Automatic program for peak detection and deconvolution of multi-overlapped chromatographic signals -: Part II:: Peak model and deconvolution algorithms

被引:73
|
作者
Vivó-Truyols, G
Torres-Lapasió, JR
van Nederkassel, AM
Vander Heyden, Y
Massart, DL
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Burjassot, Spain
[2] Vrije Univ Brussels, Dept Pharmaceut & Biomed Anal, B-1090 Brussels, Belgium
关键词
peak deconvolution; chromatographic one-way signals; monolithic silica; genetic algorithms;
D O I
10.1016/j.chroma.2005.03.072
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Several interlinked algorithms for peak deconvolution by non-linear regression are presented. These procedures, together with the peak detection methods outlined in Part I, have allowed the implementation of an automatic method able to process multi-overlapped signals, requiring little user interaction. A criterion based on the evaluation of the multivariate selectivity of the chromatographic signal is used to auto-select the most efficient deconvolution procedure for each chromatographic situation. In this way, non-optimal local solutions are avoided in cases of high overlap, and short computation times are obtained in situations of high resolution. A new algorithm, fitting both the original signal and the second derivatives is proved to avoid local optima in intermediate coelution situations. This allows achieving the global optimum without the need of background knowledge by the user. A previously reported peak model, a Gaussian with a polynomial standard deviation whose complexity can be modulated to enhance the fitting quality, was applied. However, the original formulation was modified to account baseline outside the peak region. Also, the optimal model complexity was auto-selected via error propagation theory. The method is able to process simultaneously several related chromatograms. The software was tested with both simulated and experimental chromatograms obtained with monolithic silica columns. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:146 / 155
页数:10
相关论文
共 6 条
  • [1] Automatic program for peak detection and deconvolution of multi-overlapped chromatographic signals -: Part I:: Peak detection
    Vivó-Truyols, G
    Torres-Lapasió, JR
    van Nederkassel, AM
    Vander Heyden, Y
    Massart, DL
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1096 (1-2) : 133 - 145
  • [2] ACCURACY OF PEAK DECONVOLUTION ALGORITHMS WITHIN CHROMATOGRAPHIC INTEGRATORS
    PAPAS, AN
    TOUGAS, TP
    ANALYTICAL CHEMISTRY, 1990, 62 (03) : 234 - 239
  • [3] Automatic peak recognition and rapid resolution of chromatographic signals with a self-compiling program
    Liu Mingming
    Xia Bingle
    Yang Jun
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2009, 27 (03) : 351 - 355
  • [4] Algorithms for time-dependent chromatographic peak areas - II. Resolution of overlapped chromatograms for two- and three-component samples
    Jin, DH
    Pardue, HL
    ANALYTICA CHIMICA ACTA, 2000, 422 (01) : 11 - 20
  • [5] Kinetic analysis of diesel particulate matter oxidation using a multi-step reaction model, components peak deconvolution, and isoconversional methods
    Sawatmongkhon, Boonlue
    Promhuad, Punya
    Wongkhorsub, Chonlakarn
    Wongchang, Thawatchai
    Sukjit, Ekarong
    Theinnoi, Nathinee
    Theinnoi, Kampanart
    FUEL, 2025, 390
  • [6] Multi-resolution Linear Model Comparison for Detection of Dicrotic Notch and Peak in Blood Volume Pulse Signals
    Blazek, Rudolf B.
    Lee, Chien-Cheng
    ANALYSIS OF BIOMEDICAL SIGNALS AND IMAGES, 2010, : 378 - 386