Voltage positive feedback based active method for islanding detection of photovoltaic system with string inverter using sliding mode controller

被引:27
|
作者
Bakhshi, Reza [1 ]
Sadeh, Javad [1 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Elect Engn, Fac Engn, Mashhad, Iran
关键词
Islanding detection; Voltage positive feedback; String inverter; Sliding mode controller; Reference signal; POWER POINT TRACKING; DISTRIBUTED GENERATORS; PERFORMANCE; RELAYS; SCHEME;
D O I
10.1016/j.solener.2016.08.051
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Islanding is an undesirable condition that is potentially dangerous to the maintenance or repair staff and may cause damages to sensitive equipments. Therefore, islanding detection is a mandatory feature for distributed generators (DGs), including grid-connected photovoltaic systems (GCPVSs). This article presents a new active islanding detection method for GCPVSs with string inverter based on sliding mode controller. In the proposed method, a feedback of point of common coupling (PCC) voltage has been inserted to the reference signal of sliding mode controller as a new maximum power point tracking (MPPT) technique. Through applying this voltage positive feedback (VPF), the inverter output power and consequently, the PCC voltage decreases in islanding condition. This procedure is repeated until the PCC voltage falls below the under voltage (UV) relay setting. The conventional VPF technique attempts to increase and decrease the output power in elevated and declined PCC voltage cases after grid disconnection, respectively. However, due to the input power limitation and MPPT in GCPVSs in the PCC voltage raised cases, the output active power cannot be elevated any further. In this study, the active power perturbation has been only applied in deceleration mode, considering the disturbance definition in the inverter voltage control loop. Therefore, unlike the conventional VPF scheme, it has the advantage of not violating the "conservation of energy law". The performance of the proposed method is evaluated by simulating a GCPVS with string inverter supplying a local load, connected to the grid. Simulation results show troubleshooting the conventional VPF scheme drawbacks as well as successful operation of the proposed method in islanding and non-islanding conditions even in multi-inverter systems. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:564 / 577
页数:14
相关论文
共 50 条
  • [1] A New Method of Islanding Detection Based on Voltage Positive Feedback
    Cheng, Ying
    Zhao, Long
    Luo, Yaqiao
    Hu, Cungang
    Rui, Tao
    Qi, Xing
    PROCEEDINGS OF THE 2016 IEEE 11TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2016, : 2261 - 2264
  • [2] Novel Active Frequency Drift with Positive Feedback Method of Photovoltaic Islanding Detection
    Wang Ruiqi
    Wang Weiyu
    Zhao Peng
    Wang Zhaoxin
    Li Sun
    Jin Zhanxin
    Mao Qingbo
    SIXTH INTERNATIONAL CONFERENCE ON ELECTRONICS AND INFORMATION ENGINEERING, 2015, 9794
  • [3] A Novel Islanding Detection Method Based on Positive Feedback Between Active Current and Voltage Unbalance Factor
    Sun, Bo
    Mei, Jun
    Zheng, Jianyong
    2014 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2014, : 31 - 34
  • [4] A novel islanding detection method based on positive feedback of voltage harmonic distortion
    Ma, Jing
    Mi, Chao
    Wang, Zengping
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2012, 36 (01): : 47 - 50
  • [5] Active Frequency Drift Islanding Detection Method with the Positive Feedback by Absolute Value of Voltage Frequency
    Li, Zicheng
    Liu, Xingyu
    Wang, Houneng
    Liu, Xinzhi
    Wang, Xiaomin
    2018 CHINESE AUTOMATION CONGRESS (CAC), 2018, : 578 - 582
  • [6] Interference of various active islanding detection methods with positive feedback in multi-inverter power system
    Chen, Kai
    Wang, Ying
    Tian, Shulin
    Cheng, Yuhua
    Yin, Chun
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2015, 7 (03)
  • [7] Active islanding detection method for inverter-based distribution generation power system
    Chiang, Wen-Jung
    Jou, Hurng-Liahng
    Wu, Jinn-Chang
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) : 158 - 166
  • [8] Consideration on Voltage Fluctuation caused by Active Method of Islanding Detection of Photovoltaic Generation
    Takeshita, Kenta
    Sakamoto, Orie
    Maruyama, Masato
    Harimoto, Tsuyoshi
    2018 7TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2018, : 606 - 611
  • [9] Sliding Mode Control of a Photovoltaic Based Shunt Active Power Filter in Islanding Operation
    Constant, Fanjip Rene
    Hubert, Kom Charles
    Raoul, Dzonde Naoussi Serge
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2022, 12 (04): : 1712 - 1726
  • [10] Islanding detection method for photovoltaic distributed generation based on voltage drifting
    Kamyab, Ebadollah
    Sadeh, Javad
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2013, 7 (06) : 584 - 592