Occupational exposure during nitric oxide inhalational therapy in a pediatric intensive care setting

被引:0
|
作者
Markhorst, DG
Leenhoven, T
Uiterwijk, JW
Meulenbelt, J
vanVught, AJ
机构
[1] WILHELMINA CHILDRENS HOSP,DEPT PEDIAT,PEDIAT INTENS CARE UNIT,NL-3501 CA UTRECHT,NETHERLANDS
[2] FREE UNIV AMSTERDAM HOSP,DEPT PEDIAT,PEDIAT INTENS CARE UNIT,NL-1007 MB AMSTERDAM,NETHERLANDS
[3] NATL INST PUBL HLTH & ENVIRONM,AIR RES LAB,NL-3720 BA BILTHOVEN,NETHERLANDS
[4] NATL INST PUBL HLTH & ENVIRONM,NATL POISONS CONTROL CTR,NL-3720 BA BILTHOVEN,NETHERLANDS
关键词
nitric oxide; occupational exposure; high-frequency oscillatory ventilation; chemiluminescence assay; mechanical ventilation;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To determine the amount of occupational exposure to nitric oxide (NO) and nitrogen dioxide (NO2) during NO inhalational therapy. Design: In a standard pediatric intensive care room, 800 ppm NO was delivered to a high-Frequency oscillator and mixed with 100% O-2 to obtain 20 ppm NO in the inspiratory gas flow. NO and NO2 concentrations in room air were measured using a chemiluminescence analyzer. Air samples were taken from a height of 150 cm at a horizontal distance of 65 cm from the ventilator in a nonventilated and in a well-ventilated room with and without an expiratory gas exhaust under normal intensive care environmental conditions. Setting: Pediatric intensive care unit in a university children's hospital. Mesaurement and results: Maximal concentrations of NO and NO2 were reached after 4 h NO use. Without exhaust, in a nonventilated room, environmental NO and NO2 concentration rose to a maximum of 0.462 and 0.064 ppm, respectively. With the use of an expiratory gas exhaust, NO and NO2 concentrations were 0.176 and 0.042 ppm, respectively. With normal air-conditioning, these values were 0.075 and 0.034 ppm, respectively, without the use of an expiratory gas exhaust. With expiratory gas exhaust added to normal air-conditioning, values for NO and NO2 were 0.035 and 0.030 ppm, respectively. Conclusions: The use of 20 ppm NO, even under minimal room ventilation conditions, did not lead to room air levels of NO or NO2 that should be considered toxic to adjacent intensive care patients or staff, Slight increases in NO and NO2 concentrations were measurable but remained within occupational safety limits, The use of an exhaust system and normal room ventilation lowers NO and NO2 concentrations Further to almost background levels.
引用
收藏
页码:954 / 958
页数:5
相关论文
共 50 条
  • [1] Inhalational methanol exposure in an occupational setting
    Reichert, C.
    Stuerer, A.
    Rauber-Luethy, C.
    Bertke, P.
    Kupferschmidt, H.
    CLINICAL TOXICOLOGY, 2008, 46 (05) : 418 - 419
  • [2] Occupational exposure to the inhalational anesthetic agents nitrous oxide and deflurane during pediatric strabism surgery
    Byhahn, C
    Wilke, HJ
    Strouhal, U
    Westphal, K
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1999, 215 (06) : 367 - 369
  • [3] Physical and occupational therapy utilization in a pediatric intensive care unit
    Cui, Liang R.
    LaPorte, Megan
    Civitello, Matthew
    Stanger, Meg
    Orringer, Maxine
    Casey, Frank, III
    Kuch, Bradley A.
    Beers, Sue R.
    Valenta, Cynthia A.
    Kochanek, Patrick M.
    Houtrow, Amy J.
    Fink, Ericka L.
    JOURNAL OF CRITICAL CARE, 2017, 40 : 15 - 20
  • [4] Electroencephalogram changes during inhalation with nitric oxide in the pediatric intensive care patient - A preliminary report
    Moenkhoff, M
    Schmitt, B
    Wohlrab, G
    Waldvogel, K
    Fanconi, S
    Baenziger, O
    CRITICAL CARE MEDICINE, 1998, 26 (11) : 1887 - 1892
  • [5] Use of inhaled nitric oxide in pediatric cardiac intensive care unit
    Ozturk, Erkut
    Haydin, Sertac
    Tanidir, Ibrahim Cansaran
    Ozyilmaz, Isa
    Ergul, Yakup
    Erek, Ersin
    Guzeltas, Alper
    Odemis, Ender
    Bakir, Ihsan
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2016, 44 (03): : 196 - 202
  • [6] CHARACTERIZATION OF INHALED NITRIC OXIDE UTILIZATION IN A PEDIATRIC INTENSIVE CARE UNIT
    Palumbo, Kathryn
    Biagas, Katherine
    Berman-Rosensweig, Erika
    CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [7] Occupational Therapy in Intensive Care
    Yucel, Hulya
    TURKISH JOURNAL OF INTENSIVE CARE-TURK YOGUN BAKIM DERGISI, 2023, 21 (02): : 59 - 67
  • [8] Inhalational sedation during transport to the intensive care unit
    M Bellgardt
    C Sirtl
    M Bergmann
    D Weyhe
    A Terporten
    H Laubenthal
    A Meiser
    Critical Care, 11 (Suppl 2):
  • [9] Early presumptive antifungal therapy in a pediatric intensive care (PICU) setting
    Cimino, M
    Papo, M
    Tristram, D
    Rosenkranz, E
    Kielma, D
    Joshi, P
    PEDIATRIC RESEARCH, 1999, 45 (04) : 38A - 38A
  • [10] Early Presumptive Antifungal Therapy in a Pediatric Intensive Care (PICU) Setting
    Michael Cimino
    Michele Papo
    Debra Tristram
    Eliot Rosenkranz
    Donna Kielma
    Prashant Joshi
    Pediatric Research, 1999, 45 : 38 - 38