摘要
Three-dimensional (3D) bioprinting offers innovative research vectors for tissue engineering. However, commercially available bioprinting platforms can be cost prohibitive to small research facilities, especially in an academic setting. The goal is to design and fabricate a low-cost printing platform able to deliver cell-laden fluids with spatial accuracy along the X, Y, and Z axes of 0.1 mm. The bioprinter consists of three subassemblies: a base unit, a gantry, and a shuttle component. The platform utilizes four stepper motors to position along three axes and a fifth stepper motor actuating a pump. The shuttle and gantry are each driven along their respective horizontal axes via separate single stepper motor, while two coupled stepper motors are used to control location along the vertical axis. The current shuttle configuration allows for a 5 mL syringe to be extruded within a work envelope of 180 mm x 160 mm x 120 mm (X, Y, Z). The shuttle can easily be reconfigured to accommodate larger volume syringes. An attachment for a laser pen is located such that printing material may be light-activated pre-extrusion. Positional fidelity was established with calipers possessing a resolution to the nearest hundredth millimeter. The motors associated with the X and Y axes were calibrated to approximately 0.02mm per motor impulse. The Z axis has a theoretical step distance of similar to 51 nm, generating 0.04% error over a 10 mm travel distance. The A axis, or pump motor, has an impulse distance of 0.001 mm. The volume extruded by a single impulse is dictated by the diameter of the syringe used. With a 5 mL syringe possessing an inner diameter of 12.35 mm, the pump pushes as little as 0.119 mu L. While the Z axis is tuned to the highest resolution settings for the motor driver, the X, Y, and A axes can obtain higher or lower resolution via physical switches on the motor drivers.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Design of Low-Cost Photonic Crystal Based Three-Dimensional Invisibility Cloak
    Zheng, Geng
    Zhang, Hualiang
    Lin, Yuankun
    [J]. MICRO- AND NANOTECHNOLOGY SENSORS, SYSTEMS, AND APPLICATIONS III, 2011, 8031
  • [2] Low-Cost Three-Dimensional Modeling of Crop Plants
    Martinez-Guanter, Jorge
    Ribeiro, Angela
    Peteinatos, Gerassimos G.
    Perez-Ruiz, Manuel
    Gerhards, Roland
    Maria Bengochea-Guevara, Jose
    Machleb, Jannis
    Andujar, Dionisio
    [J]. SENSORS, 2019, 19 (13):
  • [3] Multimaterial and Multiscale Three-Dimensional Bioprinter
    Campbell, Jennifer
    McGuinness, Ian
    Wirz, Holger
    Sharon, Andre
    Sauer-Budge, Alexis F.
    [J]. Journal of Nanotechnology in Engineering and Medicine, 2015, 6 (02)
  • [4] Customizable Fabrication of Photothermal Microneedles with Plasmonic Nanoparticles Using Low-Cost Stereolithography Three-Dimensional Printing
    Ziesmer, Jill
    Sonden, Isabel
    Larsson, Justina Venckute
    Merkl, Padryk
    Sotiriou, Georgios A.
    [J]. ACS APPLIED BIO MATERIALS, 2024, : 4533 - 4541
  • [5] A Novel Low-Cost Three-Dimensional Printed Brace Design Method for Early Onset Scoliosis
    Li, Hongwei
    Yang, Zhangkai
    Li, Dichen
    Qiao, Feng
    [J]. JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2022, 16 (03):
  • [6] A Low-Cost and Compact Three-Dimensional Microwave Holographic Imaging System
    Wu, Hailun
    Amineh, Reza K.
    [J]. ELECTRONICS, 2019, 8 (09)
  • [7] Three-Dimensional Microscopic Surgical Videos: A Novel and Low-cost System
    Campero, Alvaro
    Baldoncini, Matias
    Villalonga, Juan F.
    Abarca-Olivas, Javier
    [J]. WORLD NEUROSURGERY, 2019, 132 : 188 - 196
  • [8] Low-cost optoelectronic system for three-dimensional artwork texture measurement
    Spagnolo, GS
    Ambrosini, D
    Paoletti, D
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2004, 13 (03) : 388 - 394
  • [9] Low-cost three-dimensional imaging system combining fluorescence and ultrasound
    Li, Baoqiang
    Abran, Maxime
    Matteau-Pelletier, Carl
    Rouleau, Leonie
    Lam, Tina
    Sharma, Rishi
    Rheaume, Eric
    Kakkar, Ashok
    Tardif, Jean-Claude
    Lesage, Frederic
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (12)
  • [10] Three-dimensional scanning system based on a low-cost infrared sensor
    Braun, Joao
    Lima, Jose
    Pereira, Ana, I
    Rocha, Claudia
    Costa, Paulo
    [J]. 2021 26TH IEEE INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES AND FACTORY AUTOMATION (ETFA), 2021,