Novel intravascular macromolecular MRI contrast agent with generation-4 polyamidoamine dendrimer core: Accelerated renal excretion with coinjection of lysine

被引:37
|
作者
Kobayashi, H
Sato, N
Kawamoto, S
Saga, T
Hiraga, A
Ishimori, T
Konishi, J
Togashi, K
Brechbiel, MW
机构
[1] Kyoto Univ, Grad Sch Med, Hitachi Med Co, Chaired Dept Diagnost & Intervent Imaging,Sakyo K, Kyoto 6068507, Japan
[2] Kyoto Univ, Dept Nucl Med & Diagnost Imaging, Kyoto 6068507, Japan
[3] Kyoto Univ, Dept Radiol, Kyoto 6068507, Japan
[4] Otsu Municipal Hosp, Dept Radiol, Otsu, Shiga, Japan
[5] NCI, Radioimmune & Inorgan Chem Sect, Radiat Oncol Branch, NIH, Bethesda, MD 20892 USA
关键词
magnetic resonance imaging; angiography; lysine; contrast media; renal excretion;
D O I
10.1002/mrm.1214
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
One of the major limitations to macromolecular MRI contrast agents (MRI-CAs) is their slow clearance and associated decreased excretion of gadolinium (Gd(III)). The effect of coinjecting lysine to accelerate renal excretion of a macromolecular MRI-CA (generation-4 PAMAM (TM) dendrimer (G4D-(1B4M-Gd)(64))) was investigated. The biodistribution and urine and fecal excretion in athymic mice was evaluated with and without lysine coinjection. 3D-dynamic-micro-MRI with G4D-(1B4M-Gd)(64) was obtained with and without lysine coinjection, and the serial signal intensity (SI) change in the blood and organs was evaluated. When lysine was coinjected, urinary excretion of G4D-(1B4M-Gd)(64) increased 5.4-fold compared to that without lysine, resulting in decreased renal accumulation of G4D(iB4M-Gd)(64) from 150% to 40% injected dose per gram (P < 0.001). On dynamic MRI with G4D-(iB4M-Gd)(64), when lysine was coinjected, the kidney-to-blood SI ratio was significantly lower than that obtained without lysine (P < 0.001). When lysine was coinjected, the G4D-(iB4M-Gd)(64) was excreted from the kidney intact.
引用
收藏
页码:457 / 464
页数:8
相关论文
共 7 条
  • [1] Novel liver macromolecular MR contrast agent with a polypropylenimine diaminobutyl dendrimer core: Comparison to the vascular MR contrast agent with the polyamidoamine dendrimer core
    Kobayashi, H
    Kawamoto, S
    Saga, T
    Sato, N
    Hiraga, A
    Ishimori, T
    Akita, Y
    Mamede, MH
    Konishi, J
    Togashi, K
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) : 795 - 802
  • [2] Positive effects of polyethylene glycol conjugation to generation-4 polyamidoamine dendrimers as macromolecular MR contrast agents
    Kobayashi, H
    Kawamoto, S
    Saga, T
    Sato, N
    Hiraga, A
    Ishimori, T
    Konishi, J
    Togashi, K
    Brechbiel, MW
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) : 781 - 788
  • [3] Synthesis of Gold Nanoparticles with Polyamidoamine (Pamam) Generation 4 Dendrimer as Stabilizing Agent for CT Scan Contrast Agent
    Sutriyo
    Mutalib, A.
    Ristaniah
    Anwar, E.
    Radji, M.
    Pujiyanto, A.
    Purnamasari, P.
    Joshita, D.
    Adang, H. G.
    MACROMOLECULAR SYMPOSIA, 2015, 353 (01) : 96 - 101
  • [4] Comparison of the macromolecular MR contrast agents with ethylenediamine-core versus ammonia-core generation-6 polyamidoamine dendrimer
    Kobayashi, H
    Sato, N
    Kawamoto, S
    Saga, T
    Hiraga, A
    Haque, TL
    Ishimori, T
    Konishi, J
    Togashi, K
    Brechbiel, MW
    BIOCONJUGATE CHEMISTRY, 2001, 12 (01) : 100 - 107
  • [5] 3D-micro MR angiography of intratumoral microvasculature in experimental tumor models using a novel macromolecular MR contrast agent with generation-6 polyamidoamine dendrimer core
    Kobayashi, H
    Sato, N
    Saga, T
    Konishi, J
    Togashi, K
    Brechbiel, MW
    RADIOLOGY, 2000, 217 : 132 - 132
  • [6] Micro-MR angiography of normal and intratumoral vessels in mice using dedicated intravascular MR contrast agents with high generation of polyamidoamine dendrimer core: Reference to pharmacokinetic properties of dendrimer-based MR contrast agents
    Kobayashi, H
    Kawamoto, S
    Saga, T
    Sato, N
    Hiraga, A
    Konishi, J
    Togashi, K
    Brechbiel, MW
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (06) : 705 - 713
  • [7] Dynamic micro-MRI of liver micrometastasis with a novel liver macromolecular MR contrast agent DAB-Am64-(1B4M-Gd)64
    Kobayashi, H
    Saga, T
    Kawamoto, S
    Sato, N
    Hiraga, A
    Ishimori, T
    Konishi, J
    Togashi, K
    Brechbiel, MW
    ACADEMIC RADIOLOGY, 2002, 9 : S452 - S454