SPECTCT cerebral perfusion scintigraphy; is the low-dose CT component of diagnostic value?

被引:10
|
作者
Sulkin, T. V. C. [1 ]
Cousens, C. [1 ]
机构
[1] Royal Cornwall Hosp, Dept Clin Imaging, Truro, Cornwall, England
关键词
D O I
10.1016/j.crad.2007.08.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To assess the potential diagnostic value of the Low-dose computed tomography (CT) component of dual-examination single photon emission CT and CT (SPECTCT) cerebral perfusion studies. METHOD AND MATERIALS: Two hundred and forty consecutive 99 mTc hexamethylpropytene amine oxime (HMPAO) SPECTCT studies were considered for inclusion. The images were acquired on a hybrid dual-head gamma camera/low-dose CT system. The CT component had a fixed tube current of 2.5 mA. The CT section thickness was 5 mm and total acquisition time approximately 7.5 min. Studies in which no CT images were acquired, or those excessively degraded by movement artefact were excluded. The CT images of each of the remaining studies were retrospectively reviewed and categorized as normal or abnormal. Details of the abnormalities were recorded. RESULTS: Fifteen of the 240 studies were excluded as no CT images were obtained. A further 14 were excluded as they were considered excessively degraded by movement artefact. A single abnormality was demonstrated on 48 (23%), and two abnormalities on four (2%) of the remaining 211 studies. The most common abnormal findings were low attenuation in the deep cortical white matter (n = 22), infarcts (n = 12), cerebral atrophy (n = 7), dilated ventricles (n = 5), basal ganglia calcification (n 4), and post-surgical change (n = 3). Other findings included a chronic sub-dural haematoma, a meningioma, and a posterior fossa cyst. Previous cerebral, imaging was available for comparison in 31% of cases. There was 85% concordance between previous imaging and the tow-dose CT images. CONCLUSION: Twenty-five percent of the tow-dose CT images in this study demonstrated abnormalities. Therefore the CT component of cerebral perfusion SPECTCT investigations should be routinely reported in their own right. (C) 2007 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:289 / 298
页数:10
相关论文
共 50 条
  • [1] Low-dose cerebral CT perfusion imaging (CTPI) of senile dementia: Diagnostic performance
    Tang, Zhen
    Chen, Feng
    Huang, Jie
    Shi, Linghua
    Gong, H. T.
    Fu, Hongmei
    Qu, Zhengwan
    Pi, Xiaoling
    ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2013, 56 (01) : 61 - 67
  • [2] Performance of Low-Dose Perfusion Scintigraphy and CT Pulmonary Angiography for Pulmonary Embolism in Pregnancy
    Sheen, Jean-Ju
    Haramati, Linda B.
    Natenzon, Anna
    Ma, Hong
    Tropper, Pamela
    Bader, Anna S.
    Freeman, Leonard M.
    Bernstein, Peter S.
    Moadel, Renee M.
    CHEST, 2018, 153 (01) : 152 - 160
  • [3] Assessment of cerebral Vasospasm by using using Low-dose Volume Perfusion CT
    Lorenz, Judith
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2019, 191 (01): : 21 - +
  • [4] Diagnostic accuracy of myocardial perfusion SPECT with low-dose CT attenuation correction
    Kubinyi, J.
    Kupka, K.
    Krizova, H.
    Danzig, V.
    Kotalova, D.
    Rysova, L.
    Samal, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S271 - S271
  • [5] Diagnostic Accuracy of Simulated Low-Dose Perfusion CT to Detect Cerebral Perfusion Impairment after Aneurysmal Subarachnoid Hemorrhage: A Retrospective Analysis
    Afat, Saif
    Brockmann, Carolin
    Nikoubashman, Omid
    Mueller, Marguerite
    Thierfelder, Kolja M.
    Brockmann, Marc A.
    Nikolaou, Konstantin
    Wiesmann, Martin
    Kim, Jong Hyo
    Othman, Ahmed E.
    RADIOLOGY, 2018, 287 (02) : 643 - 650
  • [6] The Added Value of Low-Dose CT Component of V/Q SPECT/CT: A Meta Analysis
    Gunalp, B.
    Ince, S.
    Ayan, A.
    Alagoz, E.
    Okuyucu, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S829 - S829
  • [7] Local attenuation curve optimization framework for high quality perfusion maps in low-dose cerebral perfusion CT
    Van Nieuwenhove, Vincent
    Van Eyndhoven, Geert
    Batenburg, K. Joost
    Buls, Nico
    Vandemeulebroucke, Jef
    De Beenhouwer, Jan
    Sijbersa, Jan
    MEDICAL PHYSICS, 2016, 43 (12) : 6429 - 6438
  • [8] Fractional scan algorithms for low-dose perfusion CT
    Hsieh, J
    Wei, YC
    Wang, G
    MEDICAL PHYSICS, 2004, 31 (05) : 1254 - 1257
  • [9] Low-dose CT perfusion with projection view sharing
    Martin, Thomas
    Hoffman, John
    Alger, Jeff R.
    McNitt-Gray, Michael
    Wang, Danny J. J.
    MEDICAL PHYSICS, 2018, 45 (01) : 101 - 113
  • [10] SDCNET: SMOOTHED DENSE-CONVOLUTION NETWORK FOR RESTORING LOW-DOSE CEREBRAL CT PERFUSION
    Liu, Peng
    Fang, Ruogu
    2018 IEEE 15TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2018), 2018, : 349 - 352