Prediction of the natural frequencies of different degrees of degenerated human lumbar segments L2-L3 using dynamic finite element analysis

被引:6
|
作者
Fan, Ruoxun [1 ]
Liu, Jie [1 ]
Liu, Jun [2 ]
机构
[1] Jilin Inst Chem Technol, Dept Automot Engn, Jilin 132022, Jilin, Peoples R China
[2] Jilin Univ, Second Hosp Jilin Univ, Changchun 130025, Peoples R China
基金
中国国家自然科学基金;
关键词
Lumbar spinal segment; Degeneration; Vibration; Resonance; Natural frequency; Dynamic finite element analysis; INTERVERTEBRAL DISC; ANNULUS FIBROSUS; MOTION SEGMENT; VIBRATION; SPINE; BEHAVIORS; MODEL;
D O I
10.1016/j.cmpb.2021.106352
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and Objective: Chronic exposure to resonant environment may cause more serious injuries to human lumbar spine than other vibrations. On the condition that the natural frequency of human lumbar spine is known, excitation frequency from an external vibration source can be optimized to keep away from the natural frequency and thus avoid lumbar resonance. Therefore, this study aimed to present an approach to predict the natural frequency of the human lumbar spine. Methods: Four poroelastic finite element models of human L2-L3 spinal motion segments with different degrees of degeneration were established. Dynamic finite element analyses of these models during 1 h of vibration were then conducted. The mechanical parameters of these models under vibrations at different excitation frequencies were predicted. The excitation frequencies that resulted in the greatest changes in the lumbar mechanical parameters were identified as the natural frequencies of the established L2-L3 spinal motion segments. Results: Simulation results showed that the natural frequencies of the healthy and mildly degenerated L2-L3 spinal motion segments, moderately degenerated L2-L3 spinal motion segments, and seriously degenerated L2-L3 spinal motion segments were in the range of 5-7, 3-5, and 1-3 Hz, respectively. Conclusions: The predicted results indicated that the natural frequencies of the human L2-L3 spinal motion segments gradually decreased with the severity of degeneration. These phenomena may be related to changes in the lumbar structures and materials because of degeneration. This study provided a feasible method to predict the lumbar natural frequencies for different populations, which may be helpful in optimizing external vibration sources to avoid lumbar resonance. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 34 条
  • [1] Finite element investigation on the dynamic mechanical properties of low-frequency vibrations on human L2-L3 spinal motion segments with different degrees of degeneration
    Fan, Ruoxun
    Liu, Jie
    Liu, Jun
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2020, 58 (12) : 3003 - 3016
  • [2] Finite element investigation on the dynamic mechanical properties of low-frequency vibrations on human L2–L3 spinal motion segments with different degrees of degeneration
    Ruoxun Fan
    Jie Liu
    Jun Liu
    Medical & Biological Engineering & Computing, 2020, 58 : 3003 - 3016
  • [3] Establishing finite element contact model of human L1~L5 lumbar segments
    Su, Jin
    Zhao, Wen-Zhi
    Chen, Bing-Zhi
    Li, Bin
    He, Sheng-Wei
    Fang, Xu
    Yiyong Shengwu Lixue/Journal of Medical Biomechanics, 2010, 25 (03): : 200 - 205
  • [4] Presentation of an Approach on Determination of the Natural Frequency of Human Lumbar Spine Using Dynamic Finite Element Analysis
    Fan Ruoxun
    Liu Jie
    Liu Jun
    Wang Weijun
    APPLIED BIONICS AND BIOMECHANICS, 2019, 2019
  • [5] Comparative Analysis of Microendoscopic and Open Laminectomy for Single-Level Lumbar Spinal Stenosis at L1-L2 or L2-L3
    Yamato, Yukimasa
    Nagata, Kosei
    Kawamura, Naohiro
    Higashikawa, Akiro
    Takeshita, Yujiro
    Tozawa, Keiichiro
    Fukushima, Masayoshi
    Urayama, Daiki
    Ono, Takashi
    Hara, Nobuhiro
    Okamoto, Naoki
    Azuma, Seiichi
    Iwai, Hiroki
    Sugita, Shurei
    Yoshida, Yuichi
    Hirai, Shima
    Masuda, Kazuhiro
    Jim, Yu
    Ohtomo, Nozomu
    Nakamoto, Hideki
    Kato, So
    Taniguchi, Yuki
    Tanaka, Sakae
    Oshima, Yasushi
    WORLD NEUROSURGERY, 2024, 183 : E408 - E414
  • [6] Effect of body weight on the L3 lumbar vertebra with lumbar spinal stenosis in different body-bending degrees: A finite element simulation
    Chuchard, Pearanat
    Prathumwan, Din
    Chaiya, Inthira
    Trachoo, Kamonchat
    RESULTS IN APPLIED MATHEMATICS, 2022, 14
  • [7] Biomechanical Study of Lumbar Spine (L2-L4) Using Hybrid Stabilization Device - A Finite Element Analysis
    Jain, Pushpdant
    Khan, Mohammed Rajik
    INTERNATIONAL JOURNAL OF MANUFACTURING MATERIALS AND MECHANICAL ENGINEERING, 2020, 10 (01) : 20 - 32
  • [8] Material sensitivity study on lumbar motion segment (L2-L3) under sagittal plane loadings using probabilistic method
    Lee, KK
    Teo, EC
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2005, 18 (02): : 163 - 170
  • [9] Biomechanical Effects of the Implant Designed for Posterior Dynamic Stabilization of the Lumbar Spine (L4-L5): A Finite Element Analysis Study
    Taherzadeh, Paniz
    Kelleci, Kubra
    Ozer, Sevil
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2024, 31 (01): : 193 - 199
  • [10] FINITE-ELEMENT EVALUATION OF CONTACT LOADS ON FACETS OF AN L2 L3 LUMBAR SEGMENT IN COMPLEX LOADS
    SHIRAZIADL, A