Optimizing Image Reconstruction in SENSE Using GPU

被引:2
|
作者
Qazi, Sohaib A. [1 ]
Nasir, Saima [1 ]
Saeed, Abeera [1 ]
Omer, Hammad [1 ]
机构
[1] COMSATS Inst Informat Technol, Dept Elect Engn, Islamabad, Pakistan
关键词
MRI; IMPLEMENTATION;
D O I
10.1007/s00723-017-0951-4
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Parallel magnetic resonance imaging (MRI) (pMRI) uses multiple receiver coils to reduce the MRI scan time. To accelerate the data acquisition process in MRI, less amount of data is acquired from the scanner which leads to artifacts in the reconstructed images. SENSitivity Encoding (SENSE) is a reconstruction algorithm in pMRI to remove aliasing artifacts from the undersampled multi coil data and recovers fully sampled images. The main limitation of SENSE is computing inverse of the encoding matrix. This work proposes the inversion of encoding matrix using Jacobi singular value decomposition (SVD) algorithm for image reconstruction on GPUs to accelerate the reconstruction process. The performance of Jacobi SVD is compared with Gauss-Jordan algorithm. The simulations are performed on two datasets (brain and cardiac) with acceleration factors 2, 4, 6 and 8. The results show that the graphics processing unit (GPU) provides a speed up to 21.6 times as compared to CPU reconstruction. Jacobi SVD algorithm performs better in terms of acceleration in reconstructions on GPUs as compared to Gauss-Jordan method. The proposed algorithm is suitable for any number of coils and acceleration factors for SENSE reconstruction on real time processing systems.
引用
收藏
页码:151 / 164
页数:14
相关论文
共 50 条
  • [1] Optimizing Image Reconstruction in SENSE Using GPU
    Sohaib A. Qazi
    Saima Nasir
    Abeera Saeed
    Hammad Omer
    Applied Magnetic Resonance, 2018, 49 : 151 - 164
  • [2] MR image reconstruction using the GPU
    Schiwietz, Thomas
    Chang, Ti-chiun
    Speier, Peter
    Westermann, Ruediger
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [3] Ultrasound Beamforming and Image Reconstruction using CPU and GPU
    Boonleelakul, Wittawat
    Techavipoo, Udomchai
    Worasawate, Denchai
    Keinprasit, Rachaporn
    Sunpetchniyom, Treepop
    Sugino, Nobuhiko
    Chayapong, Pairash Thai
    2016 13TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2016,
  • [4] Optimizing Image Sharpening Algorithm on GPU
    Fan, Mengran
    Jia, Haipeng
    Zhang, Yunquan
    An, Xiaojing
    Cao, Ting
    2015 44TH INTERNATIONAL CONFERENCE ON PARALLEL PROCESSING (ICPP), 2015, : 230 - 239
  • [5] The Agile Library for Biomedical Image Reconstruction Using GPU Acceleration
    Freiberger, Manuel
    Knoll, Florian
    Bredies, Kristian
    Scharfetter, Hermann
    Stollberger, Rudolf
    COMPUTING IN SCIENCE & ENGINEERING, 2013, 15 (01) : 34 - 44
  • [6] Toward Optimal Computation of Ultrasound Image Reconstruction Using CPU and GPU
    Techavipoo, Udomchai
    Worasawate, Denchai
    Boonleelakul, Wittawat
    Keinprasit, Rachaporn
    Sunpetchniyom, Treepop
    Sugino, Nobuhiko
    Thajchayapong, Pairash
    SENSORS, 2016, 16 (12) : 2 - 17
  • [7] GPU acceleration of absolute EIT image reconstruction using simulated annealing
    Tavares, Renato Seiji
    Sato, Andre Kubagawa
    Martins, Thiago Castro
    Lima, Raul Gonzalez
    Guerra Tsuzuki, Marcos Sales
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2019, 52 : 445 - 455
  • [8] Digital Holographic Image Reconstruction and GPU Acceleration
    Lopez, Danielle
    Zhang, Shuqun
    Mazo, Ivan
    2016 IEEE 37TH SARNOFF SYMPOSIUM, 2016,
  • [9] Fast cone-beam CT image reconstruction using GPU hardware
    Yan, Guorui
    Tian, Jie
    Zhu, Shouping
    Dai, Yakang
    Qin, Chenghu
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2008, 16 (04) : 225 - 234
  • [10] Fast iterative image reconstruction using sparse matrix factorization with GPU acceleration
    Zhou, Jian
    Qi, Jinyi
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961