The presence of fungi on contact electrical stimulation electrodes and ultrasound transducers in physiotherapy clinics

被引:2
|
作者
Mobin, Mitra [1 ]
Borba, Cintia de Moraes [2 ]
de Moura Filho, Oseas F. [1 ]
de Melo Neto, Antonio Quaresma [1 ]
Valenti, Vitor E. [3 ,4 ]
Marques Vanderlei, Luiz Carlos [4 ]
de Abreu, Luiz Carlos [3 ]
机构
[1] Ciencias Humanas & Tecnol Piaui NOVAFAPI, Fac Saude, Teresina, PI, Brazil
[2] Fiocruz MS, Inst Oswaldo Cruz, Lab Taxon Bioquim & Prospeccao Fungos, BR-21045900 Rio De Janeiro, Brazil
[3] Univ Fed Sao Paulo, Disciplina Cardiol, Dept Med, Sao Paulo, Brazil
[4] Univ Estadual Paulista, Fac Ciencias & Tecnol, Dept Fisioterapia, Presidente Prudente, SP, Brazil
关键词
Fungi; Physical therapy (specialty); Electrodes; Ultrasonics; Infection;
D O I
10.1016/j.physio.2010.11.010
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives To evaluate the presence of fungi on contact electrodes and ultrasound transducers from physiotherapy clinics. Design Quantitative study conducted at the Laboratory of Microbiology and Immunology, Faculty of Health Sciences and Technology of Piaui - NOVAFAPI, Teresina, Brazil. Setting Sample collection was performed in 10 clinics ( 20 ultrasound transducers and 20 contact electrodes). Main outcome measures Swabs were soaked with saline solution, inoculated in culture and incubated for filamentous fungi and yeast growth. Results Fourteen taxons were identified: Acremomium hyalinulum (Sacc.), Aspergillus terreus, Candida albicans, Cladosporium cladosporioides, Cladosporium elatum, Cladosporium oxysporum, Cladosporium sphaerospermum, Cladosphialophora bantiana, Curvularia clavata, Curvularia senegalensis, Fusarium oxysporum, Penicillium decumbens, Scopulariopsis candida and Sporothrix schenckii. Aspergillus terreus, Cladosporium oxysporum, Sporothrix shenckii and Candida albicans were found most often on contact electrodes, and Penicillium decumbens and Cladosporium cladosporioides were found most often on ultrasound transducers. Conclusion Fungi were found on all of the contact electrodes and ultrasound transducers. Physiotherapy professionals need to improve the disinfection procedures for this equipment. (C) 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:273 / 277
页数:5
相关论文
共 3 条
  • [1] Determination of time of death via electrical stimulation of musculature - Muscle stimulation by needle electrodes versus surface contact electrodes
    Krause, D
    Kuchheuser, W
    Schoning, R
    El Aboubi, S
    [J]. KRIMINALISTIK, 1998, 52 (02): : 129 - 131
  • [2] LIQUID METAL ELECTRODES MICRO-ARRAY FOR ELECTRICAL STIMULATION VIA DIRECT CONTACT
    David, R.
    Miki, N.
    [J]. 2018 IEEE MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2018, : 373 - 375
  • [3] The control of neural cell-to-cell interactions through non-contact electrical field stimulation using graphene electrodes
    Heo, Chaejeong
    Yoo, Jeongwan
    Lee, Siyoung
    Jo, Areum
    Jung, Susie
    Yoo, Hyosun
    Lee, Young Hee
    Suh, Minah
    [J]. BIOMATERIALS, 2011, 32 (01) : 19 - 27