Experimental Study of Electrical Contact Nonlinearity and its Passive Intermodulation Effect

被引:13
|
作者
Zhang, Songchang [1 ]
Zhao, Xiaolong [1 ]
Cao, Zhi [1 ]
Zhang, Keyue [1 ]
Gao, Fan [1 ]
He, Yongning [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Microelect, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Surface topography; Copper; Integrated circuit modeling; Current density; Contact resistance; linearity; nonlinearity; oxidation; passive intermodulation (PIM); LOW-TEMPERATURE OXIDATION; RESISTANCE THEORY; ROUGH SURFACES; REFLECTOR; OXIDES; MODEL; XPS; CU;
D O I
10.1109/TCPMT.2019.2955283
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this article, the single-point electrical contact nonlinearity of the oxidation enhanced copper and its induced passive intermodulation (PIM) effect were systematically investigated. First, based on the composition analysis of the intentionally oxidized copper samples and the pristine ones, the electron potential barrier model across the contact interface was built. Then, based on an equivalent circuit model concluding a linear and nonlinear resistance, a total current equation based on the thermal emission mechanism was deduced and verified by performing a series of I-V measurements. When an oxide film is integrated, the linear current and the nonlinear current are comparable; when the oxide film was broken under an external force, the nonlinear current changes lightly, while the linear current increases sharply by more than two orders of magnitude. Therefore, we observed the transition process from the obvious nonlinear I-V characteristics to the dominant linear curves. Finally, the induced PIM behavior of the pristine and thermal oxidized single-point copper joints was investigated utilizing a specially designed near-field coupling PIM test system. As the pressure increases, the PIM level decrease with the joint pressure increases because both the contact resistance and the nonlinear current decrease. The measured PIM results are consistent with the obtained linear-nonlinear relation from the contact characteristics experiments. Experimentally, the total nonlinear current as the function of voltage drop across the contact interface, which is caused by the linear current, determines the induced PIM level.
引用
收藏
页码:424 / 434
页数:11
相关论文
共 50 条
  • [31] An experimental investigation on passive intermodulation at rectangular waveguide interfaces
    Vicente, C.
    Wolk, D.
    Hartnagel, H. L.
    Raboso, D.
    2006 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-5, 2006, : 242 - +
  • [32] Experimental Analysis of Passive Intermodulation at TNC Coaxial Connectors
    Wang, Rui
    Cui, Wanzhao
    Chen, Xiang
    Bai, Chunjiang
    Zhang, Na
    Li, Yun
    2017 11TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2017,
  • [33] Prediction of Passive Intermodulation Based on Tunneling Effect
    Li, Xiaoxiao
    Cui, Wanzhao
    PROCEEDINGS OF 2014 3RD ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION (APCAP 2014), 2014, : 895 - 897
  • [34] Effect of laminate properties on passive intermodulation generation
    Zelenchuk, D. E.
    Shitvov, A. P.
    Schuchinsky, A. G.
    2007 LOUGHBOROUGH ANTENNAS AND PROPAGATION CONFERENCE, PROCEEDINGS, 2007,
  • [35] Effect of load impedance on passive intermodulation measurements
    Hienonen, S
    Räisänen, AV
    ELECTRONICS LETTERS, 2004, 40 (04) : 245 - 247
  • [36] Temperature-Dependent Passive Intermodulation Effects in Coaxial Connectors With Dielectric Polarization Nonlinearity
    Fan, Wenhao
    Jin, Qiuyan
    Feng, Quanyuan
    Wei, Liping
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2025,
  • [37] Self-contact Introduced Passive Intermodulation Characterizations for Captured Springs
    Li, Jiangshuai
    Xia, Shengxuan
    Xu, Zhifei
    Xu, Yang
    Wang, Yansheng
    He, Yuchu
    Wu, Ken
    McDonnell, Nicholas
    Lee, Warren
    Zhou, Haicheng
    Fan, Jun
    Hwang, Chulsoon
    2021 JOINT IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, SIGNAL & POWER INTEGRITY, AND EMC EUROPE (EMC+SIPI AND EMC EUROPE), 2021, : 929 - 934
  • [38] An experimental study to determine electrical contact resistance
    Pradille, Christophe
    Bay, Francois
    Mocellin, Katia
    PROCEEDINGS OF THE FIFTY-SIXTH IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 2010, : 329 - 333
  • [39] Experimental analysis of passive intermodulation at waveguide flange bolted connections
    Vicente, Carlos
    Wolk, Dieter
    Hartnagel, Hans L.
    Gimeno, Benito
    Boria, Vicente E.
    Raboso, David
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2007, 55 (05) : 1018 - 1028
  • [40] Passive intermodulation model and experimental verification of cascaded microwave devices
    Li, Tuanjie
    Zhang, Kai
    Jiang, Jie
    INTERNATIONAL JOURNAL OF MICROWAVE AND WIRELESS TECHNOLOGIES, 2017, 9 (07) : 1481 - 1487