Comparative analysis of stability limitations in weak grid-connected synchronous generator, VSC, and DFIG systems considering the power flow control dynamics

被引:7
|
作者
Wang, Dong [1 ,2 ]
Hou, Yunhe [1 ,2 ]
Hu, Jiabing [3 ]
机构
[1] Univ Hong Kong, Dept Elect & Elect Engn, Hong Kong, Peoples R China
[2] Univ Hong Kong, Shenzhen Inst Res & Innovat, Shenzhen, Peoples R China
[3] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Hubei, Peoples R China
基金
美国国家科学基金会;
关键词
power generation faults; load flow control; invertors; power control; power generation control; asynchronous generators; power grids; voltage-source convertors; reduced order systems; weak grid conditions; voltage source converter-based high-voltage DC; partial VSC; induction generator systems; instabilities; possible unified explanation; instability issues; DFIG systems; outer power flow controls; reduced-order models; active power control loops; grid strength decrease; right-half-plane zeros; stability boundary; comparative analysis; stability limitations; weak grid-connected synchronous generator; power flow control dynamics; conventional power systems; synchronous generators; stability issues; SG instability mechanism; identified RHPZ limitations; RHPZ; SMALL-SIGNAL STABILITY;
D O I
10.1049/iet-rpg.2018.5001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the conventional power systems, the synchronous generators (SGs) are known to suffer stability issues under weak grid conditions. Recently, similar problems are observed in the inverter interfaced systems, including the full voltage source converter (VSC)-based high-voltage DC, and partial VSC interfaced doubly fed induction generator (DFIG) systems, but the root causes of these instabilities in reality are not completely understood yet. This study aims to provide a possible unified explanation for the origin of these instability issues. With the experiences of SG's instability mechanism, for the VSC and DFIG systems, the dynamics of outer power flow controls are mainly focused, and the reduced-order models are parallelly presented first. Then, centralised around the active power control loops of these systems for analysis, it is found that an open-loop zero will move to the right half plane with grid strength decrease. The borders for the occurrence of right-half-plane zeros (RHPZs) are analytically derived. Further, a general interpretation regarding these identified RHPZs' limitations, including the adverse phase lag effect on stability and the attraction effect on the stability boundary, is illustrated. In addition, a uniform explanation for the origin of the RHPZs in these systems is also provided. Time-domain simulations are conducted to validate the analysis.
引用
收藏
页码:94 / 102
页数:9
相关论文
共 50 条
  • [1] Stability Analysis of Power Control Outer Loop of Grid-connected VSC Under Weak Connection Conditions
    Ren B.
    Sun R.
    Li Q.
    Gan D.
    Zhou Q.
    Wang C.
    [J]. Gaodianya Jishu/High Voltage Engineering, 2022, 48 (02): : 762 - 771
  • [2] Control Strategy and Corresponding Parameter Analysis of a Virtual Synchronous Generator Considering Frequency Stability of Wind Power Grid-Connected System
    Liu, Yingming
    Wang, Hanbo
    Wang, Xiaodong
    Guo, Guoxian
    Jing, Hejun
    [J]. ELECTRONICS, 2022, 11 (18)
  • [3] Modeling and Stability Analysis of Grid-Connected VSC Considering Alternating-Voltage Control
    Mukherjee, Nilanjan
    Sarkar, Sudeshna
    [J]. 2023 33RD AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE, AUPEC, 2023,
  • [4] Stability Analysis of Grid-connected Inverter in Weak Grid Systems
    Chen, Xin
    Gong, Chun Yin
    Cheng, Lin
    [J]. ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 1514 - 1518
  • [5] SMALL DISTURBANCE STABILITY CONSTRAINED OPTIMAL POWER FLOW ALGORITHM OF PHOTOVOLTAIC GRID-CONNECTED POWER SYSTEMS WITH VIRTUAL SYNCHRONOUS GENERATOR
    Li, Shenghu
    Gong, Junwei
    Xia, Weijian
    Yao, Jiawei
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2024, 45 (12): : 146 - 153
  • [6] An Improved Feedforward Control Method Considering PLL Dynamics to Improve Weak Grid Stability of Grid-Connected Inverters
    Zhang, Xueguang
    Xia, Danni
    Fu, Zhichao
    Wang, Gaolin
    Xu, Dianguo
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (05) : 5143 - 5151
  • [7] Stability Analysis of a Grid-Connected DFIG Operating in Sub-synchronous and Super-synchronous Conditions
    Lazar, Amal
    Kotian, Shashidhara Mecha
    [J]. 2022 IEEE INTERNATIONAL POWER AND RENEWABLE ENERGY CONFERENCE, IPRECON, 2022,
  • [8] Small Signal Stability Analysis Considering Grid-Connected Wind Farms of DFIG Type
    Wang, Chen
    Shi, Libao
    Wang, Liming
    Ni, Yixin
    [J]. 2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 4050 - 4055
  • [9] Maximum Power Control of Grid-connected DFIG-Based Wind Systems
    Sylla, Abdoulaye Mamadie
    Doumbia, Mamadou Lamine
    [J]. 2012 IEEE ELECTRICAL POWER AND ENERGY CONFERENCE (EPEC), 2012, : 267 - 273
  • [10] Damping Analysis of Outer Control Loops and Impacts on Stability of Grid-Connected VSC
    Zhao, Boyuan
    Chen, Lei
    Min, Yong
    Yu, Guangyuan
    Yin, Aihui
    [J]. 2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 1356 - 1361