Equivalent input disturbance-based load frequency control for smart grid with air conditioning loads

被引:11
|
作者
Jin, Li [1 ,2 ,3 ,4 ]
He, Yong [1 ,2 ,4 ]
Zhang, Chuan-Ke [1 ,2 ,4 ]
Shangguan, Xing-Chen [1 ,2 ,3 ,4 ]
Jiang, Lin [3 ]
Wu, Min [1 ,2 ,4 ]
机构
[1] China Univ Geosci, Sch Automat, Wuhan 430074, Peoples R China
[2] Hubei Key Lab Adv Control & Intelligent Automat C, Wuhan 430074, Peoples R China
[3] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
[4] Minist Educ, Engn Res Ctr Intelligent Technol Geoexplorat, Wuhan 430074, Peoples R China
关键词
equivalent input disturbance; load frequency control; parameter uncertainties; wind power; air conditioning loads; DYNAMIC DEMAND RESPONSE; REPETITIVE CONTROL; REJECTION; DELAY; SYSTEM; LFC; INTEGRATION; STRATEGY; MODEL;
D O I
10.1007/s11432-020-3120-0
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Integrating intermittent wind power into power systems results in low or zero inertia, threatening their frequency stability. To accommodate intermittent generations, the demand response (DR) is introduced, and air conditioning loads (ACs) account for an increasing proportion of all loads. The replacement of traditional generators with wind turbines and the ACs user uncertainties produce parameter uncertainties. This paper aims to construct an equivalent input disturbance (EID)-based load frequency control (LFC) strategy for the power system by considering wind power and ACs. First, an open-loop model is constructed for the LFC scheme with parameter uncertainties. Then, the parameter uncertainties and external disturbance are lumped into a fictitious disturbance, which is estimated using an EID estimator. By incorporating the estimation of disturbance into the control input, the disturbance-rejection performance is achieved. Next, the Lyapunov theory is used to derive the two linear-matrix-inequality-based asymptotic stability criteria. A design algorithm is developed for the EID-based LFC scheme by exploiting an overall performance evaluation index. Finally, simulation results for the single-area and two-area LFC schemes show that, compared with the existing approaches, the method presented realizes the better disturbance rejection and higher robustness against parameter uncertainties, wind power fluctuation, and tie-line power changes. Additionally, its robustness to time delays is verified.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Equivalent input disturbance-based load frequency control for smart grid with air conditioning loads
    Li Jin
    Yong He
    Chuan-Ke Zhang
    Xing-Chen Shangguan
    Lin Jiang
    Min Wu
    [J]. Science China Information Sciences, 2022, 65
  • [2] Equivalent input disturbance-based load frequency control for smart grid with air conditioning loads
    Li JIN
    Yong HE
    Chuan-Ke ZHANG
    Xing-Chen SHANGGUAN
    Lin JIANG
    Min WU
    [J]. Science China(Information Sciences), 2022, 65 (02) : 106 - 123
  • [3] Equivalent Input Disturbance-Based Control: Analysis, Development, and Applications
    Yin, Xiang
    Shi, Yuntao
    She, Jinhua
    Wang, Hanping
    [J]. IEEE TRANSACTIONS ON CYBERNETICS, 2024, 54 (04) : 2654 - 2667
  • [4] Equivalent Input Disturbance-based Model Predictive Control of Shaking Table System
    Lei, Qi
    Wang, Cheng
    [J]. 2023 IEEE 6TH INTERNATIONAL CONFERENCE ON INDUSTRIAL CYBER-PHYSICAL SYSTEMS, ICPS, 2023,
  • [5] Resilient robust model predictive load frequency control for smart grids with air conditioning loads
    Jike, Shiluo
    Liu, Guobao
    Li, Feng
    Zhang, Changyu
    Wang, Qi
    Zhou, Mengxia
    Qian, Haiya
    [J]. IET RENEWABLE POWER GENERATION, 2024, : 2326 - 2339
  • [6] A Novel Equivalent Input Disturbance-Based Adaptive Sliding Mode Control for Singularly Perturbed Systems
    Liu, Xiaomin
    Yang, Chunyu
    Che, Zhiyuan
    Zhou, Linna
    [J]. IEEE ACCESS, 2021, 9 : 12463 - 12472
  • [7] Grid Planning: Agent Based Approach for Early Notification of Air Conditioning Loads to Smart Grid
    Ayyubi, Saqib Rehan
    Ustun, Taha Selim
    Miao, Yuan
    [J]. PROCEEDINGS OF THE 2015 10TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, 2015, : 1766 - 1771
  • [8] Provision of Supplementary Load Frequency Control via Aggregation of Air Conditioning Loads
    Zhou, Lei
    Li, Yang
    Wang, Beibei
    Wang, Zhe
    Hu, Xiaoqing
    [J]. ENERGIES, 2015, 8 (12): : 14098 - 14117
  • [9] Equivalent input disturbance-based robust LFC strategy for power system with wind farms
    Liu, Fang
    Ma, Junjie
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (20) : 4582 - 4588
  • [10] Equivalent Input Disturbance-Based Control Design for Three Phase Dual-Stage Grid-Tied Photovoltaic System Considering Dead Time Effect
    Liu, Fang
    Fan, Zhen
    Liu, Qianyi
    Zou, Runmin
    [J]. FRONTIERS IN ENERGY RESEARCH, 2021, 9