Effect of impression materials on hybridized dentin

被引:5
|
作者
Nahon, M [1 ]
Dentkos, TR [1 ]
Nelson, SK [1 ]
Gardner, FM [1 ]
Rillman, EA [1 ]
机构
[1] Med Coll Georgia, Sch Dent, Dept Oral Rehabil, Prosthodont Residency Program, Augusta, GA 30912 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2001年 / 85卷 / 06期
关键词
D O I
10.1067/mpr.2001.116169
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Tooth sensitivity after crown preparation is not an uncommon complication. For dentin bonding agents to be effective in presenting postoperative sensitivity, they must remain intact throughout the fixed prosthodontic procedures. Purpose, This study evaluated, by analyzing the change in dentin permeability, whether a dentin bonding agent was removed from the surface of prepared teeth in the process of making: an impression. Material and methods. Eighty extracted human molars were cut horizontally apical to the cemento-enamel junction and horizontally through the middle of the clinical crown. The specimens were prepared to measure dentin permeability (fluid flow rate, Lp). The specimens (n = 40) were randomly assigned to either the primer-only group (PO) or the primer + adhesive group (PA). Five difficult impression materials were tested: vinyl polysiloxane, polyether, polysulfide, irreversible hydrocolloid, and reversible hydrocolloid. Dentinal permeability was measured after Smear layer removal (control, etched Lp = E.Lp), after coating the dentin with either PO or PA (coated Lp = CLp), and again after making an impression (impression Lp = ILp). A 1-way ANOVA of differences, followed by a Student-Newman-Keuls test (alpha=.05), was performed to compare the ELp, CLp, and ILp, values. Results. A statistically significant difference was Found between the CLp and ELp for all 5 impression materials in both groups (PO and PA). No difference was found between the CLp and ILp values for any of the impression materials. No significant differences were found between any of the 5 impression materials or either of the dentin surface treatments (PO or PA) when measuring the CLp and ILp. Conclusion. The dentin bonding agent had a significant effect in decreasing the Lp of the treated specimens. None of the impression materials significantly affected the measured CLp. There was no significant difference between the PO or PA (CLp) values.
引用
收藏
页码:568 / 574
页数:7
相关论文
共 50 条
  • [1] DENTIN SURFACE REPRODUCTION WITH HYDROPHILIC AND HYDROPHOBIC IMPRESSION MATERIALS
    TAKAHASHI, H
    FINGER, WJ
    [J]. DENTAL MATERIALS, 1991, 7 (03) : 197 - 201
  • [2] INTERACTIONS BETWEEN IMPRESSION MATERIALS AND IMMEDIATE DENTIN SEALING
    Magne, Pascal
    Nielsen, Brik
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2009, 102 (05): : 298 - 305
  • [3] IMPRESSION MATERIALS - EFFECT OF HYDROPHILICITY AND VISCOSITY ON ABILITY TO DISPLACE WATER FROM DENTIN SURFACES
    PEUTZFELDT, A
    ASMUSSEN, E
    [J]. SCANDINAVIAN JOURNAL OF DENTAL RESEARCH, 1988, 96 (03): : 253 - 259
  • [4] Function of hybridized dentin created in subsurface of dentin
    Nakabayashi, N
    [J]. DENTIN/PULP COMPLEX, 1996, : 202 - 208
  • [5] EFFECT OF MOISTURE ON POLYETHER IMPRESSION MATERIALS
    HEMBREE, JH
    NUNEZ, LJ
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1974, 89 (05): : 1134 - 1136
  • [6] The effect of temperature on elastomeric impression materials.
    Hare, RV
    [J]. JOURNAL OF DENTAL RESEARCH, 2000, 79 : 446 - 446
  • [7] ELASTOMERIC IMPRESSION MATERIALS - EFFECT OF BULK ON ACCURACY
    EAMES, WB
    SIEWEKE, JC
    WALLACE, SW
    ROGERS, LB
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1979, 41 (03): : 304 - 307
  • [8] ELASTOMERIC IMPRESSION MATERIALS - EFFECT OF BULK ON ACCURACY
    SIEWEKE, JC
    EAMES, WB
    WALLACE, SW
    [J]. JOURNAL OF DENTAL RESEARCH, 1977, 56 : B147 - B147
  • [9] Preparation of the hybridized dentin and the function in dentistry.
    Nakabayashi, N
    [J]. JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1270 - 1270
  • [10] THE EFFECT OF DISINFECTION REGIMES ON THE WETTABILITY OF IMPRESSION MATERIALS
    MILLAR, BJ
    NESBIT, M
    WOOD, D
    BUBB, N
    [J]. JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 899 - 899