Study on the temperature characteristics of LPFG magnetic field sensor based on magnetic fluids

被引:0
|
作者
Li Yao-cheng [1 ]
Wang Hai-tong [2 ]
Zhao Xin [1 ]
机构
[1] Xian Univ Posts & Telecommun, Grad Sch, Xian 710061, Peoples R China
[2] Armed Police Engn Coll, Dept Commun Engn, Xian 710086, Peoples R China
关键词
long period fiber grating; Magnetic fluid; Magnetic field measurement; Temperature characteristics; resonant wavelength;
D O I
10.1117/12.2081733
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper carries out theoretical research and numerical simulation on the temperature characteristics of LPFG magnetic field sensor based on magnetic fluids. The simulation results show that the change of ambient temperature can make coupling resonance wavelength of the long period fiber grating drift, change the refractive index of magnetic fluids, which affects the measurement precision of the magnetic field. Our research has a certain significance for the practical application of LPFG magnetic field sensor based on magnetic fluids.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] LPFG based Fiber Optic Sensor for Magnetic Field Measurement
    Gouveia, Carlos A. J.
    Coelho, Luis
    Franco, Marcos A. R.
    [J]. 2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS), 2017, 10323
  • [2] High sensitive LPFG magnetic field sensor based on dual-peak resonance
    Gu, Zhengtian
    Ling, Qiang
    Lan, Jinlong
    Gao, Kan
    [J]. OPTICS AND LASER TECHNOLOGY, 2017, 96 : 249 - 253
  • [3] System design for adopting magnetofluid and LPFG to measure magnetic field and temperature
    Zhang Jie
    Ge Hai-bo
    Cheng Hao
    Lang Jia-wei
    [J]. SECOND INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING, 2017, 10256
  • [4] Vector Magnetic Field Sensor Based on Excessively Tilted Fiber Grating Assistant with Magnetic Fluids
    Lu, Tean
    Sun, Yuezhen
    Moreno, Yarien
    Yan, Zhijun
    Wang, Changle
    Sun, Qizhen
    Wang, Hushan
    Liu, Deming
    Zhang, Lin
    [J]. 2018 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP), 2018,
  • [5] Analysis of a magnetic field sensor based on photonic crystal fiber selectively infiltrated with magnetic fluids
    Zhang, Wenxun
    Chen, Hailiang
    Liu, Yingchao
    Ma, Mingjian
    Li, Shuguang
    [J]. OPTICAL FIBER TECHNOLOGY, 2018, 46 : 43 - 47
  • [6] Dependence of the Viscosity of Magnetic Fluids on the Concentration of Magnetic Particles, Temperature, and a Magnetic Field
    A. K. Zaripov
    A. Ubaidi
    [J]. Russian Journal of Physical Chemistry A, 2021, 95 : 2141 - 2147
  • [7] Dependence of the Viscosity of Magnetic Fluids on the Concentration of Magnetic Particles, Temperature, and a Magnetic Field
    Zaripov, A. K.
    Ubaidi, A.
    [J]. RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A, 2021, 95 (10) : 2141 - 2147
  • [8] Calorimetric study of magnetic fluids under a magnetic field
    Taketomi, S
    Sorensen, CM
    Klabunde, KJ
    [J]. PHYSICAL REVIEW E, 2003, 68 (02):
  • [9] Characteristics of 2D magnetic field sensor based on magnetic sensitivity diodes
    Zhao, Xiaofeng
    Yang, Xianghong
    Yu, Yang
    Wu, Tong
    Wen, Dianzhong
    [J]. AIP ADVANCES, 2015, 5 (04):
  • [10] Magnetic SAW RFID Sensor Based on Love Wave for Detection of Magnetic Field and Temperature
    Mengue, Prince
    Meistersheim, Laurine
    Hage-Ali, Sami
    Floer, Cecile
    Petit-Watelot, Sebastien
    Lacour, Daniel
    Hehn, Michel
    Elmazria, Omar
    [J]. IEEE JOURNAL OF RADIO FREQUENCY IDENTIFICATION, 2023, 7 : 528 - 535