Unifying Vascular Information in Intensity-Based Nonrigid Lung CT Registration

被引:0
|
作者
Cao, Kunlin [1 ]
Ding, Kai [2 ]
Christensen, Gary E. [1 ]
Raghavan, Madhavan L. [2 ]
Amelon, Ryan E. [2 ]
Reinhardt, Joseph M. [2 ]
机构
[1] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
来源
关键词
CUBIC B-SPLINE; IMAGE REGISTRATION; MUTUAL INFORMATION; VENTILATION;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Image registration plays an important role within pulmonary image analysis. Accurate registration is critical to post-analysis of lung mechanical properties. To improve registration accuracy, we utilize the rich information of vessel locations and shapes, and introduce a new similarity criterion, sum of squared vesselness measure difference (SSVMD). This metric is added to three existing intensity-based similarity criteria for nonrigid lung CT image registration to show its ability in improving matching accuracy. The registration accuracy is assessed by landmark error calculation and distance map visualization on vascular tree. The average landmark errors are reduced by over 20% and are within 0.7 mm after adding SSVMD constraint to three existing intensity-based similarity metrics. Visual inspection shows matching accuracy improvements in the lung regions near the thoracic cage and near the diaphragm. Experiments also show this vesselness constraint makes the Jacobian map of transformations physiologically more plausible and reliable.
引用
收藏
页码:1 / +
页数:2
相关论文
共 50 条
  • [1] Improving Intensity-Based Lung CT Registration Accuracy Utilizing Vascular Information
    Cao, Kunlin
    Ding, Kai
    Reinhardt, Joseph M.
    Christensen, Gary E.
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2012, 2012
  • [2] The adaptive bases algorithm for intensity-based nonrigid image registration
    Rohde, GK
    Aldroubi, A
    Dawant, BM
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (11) : 1470 - 1479
  • [3] Accelerated Nonrigid Intensity-Based Image Registration Using Importance Sampling
    Bhagalia, Roshni
    Fessler, Jeffrey A.
    Kim, Boklye
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (08) : 1208 - 1216
  • [4] Cadaver validation of intensity-based ultrasound to CT registration
    Penney, G. P.
    Barratt, D. C.
    Chan, C. S. K.
    Slomczykowski, M.
    Carter, T. J.
    Edwards, P. J.
    Hawkes, D. J.
    MEDICAL IMAGE ANALYSIS, 2006, 10 (03) : 385 - 395
  • [5] Registration of CT with PET: A Comparison of Intensity-Based Approaches
    Pereira, Gisele
    Domingues, Ines
    Martins, Pedro
    Abreu, Pedro H.
    Duarte, Hugo
    Santos, Joao
    COMBINATORIAL IMAGE ANALYSIS, IWCIA 2018, 2018, 11255 : 134 - 149
  • [6] Cadaver validation of intensity-based ultrasound to CT registration
    Penney, GP
    Barratt, DC
    Chan, CSK
    Slomczykowski, M
    Carter, TJ
    Edwards, PJ
    Hawkes, DJ
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2, 2005, 3750 : 1000 - 1007
  • [7] Unifying Encoding of Spatial Information in Mutual Information for Nonrigid Registration
    Zhuang, Xiahai
    Hawkes, David J.
    Ourselin, Sebastien
    INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 2009, 5636 : 491 - 502
  • [8] Extension of the ICP algorithm to nonrigid intensity-based registration of 3D volumes
    Feldmar, J
    Declerck, J
    Malandain, G
    Ayache, N
    COMPUTER VISION AND IMAGE UNDERSTANDING, 1997, 66 (02) : 193 - 206
  • [9] Nonrigid Registration of Lung CT Images Based on Tissue Features
    Zhang, Rui
    Zhou, Wu
    Li, Yanjie
    Yu, Shaode
    Xie, Yaoqin
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
  • [10] Linear Intensity-Based Image Registration
    Ahmad, Yasmin Mumtaz
    Sahran, Shahnorbanun
    Adam, Afzan
    Osman, Syazarina Sharis
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2018, 9 (12) : 211 - 217