Analytical method development for the determination of emerging contaminants in water using supercritical-fluid chromatography coupled with diode-array detection

被引:17
|
作者
del Carmen Salvatierra-Stamp, Vilma [1 ]
Ceballos-Magana, Silvia G. [2 ]
Gonzalez, Jorge [1 ]
Ibarra-Galvan, Valentin [1 ]
Muniz-Valencia, Roberto [1 ]
机构
[1] Univ Colima, Fac Ciencias Quim, Coquimatlan 28400, Colima, Mexico
[2] Univ Colima, Fac Ciencias, Colima 28045, Mexico
关键词
Emerging contaminants; Supercritical-fluid chromatography; Solid-phase extraction; Environmental water samples; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; TANDEM MASS-SPECTROMETRY; WASTE-WATER; SAMPLES;
D O I
10.1007/s00216-015-8581-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An analytical method using supercritical-fluid chromatography coupled with diode-array detection for the determination of seven emerging contaminants-two pharmaceuticals (carbamazepine and glyburide), three endocrine disruptors (17 alpha-ethinyl estradiol, bisphenol A, and 17 beta-estradiol), one bactericide (triclosan), and one pesticide (diuron)-was developed and validated. These contaminants were chosen because of their frequency of use and their toxic effects on both humans and the environment. The optimized chromatographic separation on a Viridis BEH 2-EP column achieved baseline resolution for all compounds in less than 10 min. This separation was applied to environmental water samples after sample preparation. The optimized sample treatment involved a preconcentration step by means of solid-phase extraction using C18-OH cartridges. The proposed method was validated, finding recoveries higher than 94 % and limits of detection and limits of quantification in the range of 0.10-1.59 mu g L-1 and 0.31-4.83 mu g L-1, respectively. Method validation established the proposed method to be selective, linear, accurate, and precise. Finally, the method was successfully applied to environmental water samples.
引用
收藏
页码:4219 / 4226
页数:8
相关论文
共 50 条
  • [1] Analytical method development for the determination of emerging contaminants in water using supercritical-fluid chromatography coupled with diode-array detection
    Vilma del Carmen Salvatierra-Stamp
    Silvia G. Ceballos-Magaña
    Jorge Gonzalez
    Valentin Ibarra-Galván
    Roberto Muñiz-Valencia
    Analytical and Bioanalytical Chemistry, 2015, 407 : 4219 - 4226
  • [2] Determination of phenolic compounds in water samples by on-line solid-phase extraction—supercritical-fluid chromatography with diode-array detection
    J. L. Bernal
    M. J. Nozal
    L. Toribio
    M. L. Serna
    F. Borrull
    R. M. Marcé
    E. Pocurull
    Chromatographia, 1997, 46 : 295 - 300
  • [3] Determination of phenolic compounds in water samples by on-line solid-phase extraction - Supercritical-fluid chromatography with diode-array detection
    Bernal, JL
    Nozal, MJ
    Toribio, L
    Serna, ML
    Borrull, F
    Marce, RM
    Pocurull, E
    CHROMATOGRAPHIA, 1997, 46 (5-6) : 295 - 300
  • [4] On-line solid-phase extraction coupled to supercritical fluid chromatography with diode array detection for the determination of pesticides in water
    Bernal, JL
    Jimenez, JJ
    Rivera, JM
    Toribio, L
    delNozal, MJ
    JOURNAL OF CHROMATOGRAPHY A, 1996, 754 (1-2) : 145 - 157
  • [5] Determination of tiagabine in serum by liquid chromatography with diode-array detection
    Wnuk, W
    THERAPEUTIC DRUG MONITORING, 2003, 25 (04) : 530 - 530
  • [6] INFRARED DETECTION IN SUPERCRITICAL-FLUID CHROMATOGRAPHY USING XENON
    HEALY, MA
    JENKINS, TJ
    POLIAKOFF, M
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1991, 10 (03) : 92 - 97
  • [7] Quantification of Retinoid Compounds by Supercritical Fluid Chromatography Coupled to Ultraviolet Diode Array Detection
    M. Méjean
    M. Vollmer
    A. Brunelle
    D. Touboul
    Chromatographia, 2013, 76 : 1097 - 1105
  • [8] Quantification of Retinoid Compounds by Supercritical Fluid Chromatography Coupled to Ultraviolet Diode Array Detection
    Mejean, M.
    Vollmer, M.
    Brunelle, A.
    Touboul, D.
    CHROMATOGRAPHIA, 2013, 76 (17-18) : 1097 - 1105
  • [9] Analytical quality parameters of high performance liquid chromatography with diode-array detection method for multiresidue determination of pesticides.
    Baez, ME
    Zincker, J
    BOLETIN DE LA SOCIEDAD CHILENA DE QUIMICA, 1999, 44 (03): : 357 - 366
  • [10] Online supercritical fluid extraction - supercritical fluid chromatography - diode-array detection: an interesting approach for investigation of milk thistle (Silybum marianum) preparations
    Gibitz-Eisath, N.
    Sturm, S.
    Jochems, P.
    Ludwig, R.
    Stuppner, H.
    PLANTA MEDICA, 2019, 85 (18) : 1438 - 1438