Application of Infrared Lamp Array in the Thermal Balance Test of SINOSAT-2

被引:0
|
作者
Liu Shouwen [1 ]
Pei Yifei [2 ]
Sun Laiyan [1 ]
机构
[1] Beijing Univ Aeronaut & Astronaut, Sch Aero Sci & Eng, Beijing 100083, Peoples R China
[2] Beijing Inst Spacecraft Environm Engn, Beijing 100094, Peoples R China
关键词
D O I
10.1117/12.855450
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Infrared lamp array is applied as absorbed heat flux of south and north surface OSR in the thermal balance test of communication satellite Sinosat-2. In thermal balance test, the accuracy of heat flux simulation is one of the key technologies. This paper will introduce the heat flux simulation technology. The uniformity degree is 7.8% for the 90% area of north lamp array above. Meanwhile, the uniformity degree is 7.9% for the 90% area of south lamp array below, which satisfy the requirement of test. Monitored Background Radiometer is used to actually measure the amount of energy absorbed by the N/S OSR surface. The method designed in this work satisfies the requirement of test, which simulates the external heat flux by infrared lamp array.
引用
收藏
页数:5
相关论文
共 32 条
  • [1] Infrared lamp array simulation technology used during satellite thermal testing
    Jing, Wang
    Shouwen, Liu
    Yifei, Pei
    World Academy of Science, Engineering and Technology, 2010, 70 : 707 - 709
  • [2] Infrared lamp array simulation technology used during satellite thermal testing
    Jing, Wang
    Shouwen, Liu
    Yifei, Pei
    World Academy of Science, Engineering and Technology, 2010, 69 : 707 - 709
  • [3] Research on spectral pattern of infrared lamp for thermal vacuum test of spacecraft
    Liu S.-W.
    Pei Y.-F.
    Sun L.-Y.
    Yuhang Xuebao/Journal of Astronautics, 2010, 31 (01): : 254 - 258
  • [4] Infrared lamp array simulation technology used during satellite thermal testing
    Wang, Jing
    Liu, Shouwen
    Pei, Yifei
    World Academy of Science, Engineering and Technology, 2010, 45 : 708 - 710
  • [5] Failure Analysis and remedial measures of Infrared Lamp for spacecraft Thermal Test
    An Wanqing
    Han Fang
    Wen Jing
    Ge Zheyang
    Liang Shuo
    2018 EIGHTH INTERNATIONAL CONFERENCE ON INSTRUMENTATION AND MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC 2018), 2018, : 1051 - 1056
  • [6] THERMAL BALANCE TEST CHAMBERS AND THEIR APPLICATION TO SPACECRAFT
    ACTON, EWV
    BREDDY, NC
    VACUUM, 1968, 18 (03) : 130 - &
  • [7] EVALUATION OF THE INFRARED TEST METHOD FOR THE OLYMPUS THERMAL BALANCE TESTS
    DONATO, M
    GREEN, J
    STPIERRE, D
    REEVES, M
    JOURNAL OF ENVIRONMENTAL SCIENCES, 1987, 30 (03): : 45 - 49
  • [8] A test method of thermal time constant for uncooled infrared focal plane array
    Liu Z.
    Zhao S.
    Zhao Z.
    Li Y.
    Zheng X.
    Zhang L.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2019, 48 (12):
  • [9] Test for mechanical cooler induced noise in a low noise infrared 2-D detector array:: Space borne application for sensing wave structure in thermal CO2 emission
    Kumer, JB
    Rairden, R
    Roche, AE
    Kotsubo, V
    Nast, TC
    Olson, JR
    SENSORS AND CAMERA SYSTEMS FOR SCIENTIFIC, INDUSTRIAL, AND DIGITAL PHOTOGRAPHY APPLICATIONS II, 2001, 4306 : 1 - 12
  • [10] Application of a two source energy balance model coupled with satellite based soil moisture and thermal infrared data
    Song, Lisheng
    Xu, Yanhao
    Liddell, Michael
    Cui, Yaokui
    Liu, Shaomin
    Xu, Peipei
    ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2023, 204 : 15 - 26