anne I.
    Bharat, Winston
    Manlhiot, Cedric
    Safi, Mina
    Lobach, Natalia E.
    McCrindle, Brian W.
    PEDIATRIC TRANSPLANTATION, 2008, 12 (05) : 570 - 576
  • [2] Diagnostic Accuracy of Dobutamine Stress Echocardiography for Detection of Cardiac Allograft Vasculopathy in Orthotopic Heart Transplant Patients
    Mahmoodurrahman, Mohammed
    Marek, Josef
    Juhardeen, Hamzah Ruxshan
    Al Otaibi, Talal
    Cury Salemi, Vera Maria
    Echahidi, Najmeddine
    Al Buraiki, Jehad
    Fadel, Bahaa M.
    Mohty, Dania
    JOURNAL OF THE SAUDI HEART ASSOCIATION, 2021, 33 (04) : 279 - 285
  • [3] Dipyridamole stress echocardiography for the diagnosis of cardiac allograft vasculopathy in heart transplant recipients
    Alvarez Pichel, I.
    Fernandez Cimadevilla, O. C.
    De la Hera Galarza, J. M.
    Martin Fernandez, M.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2019, 23 (04) : 1386 - 1387
  • [4] Dobutamine stress echocardiography in the assessment of cardiac allograft vasculopathy in asymptomatic recipients
    Sade, L. Elif
    Sezgin, A.
    Eroglu, S.
    Bozbas, H.
    Ulucam, M.
    Muederrisoglu, H.
    TRANSPLANTATION PROCEEDINGS, 2008, 40 (01) : 267 - 270
  • [5] Dobutamine Stress Echocardiography to Detect Early Cardiac Allograft Vasculopathy
    Clerkin, K. J.
    Garan, A. R.
    Farr, M. A.
    Restaino, S. W.
    Latif, F.
    Yuzefpolskaya, M.
    Colombo, P. C.
    Mancini, D. M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S201 - S201
  • [6] Dual-Source CT Coronary Angiogram in Heart Transplant Recipients in Comparison With Dobutamine Stress Echocardiography for Detection of Cardiac Allograft Vasculopathy
    Mastrobuoni, Stefano
    Bastarrika, Gorka
    Ubilla, Matias
    Castano, Sara
    Azcarate, Pedro
    Barrero, Eduardo Alegria
    Castellano, Jose Maria
    Herreros, Jesus
    Rabago, Gregorio
    TRANSPLANTATION, 2009, 87 (04) : 587 - 590
  • [7] Diagnostic accuracy of dobutamine stress echocardiography in the detection of cardiac allograft vasculopathy in heart transplant recipients: A systematic review and meta-analysis study
    Elkaryoni, Ahmed
    Abu-Sheasha, Ghada
    Altibi, Ahmed M.
    Hassan, Adil
    Ellakany, Karim
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (03): : 528 - 536
  • [8] Dobutamine stress echocardiography in the assessment of graft vasculopathy in asymptomatic cardiac allograft recipients
    Elif, Sade Leyla
    Atilla, Sezgin
    Serpil, Eroglu
    Huseyin, Bozbas
    Melek, Ulucam
    Haldun, Muderrisoglu
    CARDIOVASCULAR DRUGS AND THERAPY, 2007, 21 : S59 - S59
  • [9] Dobutamine stress echocardiography is inadequate to detect early cardiac allograft vasculopathy
    Clerkin, Kevin J.
    Farr, Maryjane A.
    Restaino, Susan W.
    Ali, Ziad A.
    Mancini, Donna M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (08): : 1040 - 1041
  • [10] Diagnostic Accuracy of Dobutamine Stress Echocardiography in the Detection of Cardiac Allograft Vasculopathy in Heart Transplant Recipients: A Systematic Review and Meta-Analysis Study.
    Elkaryoni, Ahmed
    Altibi, Ahmed M.
    Hassan, Adil
    Elgebaly, Ahmed
    Elsabbagh, Eman M.
    Nanda, Navin C.
    CIRCULATION, 2018, 138