MLC positioning checks and calibration with a portal imaging system

被引:1
|
作者
Schiefer, Hans [1 ]
Seelentag, Wolf W. [1 ]
Roth, Jakob [2 ]
Krusche, Bernd [3 ]
机构
[1] Klin Radioonckol, Kantonsspital St Gallen, CH-9007 St Gallen, Switzerland
[2] Univ Tsspital Basel, Basel, Switzerland
[3] Univ Basel, Inst Phys, CH-4003 Basel, Switzerland
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2008年 / 18卷 / 01期
关键词
MLC; check; EPID; marker;
D O I
10.1016/j.zemedi.2007.09.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For checking the leaf positions of a MLC (Multi Leaf Collimator) images are acquired with an EPID (Electronic Portal Imaging Device) and then evaluated with a programme (MLC check) developed in-house. During image acquisition a Perspex tray with two metal markers of known position (in the radiation field) is inserted in the satellite tray holder. After determination of the marker positions within the image coordinate system, the image can be transformed to the radiation field coordinate system. This allows the exact determination of the leaf tip positions relative to the radiation field. This evaluation can be applied to images of arbitrary field shapes, provided they were acquired in the same geometry (EPID position, gantry and collimator angles). The entire measurement procedure is based on images in bmp (Windows Bitmap) format, with a 1024 x 1024 matrix and a pixel depth of 24 bit (8 bit per color channel). A suitable marker plate can be manufactured without sophisticated workload; thus the method may be easily and cost effectively adapted at other locations.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 50 条
  • [1] Calibration of MLC leaf positions with an electronic portal imaging device for IMRT delivery
    Chen, H
    Yang, J
    Stapleton, P
    Murphy, S
    MEDICAL PHYSICS, 2002, 29 (06) : 1262 - 1262
  • [2] Comparison of a MLC calibration method using a diode array and electronic portal imaging device
    Simon, T.
    Fox, C.
    Li, J.
    Palta, I.
    Simon, W.
    Liu, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2337 - 2337
  • [3] The maximal accessible positioning accuracy of a modern electronic portal imaging system?
    Sweeney, RA
    Schiestl, B
    Eichberger, P
    Wegmayr, A
    Auberger, T
    Lukas, P
    STRAHLENTHERAPIE UND ONKOLOGIE, 2005, 181 : 85 - 86
  • [4] Design and calibration of a robotic needle positioning system for small animal imaging applications
    Waspe, A
    Cakiroglu, HJ
    Lacefield, J
    Fenster, A
    MEDICAL PHYSICS, 2005, 32 (06) : 2133 - 2133
  • [5] Verification of dynamic MLC beam delivery using electronic portal imaging
    Partridge, M
    Symonds-Tayler, JRN
    Evans, PM
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 556 - 557
  • [6] Calibration: Sanity checks
    Phillip Reu
    Experimental Techniques, 2014, 38 : 1 - 2
  • [7] Calibration: Sanity Checks
    Reu, Phillip
    EXPERIMENTAL TECHNIQUES, 2014, 38 (02) : 1 - 2
  • [8] Algorithm for calibration of the electromagnetic positioning system
    Tkhorenko, M. Yu.
    AUTOMATION AND REMOTE CONTROL, 2016, 77 (04) : 687 - 696
  • [9] Algorithm for calibration of the electromagnetic positioning system
    M. Yu. Tkhorenko
    Automation and Remote Control, 2016, 77 : 687 - 696
  • [10] AUTOMATED QUALITY CONTROL OF THE MLC PERFORMANCE USING AN ELECTRONIC PORTAL IMAGING DEVICE
    De Brabandere, M.
    Hrbacek, J.
    Swinnen, A.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S381 - S381