Estimation of dynamic time activity curves from dynamic cardiac SPECT imaging

被引:2
|
作者
Hossain, J. [1 ]
Du, Y. [1 ]
Links, J. [2 ]
Rahmim, A. [3 ]
Karakatsanis, N. [3 ]
Akhbardeh, A. [4 ]
Lyons, J. [5 ,6 ]
Frey, E. C. [1 ]
机构
[1] Johns Hopkins Med Inst, Russell H Morgan Dept Radiol & Radiol Sci, Div Med Imaging Phys, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Div Mol & Translat Toxicol, Bloomberg Sch Publ Hlth, Baltimore, MD 21205 USA
[3] Johns Hopkins Med Inst, Russell H Morgan Dept Radiol & Radiol Sci, Div Nucl Med, Baltimore, MD 21287 USA
[4] Johns Hopkins Med Inst, Russell H Morgan Dept Radiol & Radiol Sci, MRI Res, Baltimore, MD 21287 USA
[5] Brigham & Womens Hosp, Dept Neurol, Boston, MA 02115 USA
[6] Harvard Univ, Sch Med, Boston, MA 02115 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 08期
关键词
dynamic spect; Tc-99m-teboroxime; cardiac imaging; coronary flow reserve; MYOCARDIAL BLOOD-FLOW; SCATTER RESPONSE FUNCTION; ORGAN ACTIVITY ESTIMATION; PROJECTOR-BACKPROJECTOR; QUANTITATIVE SPECT; PROCESSING METHODS; INPUT FUNCTION; COMPENSATION; PLANAR; QUANTIFICATION;
D O I
10.1088/0031-9155/60/8/3193
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Whole-heart coronary flow reserve (CFR) may be useful as an early predictor of cardiovascular disease or heart failure. Here we propose a simple method to extract the time-activity curve, an essential component needed for estimating the CFR, for a small number of compartments in the body, such as normal myocardium, blood pool, and ischemic myocardial regions, from SPECT data acquired with conventional cameras using slow rotation. We evaluated the method using a realistic simulation of Tc-99m-teboroxime imaging. Uptake of Tc-99m-teboroxime based on data from the literature were modeled. Data were simulated using the anatomically-realistic 3D NCAT phantom and an analytic projection code that realistically models attenuation, scatter, and the collimator-detector response. The proposed method was then applied to estimate time activity curves (TACs) for a set of 3D volumes of interest (VOIs) directly from the projections. We evaluated the accuracy and precision of estimated TACs and studied the effects of the presence of perfusion defects that were and were not modeled in the estimation procedure. The method produced good estimates of the myocardial and blood-pool TACS organ VOIs, with average weighted absolute biases of less than 5% for the myocardium and 10% for the blood pool when the true organ boundaries were known and the activity distributions in the organs were uniform. In the presence of unknown perfusion defects, the myocardial TAC was still estimated well (average weighted absolute bias <10%) when the total reduction in myocardial uptake (product of defect extent and severity) was <= 5%. This indicates that the method was robust to modest model mismatch such as the presence of moderate perfusion defects and uptake nonuniformities. With larger defects where the defect VOI was included in the estimation procedure, the estimated normal myocardial and defect TACs were accurate (average weighted absolute bias approximate to 5% for a defect with 25% extent and 100% severity).
引用
收藏
页码:3193 / U501
页数:16
相关论文
共 50 条
  • [1] PATHOPHYSIOLOGIC INTERPRETATION OF TIME ACTIVITY CURVES IN DYNAMIC BONE IMAGING
    MCCULLOUGH, RW
    GANDSMAN, EJ
    CLINICAL NUCLEAR MEDICINE, 1988, 13 (07) : 517 - 524
  • [2] Dynamic cardiac SPECT imaging using a stationary SPECT camera
    Maddula, R
    Clackdoyle, R
    Roberts, J
    Di Bella, E
    Fu, ZW
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3165 - 3169
  • [3] Effects of scatter modeling on time-activity curves estimated directly from dynamic SPECT projections
    Reutter, BW
    Gullberg, GT
    Huesman, RH
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2695 - 2699
  • [4] PHYSIOLOGIC INTERPRETATION OF TIME-ACTIVITY CURVES IN DYNAMIC BONE IMAGING
    MCCULLOUGH, RW
    GANDSMAN, EJ
    CLINICAL NUCLEAR MEDICINE, 1988, 13 (01) : 71 - 71
  • [5] DIAGNOSING OSTEOMYELITIS BY USING TIME ACTIVITY CURVES IN DYNAMIC BONE IMAGING
    MCCULLOUGH, RW
    MIKOLICH, D
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1988, 14 (5-6): : 324 - 324
  • [6] Small-animal SPECT dynamic cardiac imaging
    Johnson, Lindsay
    Guerraty, Marie
    Blankemeyer, Eric
    Mankoff, David
    Rader, Daniel
    Metzler, Scott
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [7] Dynamic imaging with a novel dedicated cardiac SPECT system
    Huang, Qiu
    Boutchko, Rostyslav
    Reutter, Bryan
    Gullberg, Grant
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [8] Direct extraction of tomographic time activity curves from dynamic SPECT projections using factor analysis.
    Sitek, A
    Di Bella, E
    Gullberg, GT
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 144P - 144P
  • [9] Statistically efficient estimation of kinetic parameters in dynamic cardiac SPECT
    Kadrmas, DJ
    Di Bella, EVR
    Gullberg, GT
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 144P - 144P
  • [10] Accuracy and precision of compartmental model parameters obtained from directly estimated dynamic SPECT time-activity curves
    Reutter, BW
    Gullberg, GT
    Huesman, RH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (01) : 170 - 176