Frequency Scanning Interferometry Absolute Distance Measurement Method Based on Optical Spectrum Calibration

被引:0
|
作者
Shang Yue [1 ]
Wu Tengfei [1 ]
Lin Jiarui [1 ]
Yang Linghui [1 ]
Zhou Qiang [1 ]
Zhu Jigui [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measurement Technol & Instru, Tianjin 300072, Peoples R China
关键词
measurements; frequency scanning interferometry; absolute distance measurement; absorption spectrum; dispersion effect; WAVELENGTH SHIFT; LASER-DIODE; PRECISION; ACCURACY;
D O I
10.3788/AOS202242.1212001
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
With high precision and sensitivity, frequency scanning interferometry (FSI) absolute distance measurement technique is getting more and more attention in the field of large-scale equipment manufacturing. Building an optical fiber auxiliary interferometer in an FSI system to realize the precise monitoring of optical frequency changes is necessary for achieving higher ranging accuracy. However, the stability of optical path of the auxiliary interferometer is limited by the environmental factors and dispersion effect, which would reduce the accuracy seriously. An optical spectrum calibration based FSI absolute distance measurement method is proposed in this paper for this problem. The optical path of the auxiliary interferometer in the FSI system is calibrated in situ with the help of the absorption spectrum of hydrogen cyanide (HCN) to provide stable and accurate optical frequency reference. What's more, a fast compensation method for dispersion mismatch error is proposed to eliminate the influence of dispersion mismatch effect caused by the fiber optic assisted interferometer on measurement results. The proposed method is verified by comparison experiments with commercial interferometer at a range of 20 m. The result shows that the largest ranging deviation of the system is less than 50 mu m, and the repeatability is better than +4 mu m.
引用
收藏
页数:11
相关论文
共 27 条
  • [1] ATLAS Collaboration, 2008, JINST, V3
  • [2] FSI Ranging Error Compensation Method Based on Laser Self-Mixng Vibration Measurement
    Chai Xiaobo
    Wu Tengfei
    Yin Pufu
    [J]. LASER & OPTOELECTRONICS PROGRESS, 2021, 58 (11)
  • [3] Application of Femtosecond Optical Frequency Comb in Precise Absolute Distance Measurement
    Cui Pengfei
    Yang Linghui
    Lin Jiarui
    Zhu Jigui
    [J]. LASER & OPTOELECTRONICS PROGRESS, 2018, 55 (12)
  • [4] Multi-channel absolute distance measurement system with sub ppm-accuracy and 20 m range using frequency scanning interferometry and gas absorption cells
    Dale, John
    Hughes, Ben
    Lancaster, Andrew J.
    Lewis, Andrew J.
    Reichold, Armin J. H.
    Warden, Matthew S.
    [J]. OPTICS EXPRESS, 2014, 22 (20): : 24869 - 24893
  • [5] Frequency-scanning interferometry for depth mapping using the Fabry-Perot cavity as a reference with compensation for nonlinear optical frequency scanning
    Deng, Zhongwen
    Liu, Zhigang
    Gu, Shaowei
    Jia, Xingyu
    Deng, Wen
    Yan, Haihong
    [J]. OPTICS COMMUNICATIONS, 2020, 455
  • [6] Nonlinear calibration of frequency modulated continuous wave LIDAR based on a microresonator soliton comb
    Jia, Linhua
    Wang, Yang
    Wang, Xinyu
    Zhang, Fumin
    Wang, Weiqiang
    Wang, Jindong
    Zheng, Jihui
    Chen, Jiawei
    Song, Mingyu
    Ma, Xin
    Yuan, Meiyan
    Little, Brent
    Chu, Sai Tek
    Cheng, Dong
    Qu, Xinghua
    Zhao, Wei
    Zhang, Wenfu
    [J]. OPTICS LETTERS, 2021, 46 (05) : 1025 - 1028
  • [7] DISTANCE MEASUREMENT BY THE WAVELENGTH SHIFT OF LASER DIODE LIGHT
    KIKUTA, H
    IWATA, K
    NAGATA, R
    [J]. APPLIED OPTICS, 1986, 25 (17): : 2976 - 2980
  • [8] ABSOLUTE DISTANCE MEASUREMENT BY WAVELENGTH SHIFT INTERFEROMETRY WITH A LASER DIODE - SOME SYSTEMATIC-ERROR SOURCES
    KIKUTA, H
    IWATA, K
    NAGATA, R
    [J]. APPLIED OPTICS, 1987, 26 (09): : 1654 - 1660
  • [9] Antibody responses to SARS-CoV-2 in patients with COVID-19
    Long, Quan-Xin
    Liu, Bai-Zhong
    Deng, Hai-Jun
    Wu, Gui-Cheng
    Deng, Kun
    Chen, Yao-Kai
    Liao, Pu
    Qiu, Jing-Fu
    Lin, Yong
    Cai, Xue-Fei
    Wang, De-Qiang
    Hu, Yuan
    Ren, Ji-Hua
    Tang, Ni
    Xu, Yin-Yin
    Yu, Li-Hua
    Mo, Zhan
    Gong, Fang
    Zhang, Xiao-Li
    Tian, Wen-Guang
    Hu, Li
    Zhang, Xian-Xiang
    Xiang, Jiang-Lin
    Du, Hong-Xin
    Liu, Hua-Wen
    Lang, Chun-Hui
    Luo, Xiao-He
    Wu, Shao-Bo
    Cui, Xiao-Ping
    Zhou, Zheng
    Zhu, Man-Man
    Wang, Jing
    Xue, Cheng-Jun
    Li, Xiao-Feng
    Wang, Li
    Li, Zhi-Jie
    Wang, Kun
    Niu, Chang-Chun
    Yang, Qing-Jun
    Tang, Xiao-Jun
    Zhang, Yong
    Liu, Xia-Mao
    Li, Jin-Jing
    Zhang, De-Chun
    Zhang, Fan
    Liu, Ping
    Yuan, Jun
    Li, Qin
    Hu, Jie-Li
    Chen, Juan
    [J]. NATURE MEDICINE, 2020, 26 (06) : 845 - +
  • [10] Method based on chirp decomposition for dispersion mismatch compensation in precision absolute distance measurement using swept-wavelength interferometry
    Lu, Cheng
    Liu, Guodong
    Liu, Bingguo
    Chen, Fengdong
    Hu, Tao
    Zhuang, Zhitao
    Xu, Xinke
    Gan, Yu
    [J]. OPTICS EXPRESS, 2015, 23 (25): : 31662 - 31671