Antigen excess and non-linearity of serum free light chain measurements

被引:0
|
作者
Vercammen, Martine [1 ]
Bossuyt, Xavier [2 ]
机构
[1] UZ Brussel, Haematol Lab, B-1090 Brussels, Belgium
[2] Univ Ziekenhuis Leuven, Lab Med, Louvain, Belgium
关键词
D O I
10.1016/j.cca.2012.02.001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
引用
收藏
页码:952 / 952
页数:1
相关论文
共 50 条
  • [1] Risk of antigen excess in serum free light chain measurements
    Daval, Sandrine
    Tridon, Arlette
    Mazeron, Nicole
    Ristori, Jean-Michel
    Evrard, Bertrand
    CLINICAL CHEMISTRY, 2007, 53 (11) : 1985 - 1986
  • [2] Detecting Antigen Excess in Serum Free Light Chain Measurement
    Zaydman, Mark
    Logsdon, Nicole
    Scheller, Katherine
    Gronowski, Ann
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2018, 149 : S175 - S175
  • [3] Non-Linearity Of The Binding Site Free Light Chain Assay In A Selected Population
    Booth, R. A.
    Ooi, D. S.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A122 - A122
  • [4] Serum free light chain immunoassays: A guide to antigen excess detection
    Jenner, Ellen
    Levoguer, Alison
    Evans, Josie
    Harding, Stephen
    CLINICA CHIMICA ACTA, 2012, 413 (9-10) : 949 - 949
  • [5] Incidence of antigen excess in serum free light chain assays.
    Clark, R. J.
    Lockington, K. S.
    Tostrud, L. J.
    Katzmann, J. A.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A148 - A148
  • [6] Overestimation of free light chain antigen excess rate
    Vercammen, Martine J.
    Broodtaerts, Linda
    Meirlaen, Patricia
    Bossuyt, Xavier
    CLINICA CHIMICA ACTA, 2015, 444 : 297 - 302
  • [7] Anisotropy and non-linearity of absorption of intensive IR light by free electrons in germanium
    Vasetskii, V. M.
    Ignatenko, V. A.
    Poroshin, V. N.
    SEMICONDUCTOR PHYSICS QUANTUM ELECTRONICS & OPTOELECTRONICS, 2005, 8 (03) : 12 - 15
  • [8] Detection of serum free light chains: the problem with antigen excess
    Bosmann, Markus
    Koessler, Juergen
    Stolz, Herbert
    Walter, Ulrich
    Knop, Stefan
    Steigerwald, Udo
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (10) : 1419 - 1422
  • [9] Automated alarm to detect antigen excess in serum free immunoglobulin light chain kappa and lambda assays
    Urdal, Petter
    Amundsen, Erik K.
    Toska, Karin
    Klingenberg, Olav
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2014, 74 (07): : 575 - 581
  • [10] A compact detector system for simultaneous measurements of the light yield non-linearity and timing properties of scintillators
    Sabot, Benoit
    Dutsov, Chavdar
    Cassette, Philippe
    Mitev, Krasimir
    Hamel, Matthieu
    Bertrand, Guillaume H. V.
    Lebbou, Kheirreddine
    Dujardin, Christophe
    SCIENTIFIC REPORTS, 2024, 14 (01)