Spontaneous blinks as a criterion of visual fatigue during prolonged work on visual display terminals

被引:36
|
作者
Kaneko, K [1 ]
Sakamoto, K [1 ]
机构
[1] Univ Electrocommun, Dept Commun & Syst, Ergon Lab, Chofu, Tokyo 1828585, Japan
关键词
D O I
10.2466/PMS.92.1.234-250
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
Visual fatigue caused by prolonged work viewing a Visual Display Terminals (VDT) and of work reading a hard-copy were assessed by electromyogram (EMG) waveform and electroculogram (EOG) waveform in spontaneous blinks as objective criteria, and by questionnaire of subjective feeling, and by task performance. The duration and the amplitude of the EMG of the orbicularis ocular muscle on the right side and the EOG of the vertical direction to the eyelid were measured for 10 subjects who participated in a figure task consisting of the addition of single-digit numbers on a VDT work or a work with a hard-copy. The mean values of the duration and the amplitude of the EMG and the EOG a ere evaluated by the averaging of 10 waveforms of the spontaneous blinks for all subjects. The time lag from the EMG to the EOG in the process of the generation of spontaneous blinks was also analyzed. These five parameters were evaluated during the work rime. The mean values for the duration of the EMG increased gradually during the work time, but the amplitude did not show significant difference between the prework and a work time. There was no significant change of the duration of the EOG, hut the mean amplitude of the EOG decreased as the work time progressed, and the time lag significantly extended. The blinks frequency increased relatively when using a VDT. The rate of fluctuation for these parameters was higher during use of a VDT than use of a hard-copy. The time lag at five hours of VDT work was extended by 90% based on the value at the pre-work . The symptoms of general fatigue and fatigue of the eyes increased linearly durinA the VDT a ork for six hours. The results indicated a significant correlation between the objective parameters for the activity of the spontaneous blinks, i.e., duration and amplitude of EMG and EGG. and the time lag between EMG and EGG, and the subjective feeling was recognized in the time course of the task. These experimental results suggested that the parameters regarding the EMG and the EOG for the spontaneous blinks were effective indices for assessing visual fatigue during prolonged VDT work.
引用
收藏
页码:234 / 250
页数:17
相关论文
共 50 条
  • [1] Fatigue evaluation for work load of Visual Display Terminals (VDT) operation
    Hachiya, Yuriko
    Ogai, Harutoshi
    Okazaki, Hiroko
    Fujisaki, Takeshi
    Uchida, Kazuhiko
    Oda, Susumu
    Wada, Futoshi
    Mori, Koji
    2007 INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS, VOLS 1-6, 2007, : 729 - +
  • [4] Meta-analysis of visual fatigue based on visual display terminals
    Wang, Gaofeng
    Cui, Yanru
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [5] SKIN SYMPTOMS AND DISEASE DURING WORK WITH VISUAL-DISPLAY TERMINALS
    BERGQVIST, U
    WAHLBERG, JE
    CONTACT DERMATITIS, 1994, 30 (04) : 197 - 204
  • [6] ACCOMMODATION AND VISUAL FATIGUE IN DISPLAY WORK
    OSTBERG, O
    DISPLAYS, 1980, 2 (02) : 81 - 85
  • [7] EYE DISCOMFORT AND WORK WITH VISUAL-DISPLAY TERMINALS
    BERGQVIST, UO
    KNAVE, BG
    SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1994, 20 (01) : 27 - 33
  • [8] IS THE SKIN AFFECTED BY WORK AT VISUAL-DISPLAY TERMINALS
    WAHLBERG, JE
    LIDEN, C
    DERMATOLOGIC CLINICS, 1988, 6 (01) : 81 - 85
  • [9] Visual work modes in operators of video display terminals
    Shapovalov, S.L.
    Milyavskaya, T.I.
    Bursov, I.V.
    Aleksandrov, A.S.
    Arutyunova, O.V.
    Meditsina Truda I Promyshlennaya Ekologiya, 2002, (06): : 22 - 25
  • [10] SPONTANEOUS-ABORTION AND VISUAL-DISPLAY TERMINALS (VDTS)
    LLAURADO, JG
    INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1989, 24 (02): : 73 - 78