Computed tomographic analysis of the esophagus, left atrium, and pulmonary veins: implications for catheter ablation of atrial fibrillation

被引:18
|
作者
Jang, Sung-Won [3 ]
Kwon, Beom-June [3 ]
Choi, Min-Seok [3 ]
Kim, Dong-Bin [3 ]
Shin, Woo-Seung [3 ]
Cho, Eun Joo [3 ]
Kim, Ji-Hoon [3 ]
Oh, Yong-Seog [3 ]
Lee, Man-Young [3 ]
Rho, Tai-Ho [3 ]
Kim, Jae-Hyung [3 ]
Lee, Bae-Young [1 ,2 ]
Kim, Hyo-Lim [2 ]
Jung, Jung-Im [2 ]
Song, Kyung-Sup [2 ]
机构
[1] Catholic Univ Korea, St Pauls Hosp, Dept Radiol, Seoul 130709, South Korea
[2] Catholic Univ Korea, Coll Med, Dept Radiol, Seoul 130709, South Korea
[3] Catholic Univ Korea, Coll Med, Dept Internal Med, Div Cardiol, Seoul 130709, South Korea
关键词
Atrial fibrillation; Computed tomography; Pulmonary veins; Esophagus; Atrium; RADIOFREQUENCY ABLATION; FISTULA; TEMPERATURE; PREVALENCE; BALLOON; INJURY;
D O I
10.1007/s10840-011-9594-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to investigate the anatomic relationship around the left atrium (LA) and to provide clinical information to help avoid the risk of an atrio-esophageal fistula during atrial fibrillation (AF) ablation. The multidetector spiral computed tomography images of 77 male patients (mean age, 54 +/- 9 years) with drug-refractory AF and 37 male control subjects (mean age, 50 +/- 11 years) were analyzed. We measured the following variables: (1) distance between the ostia of the pulmonary veins (PVs) and the ipsilateral esophageal border, (2) presence of a pericardial fat pad around each PV, and (3) contact width/length and presence of a fat pad between the LA and the esophagus. The distance between the esophagus and the ostia of right superior PV, right inferior PV (RIPV), left superior PV, and left inferior PV (LIPV) was 27.2 +/- 9.4 mm, 22.9 +/- 10.3 mm, 2.7 +/- 9.4 mm, and 7.1 +/- 8.8 mm, respectively. A fat pad between the esophagus and the superior PV was present in more than 90% of the subjects in both groups. However, the fat pad around inferior PV was present less frequently in the patients than in the control group (p = 0.011, RIPV; p < 0.001, LIPV). The average length of the LA-esophagus contact in the patients and the control group subjects was 26.2 +/- 10.4 and 18.5 +/- 5.1 mm, respectively (p < 0.001). Caution should be exercised when ablating the LIPV because the esophagus is located in close proximity to the left-sided PV and most of the inferior PVs in patients with AF are not covered with fat pads.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [1] Computed tomographic analysis of the esophagus, left atrium, and pulmonary veins: implications for catheter ablation of atrial fibrillation
    Sung-Won Jang
    Beom-June Kwon
    Min-Seok Choi
    Dong-Bin Kim
    Woo-Seung Shin
    Eun Joo Cho
    Ji-Hoon Kim
    Yong-Seog Oh
    Man-Young Lee
    Tai-Ho Rho
    Jae-Hyung Kim
    Bae-Young Lee
    Hyo-Lim Kim
    Jung-Im Jung
    Kyung-Sup Song
    Journal of Interventional Cardiac Electrophysiology, 2011, 32 : 1 - 6
  • [2] Relationship of the esophagus and aorta to the left atrium and pulmonary veins: Implications for catheter ablation of atrial fibrillation
    Cury, RC
    Abbara, S
    Schmidt, S
    Malchano, ZJ
    Neuzil, P
    Weichet, J
    Ferencik, M
    Hoffmann, U
    Ruskin, JN
    Brady, TJ
    Reddy, VY
    HEART RHYTHM, 2005, 2 (12) : 1317 - 1323
  • [3] The relationship of the esophagus and aorta to the left atrium and pulmonary veins: Implications for catheter ablation of atrial fibrillation
    Cury, RC
    Schmidt, S
    Abbara, S
    Malchano, Z
    Neuzil, P
    Weichet, J
    Ruskin, JN
    Brady, TJ
    Reddy, VY
    CIRCULATION, 2004, 110 (17) : 417 - 417
  • [4] Computed tomographic analysis of the anatomy of the left atrium and the esophagus - Implications for left atrial catheter ablation
    Lemola, K
    Sneider, M
    Desjardins, B
    Case, I
    Han, J
    Good, E
    Tamirisa, K
    Tsemo, A
    Chugh, A
    Bogun, F
    Pelosi, F
    Kazerooni, E
    Morady, F
    Oral, H
    CIRCULATION, 2004, 110 (24) : 3655 - 3660
  • [5] Computerized tomographic analysis of the anatomy of the left atrium and the esophagus: Implications for left atrial catheter ablation
    Lemola, K
    Schneider, M
    Desjardins, B
    Case, I
    Han, J
    Good, E
    Tamirisa, K
    Tsemo, A
    Chugh, A
    Bogun, F
    Pelosi, F
    Kazerooni, E
    Morady, F
    Oral, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 114A - 114A
  • [6] Remodeling of the left atrium and pulmonary veins following catheter ablation of atrial fibrillation
    Dalai, D
    Jayam, V
    Vasamreddy, CR
    Lickfett, L
    Bradley, D
    Eldadah, Z
    Dickfeld, T
    Halperin, H
    Berger, R
    Calkins, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 117A - 118A
  • [7] The developing pulmonary veins and left atrium: implications for ablation strategy for atrial fibrillation
    Sherif, Hisham M. F.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 44 (05) : 792 - 799
  • [8] Computed tomography imaging of left atrium and pulmonary veins for radiofrequency ablation of atrial fibrillation
    Stojanovska, Jadranka
    Cronin, Paul
    SEMINARS IN ROENTGENOLOGY, 2008, 43 (02) : 154 - 166
  • [9] Three-dimensional reconstruction of pulmonary veins and left atrium.: Implications for catheter ablation of atrial fibrillation
    Ernst, S
    Broemel, T
    Krumsdorf, U
    Hachiya, H
    Ouyang, F
    Linder, C
    Falk, P
    Bänsch, D
    Schaumann, A
    Kuck, KH
    Antz, M
    HERZ, 2003, 28 (07) : 559 - 565
  • [10] Etectroanatomic reconstruction of the left atrium, pulmonary veins, and esophagus compared with the "true anatomy" on multislice computed tomography in patients undergoing catheter ablation of atrial fibrillation
    Piorkowski, C
    Hindricks, G
    Schreiber, D
    Tanner, H
    Weise, W
    Koch, A
    Gerds-Li, JH
    Kottkamp, H
    HEART RHYTHM, 2006, 3 (03) : 317 - 327