Determination of the Her-2/neu Gene Amplification Status in Cytologic Breast Cancer Specimens Using Automated Silver-enhanced In-situ Hybridization (SISH)

被引:30
|
作者
Fritzsche, Florian Rudolf [1 ,2 ]
Bode, Peter K. [1 ]
Moch, Holger [1 ]
Kristiansen, Glen [1 ]
Varga, Zsuzsanna [1 ]
Bode, Beata [1 ]
机构
[1] Univ Zurich Hosp, Inst Surg Pathol, Div Cytol, CH-8091 Zurich, Switzerland
[2] Univ Oxford, Oxford Branch, Ludwig Inst Canc Res, Oxford, England
关键词
Her-2; SISH; FISH; breast cancer; cytology; HER2; RECEPTOR; CARCINOMA; BIOPSY; GUIDELINES; FISH;
D O I
10.1097/PAS.0b013e3181e70e15
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Silver-enhanced in-situ hybridization (SISH) is an emerging tool for the determination of the Her-2/neu amplification status in breast cancer. SISH is technically comparable to fluorescence in-situ hybridization (FISH) but does not require a fluorescence microscope for its interpretation. Although recent studies on histologic evaluations of SISH are promising, we aimed to evaluate its performance on 71 cytologic breast cancer specimens with the new combined Her-2/Chr17 probe. Her-2/neu status as routinely determined by FISH was available for all patients. We found SISH signals in cytologic cell blocks and smear specimens easy to evaluate in most cases. Small numbers of tumor cells and difficulties in identifying tumor cells in lymphocyte-rich backgrounds were limiting factors. Her-2/neu status, as determined by Her-2/Chr17 SISH, was basically identical to the results of the corresponding FISH. The discrepancies were mainly owing to the heterogeneity of Her-2/neu amplification in the tumor tissue. Interobserver agreement for the SISH evaluation was high (kappa value: 0.972). We conclude that Her-2/Chr17 SISH is a useful and accurate method for the evaluation of the Her-2/neu gene amplification status in cytologic breast cancer specimens, particularly in metastatic breast cancer lesions. The advantages of signal permanency and bright-field microscopic result interpretation make this technique an attractive alternative to the current FISH-based gold standard.
引用
收藏
页码:1180 / 1185
页数:6
相关论文
共 50 条
  • [1] HER-2/Neu Status Can Be Reliably Determined in Cytologic Breast Cancer Specimens Using Bright-Field Microscopy and Silver In-Situ Hybridization (SISH)
    Ghorab, Z.
    Saad, R. S.
    Noy, S.
    Hanna, W. M.
    Nofech-Mozes, S.
    LABORATORY INVESTIGATION, 2011, 91 : 91A - 91A
  • [2] HER-2/Neu Status Can Be Reliably Determined in Cytologic Breast Cancer Specimens Using Bright-Field Microscopy and Silver In-Situ Hybridization (SISH)
    Ghorab, Z.
    Saad, R. S.
    Noy, S.
    Hanna, W. M.
    Nofech-Mozes, S.
    MODERN PATHOLOGY, 2011, 24 : 91A - 91A
  • [3] Evaluation of automated silver-enhanced in situ hybridization (SISH) for detection of HER2 gene amplification in breast carcinoma excision and core biopsy specimens
    Shousha, S.
    Peston, D.
    Amo-Takyi, B.
    Morgan, M.
    Jasani, B.
    HISTOPATHOLOGY, 2009, 54 (02) : 248 - 253
  • [4] Automated accelerated silver in-situ hybridization (SISH™) for detection of HER2 gene amplification in breast carcinoma
    Papouchado, B. G.
    Downs-Kelly, E.
    Pestic-Dragovich, L.
    Hood, S.
    Pettay, J. D.
    Myles, J.
    Loftus, M.
    Prescott, N.
    Grogan, T.
    Roche, P. C.
    McElhinny, A. S.
    Dabbs, D. J.
    Hanna, W. M.
    Dietel, M.
    Hicks, D. G.
    Alsabeh, R.
    Powell, W. C.
    Tubbs, R. R.
    LABORATORY INVESTIGATION, 2007, 87 : 44A - 44A
  • [5] Automated accelerated silver in-situ hybridization (SISH™) for detection of HER2 gene amplification in breast carcinoma
    Papouchado, B. G.
    Downs-Kelly, E.
    Pestic-Dragovich, L.
    Hood, S.
    Pettay, J. D.
    Myles, J.
    Loftus, M.
    Prescott, N.
    Grogan, T.
    Roche, P. C.
    McElhinny, A. S.
    Dabbs, D. J.
    Hanna, W. M.
    Dietel, M.
    Hicks, D. G.
    Alsabeh, R.
    Powell, W. C.
    Tubbs, R. R.
    MODERN PATHOLOGY, 2007, 20 : 44A - 44A
  • [6] Comparison of automated silver enhanced in situ hybridization (SISH) and fluorescent in situ hybridization (FISH) for assessment of Her2/neu gene status in invasive breast carcinomas
    Kahn, H. J.
    Ghorab, Z.
    Kwok, K.
    Hanna, W.
    MODERN PATHOLOGY, 2008, 21 : 40A - 40A
  • [7] Comparison of automated silver enhanced in situ hybridization (SISH) and fluorescent in situ hybridization (FISH) for assessment of her2/neu gene status in invasive breast carcinomas
    Kahn, H. J.
    Ghorab, Z.
    Kwok, K.
    Hanna, W.
    LABORATORY INVESTIGATION, 2008, 88 : 40A - 40A
  • [8] Silver-enhanced in situ hybridisation (SISH) detection assay for HER2 gene status determination in breast carcinoma
    Patakiouta, F.
    Koumpanaki, M.
    Anestakis, D.
    Zafeiriou, G.
    Paraskevopoulos, P.
    Papakotoulas, P.
    Papazisis, T. K.
    Bousoulegas, A.
    VIRCHOWS ARCHIV, 2009, 455 : 103 - 103
  • [9] HER-2/neu gene amplification status in prostatic cancer (PC) by fluorescence in-situ hybridization (FISH).
    Ross, JS
    Sheehan, CE
    HaynerBuchan, AM
    Ambros, RA
    Kallakury, BVS
    Kaufman, R
    Fisher, HAG
    Muraca, PJ
    LABORATORY INVESTIGATION, 1997, 76 (01) : 501 - 501
  • [10] HER-2/neu gene amplification status in prostate cancer by fluorescence in situ hybridization
    Ross, JS
    Sheehan, C
    HaynerBuchan, AM
    Ambros, RA
    Kallakury, BVS
    Kaufman, R
    Fisher, HAG
    Muraca, PJ
    HUMAN PATHOLOGY, 1997, 28 (07) : 827 - 833