共 50 条
Spectrophotometric and reversed-phase high-performance liquid chromatographic methods for simultaneous determination of escitalopram oxalate and clonazepam in combined tablet dosage form
被引:0
|作者:
Gandhi, Santosh Vilashchand
[1
]
Dhavale, Nilesh Dnyandev
[1
]
Jadhav, Vijay Yeshawantrao
[1
]
Sabnis, Shweta Sadanand
[1
]
机构:
[1] AISSMS, Coll Pharm, Dept Pharmaceut Anal, Pune, Maharashtra, India
关键词:
D O I:
暂无
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
Simple, accurate, precise, and sensitive ultraviolet spectrophotometric and reversed-phase high-performance liquid chromatographic (RP-HPLC) methods for simultaneous estimation of escitalopram oxalate (ESC) and clonazepam (CLO) in combined tablet dosage form have been developed and validated. The spectroscopic method employs an absorbance correction method using 238.6 and 308 nm as 2 wavelengths for estimation with methanol and water as solvents. Beer's law is obeyed in the concentration range of 10.0-50.0 and 0.5-3.0 mu g/ml for ESC and CLO, respectively. The RP-HPLC method uses a Jasco HPLC system with HiQ SiL C18 column (250 x 4.6 mm id) acetonitrile-0.005 M tetrabutylammonium hydrogen sulfate (55 + 45, v/v) as the mobile phase, and satranidazole as an internal standard. The detection was carried out using an ultraviolet detector set at 287 nm. For the HPLC method, Beer's law is obeyed in the concentration range of 10.0-60.0 and 0.5-3.0 mu g/mL for ESC and CLO, respectively. Both methods have been successfully applied for the analysis of the drugs in a pharmaceutical formulation. Results of analysis were validated statistically and by recovery studies.
引用
收藏
页码:33 / 38
页数:6
相关论文