MRI Guided Myocardial Perfusion PET Image Reconstruction

被引:0
|
作者
Tang, Jing [1 ]
Wang, Xinhui [1 ]
Karakatsanis, Nicolas A. [2 ]
Lu, Lijun [3 ]
Rahmim, Arman [2 ]
机构
[1] Oakland Univ, Dept Elect & Comp Engn, Rochester, MI 48309 USA
[2] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21287 USA
[3] Southern Med Univ, Sch Biomed Engn, Guangzhou, Guangdong, Peoples R China
基金
美国国家科学基金会;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Integrated whole-body PET/MRI provides opportunities to fully take advantage of simultaneously acquired anatomical and functional information. The purpose of this study is to incorporate the MR measured anatomical information in myocardial perfusion (MP) PET image reconstruction and to quantitatively evaluate the reconstructed images. Using the 4D XCAT phantom, we simulated cardiac-gated MP PET data with and without a perfusion defect and the corresponding MR images. Noisy PET sinograms were generated with count levels comparable to patient Rb-82 MP PET measurement. MR images were simulated using the SIMRI simulator, with the MR sequence specified to be 3D T1-weighted as used in a clinical PET/MRI protocol. For each cardiac gate, we applied the closed-form maximum a posteriori (MAP) PET image reconstruction taking the joint-entropy (JE) between intensity of the PET and MR images as the prior. To quantitatively evaluate the reconstructed images, we used the tradeoff between bias and noise on the left ventricle polar map. The contrast recovery ratio was also calculated to quantify the ability to classify the polar maps with and without the MP defect. On the whole polar map and its segments, the activity values estimated from the JE MAP algorithm showed significantly improved noise versus bias tradeoff compared to those from the conventional maximum likelihood algorithm. The JE MAP algorithm also resulted in improved noise versus contrast recovery for the MP defect. To conclude, we demonstrated quantitatively improved performance of the anato-functional JE MAP reconstruction on MP PET imaging with realistic simulation. The reconstruction technique will have promising potential applications especially in the emerging integrated cardiac PET/MR imaging.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] MRI-Guided Motion-Corrected PET Image Reconstruction for Cardiac PET/MRI
    Munoz, Camila
    Ellis, Sam
    Nekolla, Stephan G.
    Kunze, Karl P.
    Vitadello, Teresa
    Neji, Radhouene
    Botnar, Rene M.
    Schnabel, Julia A.
    Reader, Andrew J.
    Prieto, Claudia
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2021, 62 (12) : 1768 - 1774
  • [2] MRI GUIDED DEEP LEARNING IMAGE RECONSTRUCTION FOR LOW DOSE PET
    Pain, C.
    Sudarshan, V. P.
    Upadhyay, U.
    Awate, S. P.
    Egan, G. F.
    [J]. INTERNAL MEDICINE JOURNAL, 2021, 51 : 29 - 30
  • [3] Image registration in myocardial perfusion MRI
    Wong, K. K.
    Wu, E. X.
    Ng, M. C.
    Wu, Y.
    Tse, H. F.
    Lau, C. P.
    Yang, E. S.
    [J]. 2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 453 - 454
  • [4] Multitracer Guided PET Image Reconstruction
    Ellis, Sam
    Mallia, Andrew
    McGinnity, Colm J.
    Cook, Gary J. R.
    Reader, Andrew J.
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (05) : 499 - 509
  • [5] Motion compensated reconstruction for myocardial perfusion MRI
    Sajan Goud Lingala
    Edward DiBella
    Christophe Chefd'hotel
    Mariappan Nadar
    Mathews Jacob
    [J]. Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [6] Direct Bayesian parametric image reconstruction from dynamic myocardial perfusion PET data
    Li, Yang
    He, Yuru
    Rahmim, Arman
    Lu, Lijun
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [7] Evaluation of an MRI-Guided PET Image Reconstruction Approach With Adaptive Penalization Strength
    Cabello, Jorge
    Jurkiewicz, Michael T.
    Andrade, Andrea
    Benzinger, Tammie L. S.
    An, Hongyu
    Anazodo, Udunna C.
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2024, 8 (03) : 277 - 286
  • [8] Measuring myocardial perfusion: the role of PET, MRI and CT
    Qayyum, A. A.
    Kastrup, J.
    [J]. CLINICAL RADIOLOGY, 2015, 70 (06) : 576 - 584
  • [9] Evaluation of perfusion and image quality changes by reconstruction methods in 13N-ammonia myocardial perfusion PET/CT
    Do, Yong Ho
    Lee, Hong Jae
    Kim, Jin Eui
    Im, Hyung Jun
    Lee, Jae Sung
    Lee, Dong Soo
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [10] Evaluation of perfusion and image quality changes by reconstruction methods in 13N-ammonia myocardial perfusion PET/CT
    Do, Yong Ho
    Lee, Hong Jae
    Kim, Jin Eui
    Im, Hyung Jun
    Lee, Jae Sung
    Lee, Dong Soo
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55