Electroanalysis of tetracycline using nickel-implanted boron-doped diamond thin film electrode applied to flow injection system

被引:11
|
作者
Treetepvijit, S
Chuanuwatanakul, S
Einaga, Y
Sato, R
Chailapakul, O [1 ]
机构
[1] Chulalongkorn Univ, Fac Sci, Dept Chem, Bangkok 10330, Thailand
[2] Keio Univ, Fac Sci & Technol, Dept Chem, Yokohama, Kanagawa 2238522, Japan
关键词
D O I
10.2116/analsci.21.531
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical analysis of tetracycline was investigated using nickel-implanted boron-doped diamond thin film electrode by cyclic voltammetry and amperometry with a flow injection system. Cyclic voltammetry was used to study the electrochemical oxidation of tetracycline. Comparison experiments were carried out using as-deposited boron-doped diamond thin film electrode (BDD). Nickel-implanted boron-doped diamond thin film electrode (Ni-DIA) provided well-resolved oxidation irreversible cyclic voltammograms. The current signals were higher than those obtained using the as-deposited BDD electrode. Results using nickel-implanted boron-doped diamond thin film electrode in flow injection system coupled with amperometric detection are presented. The optimum potential for tetracycline was 1.55 V versus Ag/AgCl. The linear range of 1.0 to 100 mu M and the detection limit of 10 nM were obtained. In addition, the application for drug formulation was also investigated.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 50 条
  • [1] Electroanalysis of Tetracycline Using Nickel-implanted Boron-doped Diamond Thin Film Electrode Applied to Flow Injection System
    Surudee Treetepvijit
    Suchada Chuanuwatanakul
    Yasuaki Einaga
    Rika Sato
    Orawon Chailapakul
    Analytical Sciences, 2005, 21 : 531 - 535
  • [2] Electroanalysis of lincomycin using boron-doped diamond thin film electrode applied to flow injection system
    Boonsong, K
    Chuanuwatanakul, S
    Wangfuengkanagul, N
    Chailapakul, O
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) : 627 - 632
  • [3] Electrochemical analysis of acetaminophen using a boron-doped diamond thin film electrode applied to flow injection system
    Wangfuengkanagul, N
    Chailapakul, O
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (05) : 841 - 847
  • [4] Electrochemical determination of captopril at boron-doped diamond thin film electrode applied to a flow injection system
    Siangproh, W
    Ngamukot, P
    Chailapakul, O
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 91 (1-3) : 60 - 66
  • [5] Electrochemical analysis of D-penicillamine using a boron-doped diamond thin film electrode applied to flow injection system
    Wangfuengkanagul, N
    Chailapakul, O
    TALANTA, 2002, 58 (06) : 1213 - 1219
  • [6] Electrochemical glucose detection using nickel-implanted boron-doped diamond electrodes
    Ohnishi, K
    Einaga, Y
    Notsu, H
    Terashima, C
    Rao, TN
    Park, SG
    Fujishima, A
    ELECTROCHEMICAL AND SOLID STATE LETTERS, 2002, 5 (03) : D1 - D3
  • [7] Use of nickel implanted boron-doped diamond thin film electrode coupled to HPLC system for the determination of tetracyclines
    Treetepvijit, S
    Preechaworapun, A
    Praphairaksit, N
    Chuanuwatanakul, U
    Einaga, Y
    Chailapakul, O
    TALANTA, 2006, 68 (04) : 1329 - 1335
  • [8] Electrochemical analysis of chloramphenicol using boron-doped diamond electrode applied to a flow-injection system
    Chuanuwatanakul, Suchada
    Chailapakul, Orawon
    Motomizu, Shoji
    ANALYTICAL SCIENCES, 2008, 24 (04) : 493 - 498
  • [9] Electrochemical Analysis of Chloramphenicol Using Boron-doped Diamond Electrode Applied to a Flow-Injection System
    Suchada Chuanuwatanakul
    Orawon Chailapakul
    Shoji Motomizu
    Analytical Sciences, 2008, 24 : 493 - 498
  • [10] A flow injection method for the analysis of tetracycline antibiotics in pharmaceutical formulations using electrochemical detection at anodized boron-doped diamond thin film electrode
    Wangfuengkanagul, N
    Siangproh, W
    Chailapakul, O
    TALANTA, 2004, 64 (05) : 1183 - 1188