Influence of Abutment Design on Stress Distribution in Narrow Implants with Marginal Bone Loss: A Finite Element Analysis

被引:9
|
作者
Yenigun, Serdar [1 ]
Ercal, Pinar [2 ,3 ]
Ozden-Yenigun, Elif [4 ]
Bulent Katiboglu, Ahmet [5 ]
机构
[1] Private Practice, Istanbul, Turkey
[2] Queen Mary Univ London QMUL, Ctr Oral Immunobiol & Regenerat Med, London E1 2AD, England
[3] Queen Mary Univ London QMUL, Barts & London Sch Med & Dent, Inst Dent, Ctr Oral Clin Res, London E1 2AD, England
[4] Royal Coll Art, Sch Design, London, England
[5] Atlas Univ, Dept Oral & Maxillofacial Surg, Fac Dent, Istanbul, Turkey
关键词
dental implants; finite element analysis; marginal bone loss; DENTAL IMPLANT; REMOVAL TORQUE; MORSE-TAPER; SCREW; CONNECTIONS; DIAMETER; LENGTH; RESISTANCE; RESORPTION; INTERFACE;
D O I
10.11607/jomi.8554
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to determine the effect of solid (one-piece) and two-piece abutments on the stress profile of narrow implants with marginal bone loss. Materials and Methods: Solid and two-piece abutments were connected to a conical internal octagon-connection implant (3.3 mm in diameter, 10 mm in length) and restored with a single crown. Three-dimensional finite element analysis was used to simulate the stress distribution in implant models with different levels of marginal bone resorption (0, 1, 2, and 3 mm). The effect of the design variables under increased bone resorption scenarios, including abutment screw length and diameter, was assessed. Static loading was applied to determine the mechanical response of the implant and cortical and trabecular bone. Results: Marginal bone resorption levels dominated the mechanical response under static loading conditions. A marginal bone loss of 3 mm significantly increased stress values in the implant vicinity and abutment screw. Both abutment designs displayed similar stress distribution in the surrounding bone, but lower stress values were observed in the implant body with two-piece abutments. The abutment screw length was more effective in the resultant stress, as the longer screws reduced the stress in the implants. Conclusion: Marginal bone resorption magnitude is the crucial parameter in biomechanics to determine the mechanical behavior. As bone loss increases, resultant stress around implants under mastication forces may lead to implant failure, regardless of abutment type.
引用
收藏
页码:640 / 649
页数:10
相关论文
共 50 条
  • [1] Effect of different design of abutment and implant on stress distribution in 2 implants and peripheral bone: A finite element analysis study
    Kul, Esra
    Korkmaz, Ismail Hakki
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (05): : 664.e1 - 664.e9
  • [2] Biomechanical consequences of progressive marginal bone loss around oral implants: a finite element stress analysis
    Akca, Kivanc
    Cehreli, Murat Cavit
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (07) : 527 - 535
  • [3] Biomechanical consequences of progressive marginal bone loss around oral implants: a finite element stress analysis
    Kivanc Akca
    Murat Cavit Cehreli
    Medical and Biological Engineering and Computing, 2006, 44 : 527 - 535
  • [4] Effects of Marginal Bone Loss Progression on Stress Distribution in Different Implant-Abutment Connections and Abutment Materials: A 3D Finite Element Analysis Study
    Lin, Ching-Ping
    Shyu, Yi-Ting
    Wu, Yu-Ling
    Tsai, Ming-Hsu
    Chen, Hung-Shyong
    Wu, Aaron Yu-Jen
    MATERIALS, 2022, 15 (17)
  • [5] Influence of Abutment Screw Preload on Stress Distribution in Marginal Bone
    Khraisat, Ameen
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (02) : 303 - 307
  • [6] Influence of Implant/Abutment Connection on Stress Distribution to Implant-Surrounding Bone: A Finite Element Analysis
    Hanaoka, Marcia
    Alexandre Gehrke, Sergio
    Mardegan, Fabio
    Gennari, Cesar Roberto
    Taschieri, Silvio
    Del Fabbro, Massimo
    Corbella, Stefano
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (07): : 565 - 571
  • [7] Experimental evaluation of stress distribution with narrow diameter implants: A finite element analysis
    Cinel, Sezgi
    Celik, Ersan
    Sagirkaya, Elcin
    Sahin, Onur
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (03): : 417 - 425
  • [8] Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis
    Tada, S
    Stegaroiu, R
    Kitamura, E
    Miyakawa, O
    Kusakari, H
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (03) : 357 - 368
  • [9] Influence of different implant-abutment connections on stress distribution in single tilted implants and peripheral bone: A three-dimensional finite element analysis
    Ozturk, Ozgur
    Kulunk, Tolga
    Kulunk, Safak
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2018, 29 (04) : 513 - 526
  • [10] Influence of implant abutment type on stress distribution in bone under various loading conditions using finite element analysis
    Chun, HJ
    Shin, HS
    Han, CH
    Lee, SH
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2006, 21 (02) : 195 - 202