Anterior chamber air-fluid exchange for graft adhesion during Descemet stripping automated endothelial keratoplasty surgery
被引:3
|
作者:
Bialer, Omer
论文数: 0引用数: 0
h-index: 0
机构:
Rabin Med Ctr, Dept Ophthalmol, IL-49100 Petah Tiqwa, Israel
Tel Aviv Univ, Sackler Fac Med, IL-69978 Tel Aviv, IsraelRabin Med Ctr, Dept Ophthalmol, IL-49100 Petah Tiqwa, Israel
Bialer, Omer
[1
,2
]
Bahar, Irit
论文数: 0引用数: 0
h-index: 0
机构:
Rabin Med Ctr, Dept Ophthalmol, IL-49100 Petah Tiqwa, Israel
Tel Aviv Univ, Sackler Fac Med, IL-69978 Tel Aviv, IsraelRabin Med Ctr, Dept Ophthalmol, IL-49100 Petah Tiqwa, Israel
Bahar, Irit
[1
,2
]
机构:
[1] Rabin Med Ctr, Dept Ophthalmol, IL-49100 Petah Tiqwa, Israel
[2] Tel Aviv Univ, Sackler Fac Med, IL-69978 Tel Aviv, Israel
One of the most important steps during Descemet stripping automated endothelial keratoplasty (DSAEK) is attaching the donor Descemet lenticule to the host's cornea. This is usually carried out by injecting air into the anterior chamber with a syringe and needle. We present an alternative technique using an air fluid exchange system connected to an anterior chamber maintainer used in 22 cases in our institute. This technique has proven to be simple and fast, thus facilitating the successful performance of DSAEK surgery.