Incremental value of dual-energy CT to coronary CT angiography for the detection of significant coronary stenosis: comparison with quantitative coronary angiography and single photon emission computed tomography

被引:60
|
作者
Wang, Rui [1 ]
Yu, Wei [1 ]
Wang, Yongmei [1 ]
He, Yi [1 ]
Yang, Lin [1 ]
Bi, Tao [1 ]
Jiao, Jian [2 ]
Wang, Qian [2 ]
Chi, Liquan [3 ]
Yu, Yang [3 ]
Zhang, Zhaoqi [1 ]
机构
[1] Capital Med Univ, Anzhen Hosp, Dept Radiol, Beijing 100029, Peoples R China
[2] Capital Med Univ, Anzhen Hosp, Dept Nucl Med, Beijing 100029, Peoples R China
[3] Capital Med Univ, Anzhen Hosp, Dept Cardiol, Beijing 100029, Peoples R China
来源
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING | 2011年 / 27卷 / 05期
关键词
Dual energy computed tomography; Dual-source computed tomography; Coronary artery disease; Myocardial perfusion; ARTERY-DISEASE; DIAGNOSTIC PERFORMANCE; MYOCARDIAL-INFARCTION; INITIAL-EXPERIENCE; HEART-ASSOCIATION; METAANALYSIS; SPECT; COMMITTEE; ACCURACY; MDCT;
D O I
10.1007/s10554-011-9881-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine the value of dual-energy CT (DECT) and combined information of perfusion and angiography in diagnosing coronary artery disease (CAD), with single photon emission computed tomography (SPECT) and quantitative coronary angiography (QCA) as a reference standard. Thirty-four patients were enrolled in this study. DECT was used as a contrast-enhanced retrospectively ECG-gated scan protocol during the rest state and tubes were set at 140/100 kV. DECT angiography (DE-CTA) and DECT perfusion (DE-CTP) were calculated from two kV images. DE-CTP results were compared with SPECT and DE-CTA with QCA, respectively. The combined DE-CTP with DE-CTA data were compared to QCA in diagnosis of obstructive CAD (stenosis a parts per thousand yen 50%). DECT showed diagnostic image quality in 31 patients. Using SPECT as a reference, DE-CTP had sensitivity of 68%, specificity of 93%, and sensitivity of 81%, and specificity of 92% for identifying any type of perfusion deficits on the segment- and territory-based analysis, respectively. Using QCA as a reference standard, DE-CTA showed sensitivity of 82%, specificity of 91% and accuracy of 86% for detecting a parts per thousand yen50% coronary stenosis on the vessel-based analysis, whereas the combination of DE-CTA and DE-CTP gave sensitivity of 90%, specificity of 86% and accuracy of 88% for detecting a parts per thousand yen50% coronary stenosis, respectively. Combination of DE-CTP and DE-CTA may improve diagnostic performance compared to CTA alone for the diagnosis of significant coronary stenosis.
引用
收藏
页码:647 / 656
页数:10
相关论文
共 50 条
  • [1] Incremental value of dual-energy CT to coronary CT angiography for the detection of significant coronary stenosis: comparison with quantitative coronary angiography and single photon emission computed tomography
    Rui Wang
    Wei Yu
    Yongmei Wang
    Yi He
    Lin Yang
    Tao Bi
    Jian Jiao
    Qian Wang
    Liquan Chi
    Yang Yu
    Zhaoqi Zhang
    The International Journal of Cardiovascular Imaging, 2011, 27 : 647 - 656
  • [2] Impact of monochromatic coronary computed tomography angiography from single-source dual-energy CT on coronary stenosis quantification
    Stehli, Julia
    Clerc, Olivier F.
    Fuchs, Tobias A.
    Possner, Mathias
    Graeni, Christoph
    Benz, Dominik C.
    Buechel, Ronny R.
    Kaufmann, Philipp A.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (02) : 135 - 140
  • [3] Diagnostic Performance of Coronary CT Angiography, Stress Dual-Energy CT Perfusion, and Stress Perfusion Single-Photon Emission Computed Tomography for Coronary Artery Disease: Comparison with Combined Invasive Coronary Angiography and Stress Perfusion Cardiac MRI
    Chung, Hyun Woo
    Ko, Sung Min
    Hwang, Hweung Kon
    So, Young
    Yi, Jeong Geun
    Lee, Eun Jeong
    KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (03) : 476 - 486
  • [4] Coronary CT Angiography and Dual-Energy Computed Tomography in Ischemic Heart Disease Suspected Patients
    Mohammadzadeh, Ali
    Farzaneh, Mehdi
    Zahedmehr, Ali
    Kiani, Reza
    Shakiba, Madjid
    Borhani, Ali
    Rouzitalab, Mostafa
    Ahmadi, Samaneh
    Mohammadzadeh, Maryam
    ARCHIVES OF IRANIAN MEDICINE, 2019, 22 (07) : 376 - 383
  • [5] Findings of Single-Photon Emission Computed Tomography and Its Relation with Quantitative Coronary Angiography in Patients with Significant Stenosis of the Left Main Coronary Artery
    Kim, Hack-Lyoung
    Oh, So Won
    Lee, Hyunjong
    Kim, Hee Jun
    Kim, You Nui
    Lim, Woo-Hyun
    Seo, Jae-Bin
    Kim, Sang-Hyun
    Kim, Myung-A
    Zo, Joo-Hee
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (01) : 101 - 110
  • [6] Diagnostic Accuracy in Coronary Stenosis: Comparison Between Visual Score and Quantitative Analysis (Quantitative Computed Tomographic Angiography) in Coronary Angiography by Multidetector Computed Tomography-Coronary Angiography and Quantitative Analysis (Quantitative Coronary Angiography) in Conventional Coronary Angiography
    Malago, Roberto
    D'Onofrio, Mirko
    Tavella, Domenico
    Mantovani, William
    Brunelli, Silvia
    Pezzato, Andrea
    Caliari, Giuliana
    Nicoli, Lisa
    Benussi, Paolo
    Mucelli, Roberto Pozzi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (05) : 652 - 659
  • [7] 126 Comparison of coronary MR and CT angiography in detection of coronary stenosis with coronary calcification
    Xin Liu
    Christopher Francois
    David Tuite
    Debiao Li
    James Carr
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [8] Evaluation of coronary artery disease with coronary computed tomography angiography and single photon emission computed tomography
    Alexanderson, Erick E.
    Herrera, M.
    Calleja, R.
    Martinez, A. J.
    Ochoa, J. M.
    Alcantara, M.
    Meave, A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S39 - S39
  • [9] Quantification of Coronary Artery Calcium on the Basis of Dual-Energy Coronary CT Angiography
    Schwarz, Florian
    Nance, John W., Jr.
    Ruzsics, Balazs
    Bastarrika, Gorka
    Sterzik, Alexander
    Schoepf, U. Joseph
    RADIOLOGY, 2012, 264 (03) : 700 - 707
  • [10] ACCURACY OF CORONARY CT ANGIOGRAPHY IN PATIENTS WITH CORONARY STENTS: COMPARISON WITH QUANTITATIVE CORONARY ANGIOGRAPHY
    Malhotra, Pankaj
    Gheyath, Bashaer
    Han, Donghee
    Dey, Damini
    Hayes, Sean W.
    Friedman, John D.
    Thomson, Louise
    Kwan, Alan
    Berman, Daniel S.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 1505 - 1505