Effect of post-cam design on the kinematics and contact stress of posterior-stabilized total knee arthroplasty

被引:3
|
作者
Lee, Jin-Ah [1 ]
Koh, Yong-Gon [2 ]
Kang, Kyoung-Tak [1 ]
机构
[1] Yonsei Univ, Dept Mech Engn, 50 Yonsei Ro, Seoul 03722, South Korea
[2] Yonsei Sarang Hosp, Joint Reconstruct Ctr, Dept Orthopaed Surg, 10 Hyoryeong Ro, Seoul, South Korea
关键词
Total knee arthroplasty; implant; kinematics; design; gait; TIBIAL POST; HIGH-FLEXION; WEAR; REPLACEMENT; PROSTHESIS; PERFORMANCE; MECHANISM; FRACTURE; MOTION; JOINT;
D O I
10.3233/BME-201097
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BACKGROUND: The post-cam mechanism in the posterior-stabilized (PS) implant plays an important role, such as durability and kinematic performances, in total knee arthroplasty (TKA). OBJECTIVE: The purpose of this study was to evaluate the difference in the kinematics and contact stress of five post-cam designs, which are flat-and-flat, curve-and-curve (concave), curve-and-curve (concave and convex), helical, and asymmetrical post-cam designs, using three-dimensional finite element models. METHODS: We designed the post-cam model with five different geometries. The kinematics, contact stress, and contact area were evaluated in the five post-cam designs under gait cycle loading conditions using the finite element method. RESULTS: There were no differences in the contact stress and area on the tibial insert in all designs. The largest internal rotation was shown in the swing phase for the helical design, and the largest tibial posterior translation was observed for the curve-and-curve (concave) design. The curve-and-curve (concave) design showed the lowest contact stress and the largest posterior tibial translation during the gait cycle. CONCLUSIONS: Considering the kinematics and contact stress, we found that the curve-and-curve (concave) design was more stable than other designs. From the results, we found the important factors of TKA implant considering stability and kinematics.
引用
收藏
页码:323 / 332
页数:10
相关论文
共 50 条
  • [1] Contact stress analysis of the conforming post-cam mechanism in posterior-stabilized total knee arthroplasty
    Akasaki, Yukio
    Matsuda, Shuichi
    Shimoto, Takeshi
    Miura, Hiromasa
    Higaki, Hidehiko
    Iwamoto, Yukihide
    JOURNAL OF ARTHROPLASTY, 2008, 23 (05): : 736 - 743
  • [2] Analysis of Weight-Bearing Kinematics of Posterior-Stabilized Total Knee Arthroplasty With Novel Helical Post-Cam Design
    Tsumori, Yohei
    Yoshiya, Shinichi
    Kurosaka, Masahiro
    Kobashi, Shoji
    Shibanuma, Nao
    Yamaguchi, Motoi
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08): : 1556 - 1561
  • [3] Post-Cam Design and Contact Stress on Tibial Posts in Posterior-Stabilized Total Knee Prostheses: Comparison Between a Rounded and a Squared Design
    Watanabe, Toshifumi
    Koga, Hideyuki
    Horie, Masafumi
    Katagiri, Hiroki
    Sekiya, Ichiro
    Muneta, Takeshi
    JOURNAL OF ARTHROPLASTY, 2017, 32 (12): : 3757 - 3762
  • [4] Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty
    Nakayama, K
    Matsuda, S
    Miura, H
    Higaki, H
    Otsuka, K
    Iwamoto, Y
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (04): : 483 - 488
  • [5] Post-cam mechanics and tibiofemoral kinematics: a dynamic in vitro analysis of eight posterior-stabilized total knee designs
    Arnout, N.
    Vanlommel, L.
    Vanlommel, J.
    Luyckx, J. P.
    Labey, L.
    Innocenti, B.
    Victor, J.
    Bellemans, J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (11) : 3343 - 3353
  • [6] Post-cam mechanics and tibiofemoral kinematics: a dynamic in vitro analysis of eight posterior-stabilized total knee designs
    N. Arnout
    L. Vanlommel
    J. Vanlommel
    J. P. Luyckx
    L. Labey
    B. Innocenti
    J. Victor
    J. Bellemans
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 3343 - 3353
  • [7] Intraoperative kinematic analysis of posterior stabilized total knee arthroplasty with asymmetric helical post-cam design
    Morooka, Takatoshi
    Okuno, Makiko
    Seino, Daisuke
    Iseki, Takuya
    Fukunishi, Shigeo
    Kobashi, Syoji
    Yoshiya, Shinichi
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (03): : 675 - 681
  • [8] Intraoperative kinematic analysis of posterior stabilized total knee arthroplasty with asymmetric helical post-cam design
    Takatoshi Morooka
    Makiko Okuno
    Daisuke Seino
    Takuya Iseki
    Shigeo Fukunishi
    Syoji Kobashi
    Shinichi Yoshiya
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 675 - 681
  • [9] Posterior tibial slope and anterior post-cam contact can change knee kinematics in extension in bi-cruciate stabilized total knee arthroplasty
    Hada, M.
    Mizu-uchi, H.
    Okazaki, K.
    Murakami, K.
    Kaneko, T.
    Higaki, H.
    Nakashima, Y.
    BONE & JOINT RESEARCH, 2020, 9 (11): : 761 - 767
  • [10] Influence of post-cam design on stresses on posterior-stabilized tibial posts
    Huang, Chang-Hung
    Liau, Jiann-Jong
    Huang, Chun-Hsiung
    Cheng, Cheng-Kung
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (450) : 150 - 156