The Effect of Ozonated Water and Chlorhexidine Gluconate on Prevention of Ventilator-Associated Pneumonia: A Double-Blind, Randomized, Clinical Trial

被引:4
|
作者
Hanifi, Nasrin [1 ]
Masoumi, Masomeh [2 ]
Jamshidi, Mohammad Reza [3 ]
Faghihzadeh, Soghrat [4 ]
机构
[1] ZUMS, Zanjan Nursing & Midwifery Sch, Sharak Karmandan St,POB 45154-13191, Zanjan, Iran
[2] Zanjan Univ Med Sci, Sch Nursing & Midwifery, Nursing, Zanjan, Iran
[3] Zanjan Univ Med Sci, Sch Med, Zanjan, Iran
[4] Zanjan Univ Med Sci, Sch Med, Biostat, Zanjan, Iran
关键词
Oral Hygiene; Chlorhexidine Gluconate; Ozone; Ventilator-associated Pneumonia; Mechanical Ventilation; ORAL CARE; MECHANICAL VENTILATION; OZONE; HYGIENE; MOUTHWASH; INFECTION;
D O I
10.5812/ircmj.60576
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The relationship between the oral care and ventilator-associated pneumonia (VAP) was confirmed in patients undergoing ventilation. Objectives: The current study aimed at investigating the effects of chlorhexidine gluconate (CHX) and ozonated water on the prevention of VAP. Methods: The current double-blind, randomized, clinical trial with the experimental and control groups was conducted in Iran in 2014. In the current study, 75 inpatients undergoing ventilation were grouped through the convenience sampling method and randomly allocated into 2 groups based on the inclusion criteria. In the experimental group (39 patients), oral care provided by ozonated water, while in the control group (35 patients), oral care was provided via CHX. Clinical pulmonary infection score (CPIS) was used to examine the rate of VAP infection. Results: According to the results of the current study, the occurrence rate of VAP in the experimental and control groups were 2.4% and 8.3%, respectively that was equal until the 3rd day (P value = 0.339). However, on the 4th day, the VAP occurrence rate in the experimental group (14.6%) was significantly lower than that of the control group (30.6%) (P value = 0.02). Conclusions: Basedonthe results, ozonated water was more effective to prevent VAP than CHX. Ozone water can be used as a suitable alternative mouthwash in patients undergoing mechanical ventilation.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] A randomized double-blind trial of iseganan in prevention of ventilator-associated pneumonia
    Kollef, M
    Pittet, D
    García, MS
    Chastre, J
    Fagon, JY
    Bonten, M
    Hyzy, R
    Fleming, TR
    Fuchs, H
    Bellm, L
    Mercat, A
    Mañez, R
    Martínez, A
    Eggimann, P
    Daguerre, M
    Luyt, CE
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2006, 173 (01) : 91 - 97
  • [2] Reduce the risk of ventilator-associated pneumonia in ICU patients by Ozonated water mouthwash: A double-blind randomized clinical trial
    Izadi, Morteza
    Bagheri, Mahdi
    Far, Ali Bahrami
    Bagheri-baghdasht, Mohammad Sadegh
    Ghasemzadeh, Golshan
    Sureda, Antoni
    Soodmand, Mostafa
    AMERICAN JOURNAL OF INFECTION CONTROL, 2023, 51 (07) : 779 - 785
  • [3] Probiotic prophylaxis to prevent ventilator-associated pneumonia in children on mechanical ventilation: A randomized double-blind clinical trial
    Roshanzamiri, Soheil
    Alemzadeh, Maryam
    Ahmadizadeh, Seyyedeh Narjes
    Behzad, Azita
    Hashemi, Seyyedeh Masumeh
    Salamzadeh, Jamshid
    Mirrahimi, Bahador
    FRONTIERS IN PEDIATRICS, 2022, 10
  • [4] The impact of inspiratory pressure level on prevention of ventilator- associated pneumonia: A double-blind, randomized clinical trial
    Naghibi, Taraneh
    Karimi, Hamideh
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2023, 365 (02): : 162 - 168
  • [5] Effect of multimodality chest physiotherapy in prevention of ventilator-associated pneumonia: A randomized clinical trial
    Pattanshetty, Renu B.
    Gaude, G. S.
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2010, 14 (02) : 70 - 76
  • [6] Prevention of ventilator-associated pneumonia by oral decontamination - A prospective, randomized, double-blind, placebo-controlled study
    Bergmans, DCJJ
    Bonten, MJM
    Gaillard, CA
    Paling, JC
    van der Geest, S
    van Tiel, FH
    Beysens, AJ
    de Leeuw, PW
    Stobberingh, EE
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (03) : 382 - 388
  • [7] OROPHARYNGEAL DECONTAMINATION DECREASES INCIDENCE OF VENTILATOR-ASSOCIATED PNEUMONIA - A RANDOMIZED, PLACEBO-CONTROLLED, DOUBLE-BLIND CLINICAL-TRIAL
    PUGIN, J
    AUCKENTHALER, R
    LEW, DP
    SUTER, PM
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1991, 265 (20): : 2704 - 2710
  • [8] Oral care with 0.12% chlorhexidine for the prevention of ventilator-associated pneumonia in critically ill children: Randomised, controlled and double blind trial
    Kusahara, Denise Miyuki
    Sorgini Peterlini, Maria Angelica
    Goncalves Pedreira, Mavilde Luz
    INTERNATIONAL JOURNAL OF NURSING STUDIES, 2012, 49 (11) : 1354 - 1363
  • [9] Prevention of Ventilator-Associated Pneumonia by Use of Oral Chlorhexidine
    Silvestri, Luciano
    van Saene, Hendrick K. F.
    Milanese, Marco
    Zei, Eraldo
    Blazic, Miranda
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2009, 30 (01):
  • [10] Oral mucosal decontamination with chlorhexidine for the prevention of ventilator-associated pneumonia in children-A randomized, controlled trial
    Sebastian, Meghna Raju
    Lodha, Rakesh
    Kapil, Arti
    Kabra, Sushil K.
    PEDIATRIC CRITICAL CARE MEDICINE, 2012, 13 (05) : E305 - E310