Influence of build angulation on the mechanical properties of a direct-metal laser-sintered cobalt-chromium used for removable partial denture frameworks

被引:13
|
作者
Aarts, John M. [1 ]
Choi, Joanne Jung Eun [1 ]
Metcalfe, Steven [2 ]
Bennani, Vincent [1 ]
机构
[1] Univ Otago, Fac Dent, Sir John Walsh Res Inst, POB 56, Dunedin 9054, New Zealand
[2] Addit Manufacture Solut Ltd, Res & Dev Div, Lower Hutt, New Zealand
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2021年 / 126卷 / 02期
关键词
CO-CR; FATIGUE; ALLOY;
D O I
10.1016/j.prosdent.2020.06.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Direct-metal laser-sintering (DMLS) technologies are being used to manufacture removable partial denture frameworks; however, the build parameters are not well documented. Purpose. The purpose of this in vitro study was to investigate the impact of 3 different build angulations on a dental cobalt-chromium (Sint-Tech ST2724G) alloy by comparing the tensile properties and nanoindentation hardness. The null hypothesis was that no change would be found in the tensile properties of the different build angulation groups. Material and methods. Dumbbell-shaped tensile specimens were produced by using stereolithographic models in accordance with American Society for Testing and Materials testing standard E8/E8M-16ae1. Specimens (n=10) were fabricated by using DMLS additive manufacturing with 3 different angulations (0, 45, and 90 degrees). Tensile testing was carried out to assess yield strength (0.2% permanent offset), elongation (%) at failure, and ultimate tensile strength (GPa). Scanning electron microscope (SEM) images were used to analyze the fracture surfaces. One 10x10x10 mm cube specimen at each orientation was prepared, and nanoindentation was used to determine hardness and elastic modulus. One-way ANOVA was used to evaluate the overall effects with interaction between groups and post hoc testing applied where the interaction was statistically significant (alpha=.05). Results. The 45-degree build angulation resulted in the lowest mean elastic modulus of 213.3 GPa and the highest tensile strength of 1180.9 MPa. The 90-degree build angulation resulted in the highest mean elongation of 10.6% and the highest elastic modulus of 234.0 MPa. Within comparison of the different angulations indicated that various groups had statistically significant differences (P<.05). The SEM analysis indicated different fracture topography among the different build angles. Conclusions. The cobalt-chromium dental alloy manufactured by DMLS produced favorable mechanical properties. The SEM analysis combined with the tensile test results suggest that the direction of the build angle in relation to the laser melt pattern does impact the mechanical properties of the alloy.
引用
收藏
页码:224 / 230
页数:7
相关论文
共 22 条
  • [1] Effect of Palatal Vault Depth on the Trueness of Metal Laser-Sintered and Cast Cobalt-Chromium Removable Partial Denture Frameworks
    Abd El Hamed, Hala
    Hebeshi, Ahmed M.
    Husseiny, Eman
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (04): : 353 - 360
  • [2] Fatigue behavior of removable partial denture cast and laser-sintered cobalt-chromium (CoCr) and polyetheretherketone (PEEK) clasp materials
    Zheng, Jenny
    Aarts, John M.
    Ma, Sunyoung
    Waddell, John N.
    Choi, Joanne J. E.
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2022, 8 (06): : 1496 - 1504
  • [3] Laser welding of a cobalt-chromium removable partial denture alloy
    NaBadalung, DP
    Nicholls, JI
    JOURNAL OF PROSTHETIC DENTISTRY, 1998, 79 (03): : 285 - 290
  • [4] Fit and Retention of Cobalt-Chromium Removable Partial Denture Frameworks Fabricated with Selective Laser Melting
    Rues, Stefan
    Tasaka, Akinori
    Fleckenstein, Isabella
    Yamashita, Shuichiro
    Rammelsberg, Peter
    Boehm, Sophia
    Schwindling, Franz Sebastian
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (08)
  • [5] Effect of internal design changes on the mechanical properties of laser-sintered cobalt-chromium specimens
    Ekren, Orhun
    Kocak, Elif Figen
    Ucar, Yurdanur
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (03): : 508 - 512
  • [6] Microstructure, mechanical properties, and retentive forces of cobalt-chromium removable partial denture frameworks fabricated by selective laser melting followed by heat treatment
    Lee, Wei-Fang
    Wang, Jia-Chang
    Hsu, Ching-Ying
    Peng, Pei-Wen
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (01): : 115 - 121
  • [7] Physicomechanical properties of cobalt-chromium removable partial denture palatal major connectors fabricated by selective laser melting
    Salim, Safa
    Salleh, Nosizana Mohd
    Abidin, Zubaidah Zanul
    Yunus, Norsiah
    Rahmat, Rabiah
    Ibrahim, Norliza
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 530.e1 - 530.e7
  • [8] Influence of Local Porosity on the Mechanical Properties of Direct Metal Laser-Sintered 1.2709 Alloy
    Hatos, Istvan
    Fekete, Imre
    Harangoz, Dora
    Hargitai, Hajnalka
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2020, 66 (06): : 351 - 357
  • [9] Fracture strength of porcelain fused to metal crowns made of cast, milled or laser-sintered cobalt-chromium
    Suleiman, Sozan Hama
    von Steyern, Per Vult
    ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (05) : 1280 - 1289
  • [10] Effect of Ozone on Corrosion Behavior of a Cobalt-Chromium Alloy Used in Removable Partial Denture Framework: An In Vitro Study
    Rangrazi, Abdolrasoul
    Mirmortazavi, Amirtaher
    Imani, Reyhaneh
    Nodehi, Davood
    JOURNAL OF ADVANCED ORAL RESEARCH, 2021, 12 (02) : 304 - 309