Evaluating the Performance of Low-Cost Air Quality Monitors in Dallas, Texas

被引:16
|
作者
Khreis, Haneen [1 ,2 ]
Johnson, Jeremy [1 ]
Jack, Katherine [3 ]
Dadashova, Bahar [1 ]
Park, Eun Sug [1 ]
机构
[1] Texas A&M Univ Syst, Texas A&M Transportat Inst TTI, Bryan, TX 77807 USA
[2] Texas A&M Univ Syst, Ctr Adv Res Transportat Emiss Energy & Hlth CARTE, Bryan, TX 77807 USA
[3] Nature Conservancy, Texas Chapter, San Antonio, TX 78215 USA
关键词
low-cost sensors; air pollution; criteria air pollutants; co-location; meteorological factors; air quality index; PARTICULATE MATTER; FIELD CALIBRATION; AVAILABLE SENSORS; POLLUTION; VARIABILITY; CLUSTER; PART;
D O I
10.3390/ijerph19031647
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The emergence of low-cost air quality sensors may improve our ability to capture variations in urban air pollution and provide actionable information for public health. Despite the increasing popularity of low-cost sensors, there remain some gaps in the understanding of their performance under real-world conditions, as well as compared to regulatory monitors with high accuracy, but also high cost and maintenance requirements. In this paper, we report on the performance and the linear calibration of readings from 12 commercial low-cost sensors co-located at a regulatory air quality monitoring site in Dallas, Texas, for 18 continuous measurement months. Commercial AQY1 sensors were used, and their reported readings of O-3, NO2, PM2.5, and PM10 were assessed against a regulatory monitor. We assessed how well the raw and calibrated AQY1 readings matched the regulatory monitor and whether meteorology impacted performance. We found that each sensor's response was different. Overall, the sensors performed best for O-3 (R-2 = 0.36-0.97) and worst for NO2 (0.00-0.58), showing a potential impact of meteorological factors, with an effect of temperature on O-3 and relative humidity on PM. Calibration seemed to improve the accuracy, but not in all cases or for all performance metrics (e.g., precision versus bias), and it was limited to a linear calibration in this study. Our data showed that it is critical for users to regularly calibrate low-cost sensors and monitor data once they are installed, as sensors may not be operating properly, which may result in the loss of large amounts of data. We also recommend that co-location should be as exact as possible, minimizing the distance between sensors and regulatory monitors, and that the sampling orientation is similar. There were important deviations between the AQY1 and regulatory monitors' readings, which in small part depended on meteorology, hindering the ability of the low-costs sensors to present air quality accurately. However, categorizing air pollution levels, using for example the Air Quality Index framework, rather than reporting absolute readings, may be a more suitable approach. In addition, more sophisticated calibration methods, including accounting for individual sensor performance, may further improve performance. This work adds to the literature by assessing the performance of low-cost sensors over one of the longest durations reported to date.
引用
收藏
页数:28
相关论文
共 50 条
  • [1] Performance of low-cost monitors to assess household air pollution
    Curto, A.
    Donaire-Gonzalez, D.
    Barrera-Gomez, J.
    Marshall, J. D.
    Nieuwenhuijsen, M. J.
    Wellenius, G. A.
    Tonne, C.
    [J]. ENVIRONMENTAL RESEARCH, 2018, 163 : 53 - 63
  • [2] How standardizing 'low-cost' air quality monitors will help measure pollution
    Brown, Richard J. C.
    Martin, Nicholas A.
    [J]. NATURE REVIEWS PHYSICS, 2023, 5 (03) : 139 - 140
  • [3] Using Low-Cost PM Monitors to Detect Local Changes of Air Quality
    Rogulski, Mariusz
    [J]. POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2018, 27 (04): : 1699 - 1705
  • [4] How standardizing ‘low-cost’ air quality monitors will help measure pollution
    Richard J. C. Brown
    Nicholas A. Martin
    [J]. Nature Reviews Physics, 2023, 5 : 139 - 140
  • [5] Low-cost PM monitors as an opportunity to increase the spatiotemporal resolution of measurements of air quality
    Rogulski, Mariusz
    [J]. INTERNATIONAL SCIENTIFIC CONFERENCE - ENVIRONMENTAL AND CLIMATE TECHNOLOGIES (CONECT 2017), 2017, 128 : 437 - 444
  • [6] Performance evaluation of low-cost air quality sensors: A review
    Kang, Ye
    Aye, Lu
    Ngo, Tuan Duc
    Zhou, Jin
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 818
  • [7] Review of the Performance of Low-Cost Sensors for Air Quality Monitoring
    Karagulian, Federico
    Barbiere, Maurizio
    Kotsev, Alexander
    Spinelle, Laurent
    Gerboles, Michel
    Lagler, Friedrich
    Redon, Nathalie
    Crunaire, Sabine
    Borowiak, Annette
    [J]. ATMOSPHERE, 2019, 10 (09)
  • [8] Performance assessment of low-cost environmental monitors and single sensors under variable indoor air quality and thermal conditions
    Demanega, Ingrid
    Mujan, Igor
    Singer, Brett C.
    Andelkovic, Aleksandar S.
    Babich, Francesco
    Licina, Dusan
    [J]. BUILDING AND ENVIRONMENT, 2021, 187
  • [9] Development of an environmental chamber for evaluating the performance of low-cost air quality sensors under controlled conditions
    Papapostolou, Vasileios
    Zhang, Hang
    Feenstra, Brandon J.
    Polidori, Andrea
    [J]. ATMOSPHERIC ENVIRONMENT, 2017, 171 : 82 - 90
  • [10] An open-source tool for evaluating calibration techniques used in low-cost air pollutant monitors
    Tatsch, Daniel Trevisan
    Garcia Ramirez, Alejandro Rafael
    Campo, Fernando
    Hoinaski, Leonardo
    Gonzalez-Dalmau, Evelio
    [J]. ELECTRONICS LETTERS, 2023, 59 (10)