Short column GC/MS with increased analysis speed by peak-hopping

被引:0
|
作者
Matz, G [1 ]
Harder, A [1 ]
Walte, A [1 ]
Munchmeyer, W [1 ]
机构
[1] Tech Univ Hamburg Harburg, D-21071 Hamburg, Germany
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Speeding up analytical time is the best to enlarge the profit from GC/MS (gaschromatography/mass spectrometry) analysis. Especially in field applications like emergency response with mobile GC/MS high speed analysis are demanded. GC separation is done with short capillary columns and optimized temperature programs consisting of extremely high heating rates. GC/MS analysis of organic mixtures are performed in less than 2 min. For this purpose a new infrared heated GC has been developed. A maximum heating rate of 1000 degrees C/min in a temperature range up to 300 degrees C is achieved. The sample throughput is raised by factor 5 to 20 compared to fast GC/MS or normal laboratory methods.
引用
收藏
页码:705 / 709
页数:3
相关论文
共 50 条
  • [1] ANALYSIS OF ACIDIC METABOLITES BY CAPILLARY COLUMN GC AND GC/MS
    LIEBICH, HM
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1983, 6 (12): : 640 - 650
  • [2] INCREASED SPEED OF STEROID ANALYSIS BY CAPILLARY GC AND GC-MS - EFFECTS OF SAMPLE PRETREATMENT AND SAMPLE INTRODUCTION
    CURVERS, J
    MARIS, F
    CRAMERS, C
    SCHUTJES, C
    RIJKS, J
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1984, 7 (07): : 414 - 422
  • [3] Rapid measurement of free phytosterols in tobacco by short-column GC/MS/MS
    Ai, J
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1997, 45 (10) : 3932 - 3935
  • [4] ANALYTICAL METHOD OF GUAZATINE BY GC-MS WITH A SHORT CAPILLARY COLUMN
    IMANAKA, M
    KADOTA, M
    OGAWA, N
    KUMASHIRO, K
    MORI, T
    JOURNAL OF PESTICIDE SCIENCE, 1993, 18 (02): : 141 - 146
  • [5] Pressure-tunable dual-column ensembles for high-speed GC and GC/MS
    Sacks, R
    Coutant, C
    Veriotti, T
    Grall, A
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 2000, 23 (03): : 225 - 234
  • [6] Rapid GC-MS analysis of methamphetamine and its metabolites in urine-application of a short narrow-bore capillary column to GC-MS
    Fujii, Hiroshi
    Hara, Kenji
    Kashimura, Seiichi
    Kageura, Mitsuyoshi
    Kashiwagi, Masayuki
    Miyoshi, Aya
    Ikeda, Sachiko
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 842 (02): : 116 - 120
  • [7] Determination of short chain polychlorinated paraffins in fish samples by short column GC/ECNI-MS
    Coelhan, M
    ANALYTICAL CHEMISTRY, 1999, 71 (20) : 4498 - 4505
  • [8] Analysis of short chain chlorinated paraffins in sediment samples from the Czech Republic by short-column GC/ECNI-MS
    Stejnarová, P
    Coelhan, M
    Kostrhounová, R
    Parlar, H
    Holoubek, I
    CHEMOSPHERE, 2005, 58 (03) : 253 - 262
  • [9] High-speed GC and GC/MS with a series-coupled column ensemble using stop-flow operation
    Veriotti, T
    Sacks, R
    ANALYTICAL CHEMISTRY, 2001, 73 (13) : 3045 - 3050
  • [10] OPTIMIZATION OF COLUMN PARAMETERS IN CAPILLARY GC MS FOR ANALYSIS OF ENVIRONMENTAL-POLLUTANTS
    FUKUSHIMA, M
    YAMAMOTO, T
    MASUMOTO, K
    BUNSEKI KAGAKU, 1987, 36 (03) : 154 - 158