Decrease of Coronal Optic Nerve Sheath Diameter is Associated With Postoperative Cognitive Decline in Patients Undergoing Carotid Endarterectomy

被引:4
|
作者
Zhang, Li-Min [1 ]
Li, Yan [1 ]
Zhang, Yun-Ting [2 ]
Zhang, Bao-Xu [2 ]
Wang, Jing-Zhou [2 ]
Zhang, Dong-Xue [3 ]
机构
[1] Cangzhou Cent Hosp, Dept Anesthesiol, Cangzhou, Peoples R China
[2] Cangzhou Cent Hosp, Dept Neurosurg, Cangzhou, Peoples R China
[3] Cangzhou Cent Hosp, Dept Gerontol, Cangzhou, Peoples R China
关键词
carotid endarterectomy; cognitive dysfunction; optic nerve sheath diameter; ultrasonography; anesthesia; CEREBRAL HYPERPERFUSION; SEVOFLURANE; IMPAIRMENT; DYSFUNCTION; PRESSURE; IMPROVEMENT; TOMOGRAPHY; ANESTHESIA; BYPASS;
D O I
10.1053/j.jvca.2020.11.006
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: Patients undergoing carotid endarterectomy (CEA) have a significant possibility of developing postoperative cognitive decline (POCD). POCD after surgery could be result from cerebral hypotension induced by cross-clamping or postoperative hyperperfusion. Optic nerve sheath diameter (ONSD) exhibits an excellent correlation with invasive intracranial pressure monitoring, Here, the authors explored the risk factors of POCD in patients undergoing CEA, paying close attention to ONSD to test the hypothesis that decrease of coronal ONSD was related to the incidence of POCD. Design: Observational retrospective review. Setting: Single tertiary academic center. Participants: One hundred sixteen patients undergoing CEA from January 1, 2019 to December 31, 2019. Intervention: None. Measurements and Main Results: A multivariate logistic regression, scatter diagrams, and a receiver operating curve were used to evaluate the ability to predict POCD though the change in coronal ONSD. This study ultimately enrolled 84 patients and the incidence of POCD within postoperative two days was 28.6%. Decrease of coronal ONSD (odds ratio [OR], 0.438; 95% confidence interval [CI] 0.217-0.881; p = 0.021) and total intravenous anesthesia (TIVA) (OR, 25.541, 95% CI 2.100-310.614, p = 0.011) were independent risk factors for POCD. Changes in coronal ONSD had an area under the curve to distinguish POCD of 0.716 (95% CI 0.531-0.902). Using a cutoff of 0.05 cm, changes of coronal ONSD had a sensitivity of 66.7% and specificity of 66.7%. Conclusions: Decrease of coronal ONSD, measured by ultrasonography and TIVA, were associated with POCD. Change in coronal ONSD was a moderate predictor of incidence of POCD. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:2355 / 2362
页数:8
相关论文
共 50 条
  • [1] Assessment of Optic Nerve Sheath Diameter in Patients Undergoing Epiduroscopy
    Tire, Yasin
    Coven, Ilker
    Cebeci, Zubeyir
    Yilmaz, Ali
    Basaran, Betul
    MEDICAL SCIENCE MONITOR, 2019, 25 : 6911 - 6916
  • [2] Postoperative cerebral hyperperfusion associated with impaired cognitive function in patients undergoing carotid endarterectomy
    Ogasawara, K
    Yamadate, K
    Kobayashi, M
    Endo, H
    Fukuda, T
    Yoshida, K
    Terasaki, K
    Inoue, T
    Ogawa, A
    JOURNAL OF NEUROSURGERY, 2005, 102 (01) : 38 - 44
  • [3] Coronal Axis Measurement of the Optic Nerve Sheath Diameter Reply
    Amini, Richard
    Stolz, Lori
    Patanwala, Asad
    Adhikari, Srikar
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (05) : 1073 - 1074
  • [4] Elevation in optic nerve sheath diameter due to the pneumoperitoneum and Trendelenburg is associated to postoperative nausea, vomiting and headache in patients undergoing laparoscopic hysterectomy
    Yilmaz, Gulseren
    Akca, Aysu
    Kiyak, Huseyin
    Salihoglu, Ziya
    MINERVA ANESTESIOLOGICA, 2020, 86 (03) : 270 - 276
  • [5] Cognitive testing in patients undergoing carotid endarterectomy
    Irvine, CD
    Gardner, FV
    Davies, AH
    Lamont, PM
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 15 (03) : 195 - 204
  • [6] Optic nerve sheath diameter assessment in obese patients undergoing robotic pelvic surgery
    Vitiello, Livio
    De Bernardo, Maddalena
    Rosa, Nicola
    INDIAN JOURNAL OF ANAESTHESIA, 2019, 63 (06) : 507 - +
  • [7] Coronal Axis Measurement of the Optic Nerve Sheath Diameter Using a Linear Transducer
    Amini, Richard
    Stolz, Lori A.
    Patanwala, Asad E.
    Adhikari, Srikar
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (09) : 1607 - 1612
  • [8] Correlation of visual axis and coronal axis measurements of the optic nerve sheath diameter
    Blehar, David J.
    Gaspari, Romolo J.
    Montoya, Anthony
    Calderon, Richard
    JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (03) : 407 - 411
  • [9] Postoperative blood pressure in patients undergoing eversion carotid endarterectomy with or without resection of the carotid sinus nerve
    K. Linni
    M. Aspalter
    D. Neureiter
    W. Hitzl
    H. Magometschnigg
    T. Hölzenbein
    European Surgery, 2014, 46 : 244 - 249
  • [10] Postoperative blood pressure in patients undergoing eversion carotid endarterectomy with or without resection of the carotid sinus nerve
    Linni, K.
    Aspalter, M.
    Neureiter, D.
    Hitzl, W.
    Magometschnigg, H.
    Hoelzenbein, T.
    EUROPEAN SURGERY-ACTA CHIRURGICA AUSTRIACA, 2014, 46 (06): : 244 - 249