Preliminary design of safety and interlock system for indian test facility of diagnostic neutral beam

被引:6
|
作者
Tyagi, Himanshu [1 ]
Soni, Jignesh [2 ]
Yadav, Ratnakar [1 ]
Bandyopadhyay, Mainak [1 ]
Rotti, Chandramouli [1 ]
Gahlaut, Agrajit [2 ]
Joshi, Jaydeep [1 ]
Parmar, Deepak [1 ]
Bansal, Gourab [2 ]
Pandya, Kaushal [2 ]
Chakraborty, Arun [2 ]
机构
[1] Inst Plasma Res, ITER India, Gandhinagar, Gujarat, India
[2] Inst Plasma Res, Gandhinagar, Gujarat, India
关键词
Interlock; Safety; INTF; DNB and ITER;
D O I
10.1016/j.fusengdes.2016.05.017
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Indian Test Facility (INTF) is being built in Institute For Plasma Research to characterize Diagnostic Neutral Beam in co-operation with ITER Organization. INTF is a complex system which consists of several plant systems like beam source, gas feed, vacuum, cryogenics, high voltage power supplies, high power RF generators, mechanical systems and diagnostics systems. Out of these, several INTF components are ITER deliverable, that is, beam source, beam line components and power supplies. To ensure successful operation of INTF involving integrated operation of all the constituent plant systems a matured Data Acquisition and Control System (DACS) is required. The INTF DACS is based on CODAC platform following on PCDH (Plant Control Design Handbook) guidelines. The experimental phases involve application of HV power supplies (100 KV) and High RF power (similar to 800 KW) which will produce energetic beam of maximum power 6MW within the facility for longer durations. Hence the entire facility will be exposed tohigh heat fluxes and RF radiations. To ensure investment protection and to provide occupational safety for working personnel a matured Safety and Interlock system is required for INTF. The Safety and Interlock systems are high-reliability I&C systems devoted completely to the specific functions. These systems will be separate from the conventional DACS of INTF which will handle the conventional control and acquisition functions. Both, the Safety and Interlock systems are based on IEC 61511 and IEC 61508 standards as prescribed by the ITER PCDH guidelines. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:766 / 770
页数:5
相关论文
共 50 条
  • [1] Design of tomographic diagnostic system for Indian Test Facility (INTF) neutral beam injector
    Borah, D.
    Chattopadhyay, A. K.
    Bandyopadhyay, M.
    Deka, A. J.
    FUSION ENGINEERING AND DESIGN, 2019, 148
  • [2] An Indian test facility to characterise diagnostic neutral beam for ITER
    Singh, M. J.
    Bandyopadhyay, M.
    Rotti, C.
    Singh, N. P.
    Shah, Sejal
    Bansal, G.
    Gahlaut, A.
    Soni, J.
    Lakdawala, H.
    Waghela, Harshad
    Ahmed, I.
    Roopesh, G.
    Baruah, U. K.
    Chakraborty, A. K.
    FUSION ENGINEERING AND DESIGN, 2011, 86 (6-8) : 732 - 735
  • [3] Design of Data Acquisition and Control System for Indian Test Facility of Diagnostics Neutral Beam
    Soni, Jignesh
    Tyagi, Himanshu
    Yadav, Ratnakar
    Rotti, Chandramouli
    Bandyopadhyay, Mainak
    Bansal, Gourab
    Gahluat, Agrajit
    Sudhir, Dass
    Joshi, Jaydeep
    Prasad, Rambilas
    Pandya, Kaushal
    Shah, Sejal
    Parmar, Deepak
    Chakraborty, Arun
    FUSION ENGINEERING AND DESIGN, 2015, 96-97 : 961 - 965
  • [4] The neutral beam test facility cryopumping operation: Preliminary analysis and design of the cryogenic system
    Gravil, B.
    Henry, D.
    Dremel, M.
    Cordier, J. J.
    Hemsworth, R.
    Van Houtte, D.
    ICEC 20: PROCEEDINGS OF THE TWENTIETH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE, 2005, : 31 - 34
  • [5] Preliminary design of the control and data acquisition systems for the Neutral Beam Test Facility
    Luchetta, Adriano
    Barana, Oliviero
    Manduchi, Gabriele
    Taliercio, Cesare
    FUSION ENGINEERING AND DESIGN, 2009, 84 (7-11) : 1227 - 1232
  • [6] R&D status of the Indian test facility for ITER diagnostic neutral beam characterization
    Singh, M. J.
    Chakraborty, A. K.
    Bandyopadhyay, Mainak
    Joshi, Jaydeep
    Patel, Hitesh
    Pandya, Kaushal
    Shah, Sejal
    Gahlaut, Agrajit
    Yadav, Ashish
    Parmar, Deepak
    Sharma, Dheeraj
    Singh, Dhananjay
    Tyagi, Himanshu
    Joshi, Kaushal
    Nagaraju, M., V
    Bhuyan, Manas
    Patel, Milind
    Yadav, Ratnakar
    Pillai, Suraj
    Boilson, D.
    Chareyre, J.
    Schunke, B.
    Rotti, C.
    NUCLEAR FUSION, 2019, 59 (09)
  • [7] Safety systems in the ITER neutral beam test facility
    Dal Bello, Samuele
    Battistella, Manuela
    Grando, Luca
    Luchetta, Adriano
    Moressa, Modesto
    Breda, Mauro
    Svensson, Lennart
    Paolucci, Francesco
    Labate, Carmelo Vincenzo
    FUSION ENGINEERING AND DESIGN, 2019, 146 : 246 - 249
  • [8] Preliminary design of diagnostic system for negative neutral beam injector at ASIPP
    Xu, Yongjian
    Hu, Chundong
    Liang, Lizhen
    Xie, Yahong
    Jiang, Caichao
    Wei, Jianglong
    Tao, Ling
    Xie, Yuanlai
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (12):
  • [9] Functional safety assessment process for MITICA safety system in the ITER neutral beam test facility
    Grando, Luca
    Battistella, Manuela
    Dal Bello, Samuele
    Luchetta, Adriano
    Moressa, Modesto
    Munari, Silvia
    Gueccia, Alessandro
    Piccini, Michele
    FUSION ENGINEERING AND DESIGN, 2023, 193
  • [10] Diagnostics of the ITER neutral beam test facility
    Pasqualotto, R.
    Serianni, G.
    Sonato, P.
    Agostini, M.
    Brombin, M.
    Croci, G.
    Dalla Palma, M.
    De Muri, M.
    Gazza, E.
    Gorini, G.
    Pomaro, N.
    Rizzolo, A.
    Spolaore, M.
    Zaniol, B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02):