Ring-reinforced prosthesis for paracolostomy hernia

被引:18
|
作者
de Ruiter, P
Bijnen, AB
机构
[1] Med Ctr Alkmaar, Dept Surg, NL-1815 JD Alkmaar, Netherlands
[2] Free Univ Amsterdam, Med Ctr, Inst Med Educ, Amsterdam, Netherlands
关键词
parastomal hernia; polypropylene ring; polypropylene mesh prosthesis; rectus abdominis muscle;
D O I
10.1159/000087147
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: The reported recurrence rate after paracolostomy hernia repair, with or without mesh, varies between 47 and 100%. We developed a polypropylene mesh prosthesis with a central opening, reinforced with a polypropylene ring, that can be implanted suprafascially through a mucocutaneous incision. Methods: The results of a consecutive series of 46 patients with paracolostomy hernia, who were implanted with this prosthesis between October 1988 and November 2000 in 12 hospitals, were analyzed. The mean follow-up was 5 (range 1-13) years. Results: The early infection rate was 4.3%. Two patients were lost to follow-up. The late infection rate was 2.3%. Seven patients (15.9%) developed a recurrent parastomal hernia and were all reoperated. The prosthesis was definitively removed in 10 patients. Conclusion: Although implantation of this new prosthesis is not without complications, it offers the lowest reported recurrence rate until now. Copyright (c) 2005 S. Karger AG, Basel.
引用
收藏
页码:152 / 156
页数:5