A study on the address delay time with various ramp waveforms in AC plasma display panel

被引:0
|
作者
Li, Zhao Hui [1 ]
Hong, Seong Jae [1 ]
Im, Seung Hyeok [1 ]
Kwon, Sang Jik [1 ]
机构
[1] Kyungwon Univ, Dept Elect Engn, Seong Nam City 461701, Kyunggi Do, South Korea
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It is important to reduce addressing delay time for AC plasma display panel (PDP). In this paper, address delay time was investigated with van. ous slopes of the ramp pulse during a reset ramp-up and ramp-down period. The results showed that the address delay time wildly varied with different slopes of the ramp-up and ramp-down waveforms. The relationship between priming particles and various ramp waveforms was also analyzed.
引用
收藏
页码:839 / 842
页数:4
相关论文
共 50 条
  • [1] Study of address discharge delay time in shadow mask plasma display panel
    Yang L.
    Tu Y.
    Li Q.
    Zhu Z.
    Wang B.
    Zhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology, 2010, 30 (02): : 122 - 127
  • [2] Improvement of Address Discharge Delay Time Using Modified Reset Waveform in AC Plasma Display Panel
    Shin, Bhum Jae
    Dal Park, Hyung
    Tae, Heung-Sik
    IEICE TRANSACTIONS ON ELECTRONICS, 2012, E95C (05) : 958 - 963
  • [3] Effect of modified scan and sustain waveforms on black luminance and address voltage in an AC plasma display panel
    Jana, Raj Kumar
    Dutt, Santanu Kumar
    2008 SID INTERNATIONAL SYMPOSIUM, DIGEST OF TECHNICAL PAPERS, VOL XXXIX, BOOKS I-III, 2008, 39 : 1737 - 1741
  • [4] Study of various coplanar gaps discharges in ac plasma display panel
    Choi, KC
    Shin, NH
    Lee, KS
    Shin, BJ
    Lee, SE
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2006, 34 (02) : 385 - 389
  • [5] Effects of pre-reset conditions on reset discharge from ramp reset waveforms in AC plasma display panel
    Shin, BJ
    Choi, KC
    Seo, JH
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2005, 52 (01) : 17 - 22
  • [6] Bipolar scan waveform for fast address in AC plasma display panel
    Cho, KD
    Tae, HS
    Chien, SI
    IEICE TRANSACTIONS ON ELECTRONICS, 2004, E87C (01) : 116 - 119
  • [7] Bipolar scan waveform for fast address in AC plasma display panel
    Cho, Ki-Duck
    Tae, Heung-Sik
    Chien, Sung-Il
    IEICE Transactions on Communications, 2004, E87-B (01) : 116 - 119
  • [8] A modified ramp waveform to reduce reset period in AC plasma display panel
    Park, CH
    Lee, SH
    Kim, DH
    Ryu, JH
    Lee, HJ
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2002, 49 (05) : 782 - 786
  • [9] Effects of Address-on-Time on Wall Voltage Variation during Address-Period in AC Plasma Display Panel
    Choi, Byung-Tae
    Park, Hyung Dal
    Tae, Heung-Sik
    IEICE TRANSACTIONS ON ELECTRONICS, 2009, E92C (11) : 1347 - 1352
  • [10] Numerical Analysis and Experiment on Discharge Characteristics Under Various Address Electrode Widths in AC Plasma Display Panel
    Park, Choon-Sang
    Kim, Jae Young
    Jung, Eun Young
    Tae, Heung-Sik
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2012, 564 : 56 - 66