Flow visualization and heat transfer performance of annular thermosyphon heat pipe

被引:29
|
作者
Kim, In Guk [1 ]
Kim, Kyung Mo [1 ]
Jeong, Yeong Shin [1 ]
Bang, In Cheol [1 ]
机构
[1] UNIST, Dept Nucl Engn, 50 UNIST Gil, Ulsan 44919, South Korea
基金
新加坡国家研究基金会;
关键词
Heat pipe; Thermosyphon; Visualization; Operation limit; Heat transfer; THERMAL PERFORMANCE; 2-PHASE THERMOSIPHON; COOLING SYSTEM; LOOP; PREDICTION; NANOFLUID; ARRAY;
D O I
10.1016/j.applthermaleng.2017.07.116
中图分类号
O414.1 [热力学];
学科分类号
摘要
To clearly understand the operation phenomena Of thermosyphon heat pipes, current study experimentally investigated the visualization of the operation and limit conditions for a water-filled thermosyphon as well as its thermal performance. The flow patterns and behaviors at the evaporator region are essential for understanding the heat transfer mechanism of heat pipes. Flow visualization was conducted during operation and limiting condition using a high-speed camera. In this study, the flow regime and heat transfer were observed during changes in the flow path, wick and fill ratio. In the thermosyphon, bubbly flow at low heat loads, slug and churn flow at high heat loads, and churn-annular flow at limiting condition were visualized. In the annular thermosyphon, generated bubbles rapidly coalesced; therefore, slug flow occurred at low heat flux, without bubbly flow. The Gr numbers of the thermosyphon and annular thermosyphon were 2.1 x 10(6)-1.99 x 10(7) and 3.5 x 10(4)-1.5 x 10(6), respectively. Therefore, the shear viscosity force was more dominant than buoyancy force in the annular thermosyphon. At the operation limit, a thin liquid film following dry-out was observed at peak surface temperature. When the cross-sectional area of the evaporator was reduced by 40.3%, the operational limit of the capillary heat pipe decreased by 10.2-26.3%, while that of thermosyphon heat pipe decreased by 22.1-44.2%. Experimental results were utilized to describe these effects on the performance of the thermosyphon heat pipes according to changes of cross-sectional area of the flow path, fill ratios, working fluid, and mesh wick without changing the equivalent heated diameter. The results from this study can be used for predicting the heat transfer performance and operation limit of the structure-inserted heat pipe systems. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1456 / 1468
页数:13
相关论文
共 50 条
  • [1] Heat transfer performance of multiphase flow closed thermosyphon with a built-in pipe
    Xu, Xiaoping
    Shi, Jintao
    Jiang, Feng
    Li, Xiulun
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2014, 47 (10): : 928 - 933
  • [2] Heat Pipe Thermosyphon Heat Performance Calculation
    Novomestsky, Marcel
    Kapjor, Andrej
    Papucik, Stefan
    Siazik, Jan
    APPLICATION OF EXPERIMENTAL AND NUMERICAL METHODS IN FLUID MECHANICS AND ENERGY 2016: XX ANNIVERSARY OF INTERNATIONAL SCIENTIFIC CONFERENCE, 2016, 1745
  • [3] Flow Visualization inside Thermosyphon for Measuring Heat Transfer Limit
    Lee, Jungho
    Park, Jaebum
    Kim, Jinsub
    You, Seung M.
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2017, 139 (02):
  • [4] Performance of a heat pipe thermosyphon radiator
    Jebrail, FF
    Andrews, MJ
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1997, 21 (02) : 101 - 112
  • [5] Performance Characteristic of Thermosyphon Heat Pipe at Radiant Heat Source
    Hrabovsky, Peter
    Papucik, Stefan
    Kaduchova, Katarina
    APPLICATION OF EXPERIMENTAL AND NUMERICAL METHODS IN FLUID MECHANICS AND ENERGY 2016: XX ANNIVERSARY OF INTERNATIONAL SCIENTIFIC CONFERENCE, 2016, 1745
  • [6] Steady flow and heat transfer of a Sisko fluid in annular pipe
    Khan, M.
    Munawar, S.
    Abbasbandy, S.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (7-8) : 1290 - 1297
  • [7] Investigation of the performance of a new thermosyphon heat pipe design for applications heat transfer from liquid to gas
    Gurturk, Mert
    Kale, Cihangir
    Kok, Besir
    APPLIED THERMAL ENGINEERING, 2021, 186
  • [8] Experimental investigation of simultaneous electricity generation and heat transfer in a thermosyphon heat pipe
    Maleknezhad, Abolfazl
    Ghahremani, Amirreza
    Shafii, Mohammad Behshad
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 49
  • [9] Visualization experiment on boiling heat transfer and flow characteristics in separated heat pipe system
    Ding, Tao
    Cao, Han Wen
    He, Zhi Guang
    Li, Zhen
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2018, 91 : 423 - 431
  • [10] Turbulent heat transfer to separation nanofluid flow in annular concentric pipe
    Togun, Hussein
    Kazi, S. N.
    Badarudin, A.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2017, 117 : 14 - 25