Comparison of force sensors for atomic force microscopy based on quartz tuning forks and length-extensional resonators

被引:84
|
作者
Giessibl, Franz J. [1 ]
Pielmeier, Florian [1 ]
Eguchi, Toyoaki [2 ,3 ]
An, Toshu [4 ]
Hasegawa, Yukio [5 ]
机构
[1] Univ Regensburg, Inst Expt & Appl Phys, D-93040 Regensburg, Germany
[2] Japan Sci & Technol Agcy, NAKAJIMA Designer Nanocluster Assembly Project, ERATO, Takatsu Ku, Kawasaki, Kanagawa 2130012, Japan
[3] Keio Univ, Grad Sch Sci & Technol, Kohoku Ku, Yokohama, Kanagawa 2238522, Japan
[4] Tohoku Univ, Inst Mat Res, Aoba Ku, Sendai, Miyagi 9808577, Japan
[5] Univ Tokyo, Inst Solid State Phys, Chiba 2778581, Japan
关键词
SILICON (111)-(7X7) SURFACE; FREQUENCY-SHIFTS; RESOLUTION; CANTILEVERS; OPERATION;
D O I
10.1103/PhysRevB.84.125409
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The force sensor is key to the performance of atomic force microscopy (AFM). Nowadays, most atomic force microscopes use micromachined force sensors made from silicon, but piezoelectric quartz sensors are being applied at an increasing rate, mainly in vacuum. These self-sensing force sensors allow a relatively easy upgrade of a scanning tunneling microscope to a combined scanning tunneling/atomic force microscope. Two fundamentally different types of quartz sensors have achieved atomic resolution: the "needle sensor," which is based on a length-extensional resonator, and the "qPlus sensor," which is based on a tuning fork. Here, we calculate and measure the noise characteristics of these sensors. We find four noise sources: deflection detector noise, thermal noise, oscillator noise, and thermal drift noise. We calculate the effect of these noise sources as a factor of sensor stiffness, bandwidth, and oscillation amplitude. We find that for self-sensing quartz sensors, the deflection detector noise is independent of sensor stiffness, while the remaining three noise sources increase strongly with sensor stiffness. Deflection detector noise increases with bandwidth to the power of 1.5, while thermal noise and oscillator noise are proportional to the square root of the bandwidth. Thermal drift noise, however, is inversely proportional to bandwidth. The first three noise sources are inversely proportional to amplitude while thermal drift noise is independent of the amplitude. Thus, we show that the earlier finding that quoted an optimal signal-to-noise ratio for oscillation amplitudes similar to the range of the forces is still correct when considering all four frequency noise contributions. Finally, we suggest how the signal-to-noise ratio of the sensors can be improved further, we briefly discuss the challenges of mounting tips, and we compare the noise performance of self-sensing quartz sensors and optically detected Si cantilevers.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Casimir force experiments with quartz tuning forks and an atomic force microscope (AFM)
    Ludwig, T.
    JOURNAL OF PHYSICS A-MATHEMATICAL AND THEORETICAL, 2008, 41 (16)
  • [2] Quartz tuning forks as sensors for attractive-mode force microscopy under ambient conditions
    King, GM
    Lamb, JS
    Nunes, G
    APPLIED PHYSICS LETTERS, 2001, 79 (11) : 1712 - 1714
  • [3] Characterization of strongly coupled quartz tuning fork sensors for precision force measurement in atomic force microscopy
    Shaskey, Cedric
    Jarzembski, Amun
    Jue, Andrew
    Park, Keunhan
    ULTRAMICROSCOPY, 2024, 267
  • [4] Force-gradient-induced mechanical dissipation of quartz tuning fork force sensors used in atomic force microscopy
    Castellanos-Gomez, A.
    Agrait, N.
    Rubio-Bollinger, G.
    ULTRAMICROSCOPY, 2011, 111 (03) : 186 - 190
  • [5] Dynamic force microscopy with quartz tuning forks at high oscillation amplitudes
    Labardi, M.
    NANOTECHNOLOGY, 2007, 18 (08)
  • [6] Noncontact friction force microscopy based on quartz tuning fork sensors
    Labardi, M.
    Allegrini, M.
    APPLIED PHYSICS LETTERS, 2006, 89 (17)
  • [7] Frequency shift, damping, and tunneling current coupling with quartz tuning forks in noncontact atomic force microscopy
    Nony, Laurent
    Bocquet, Franck
    Para, Franck
    Loppacher, Christian
    PHYSICAL REVIEW B, 2016, 94 (11)
  • [8] Atomic Force Microscopy Sidewall Imaging with a Quartz Tuning Fork Force Sensor
    Hussain, Danish
    Wen, Yongbing
    Zhang, Hao
    Song, Jianmin
    Xie, Hui
    SENSORS, 2018, 18 (01):
  • [9] Voltage preamplifier for extensional quartz sensors used in scanning force microscopy
    Morawski, Ireneusz
    Blicharski, Jozef
    Voigtlaender, Bert
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (06):
  • [10] Enhancement of Q factor in quartz tuning fork force sensors for atomic force microscopy through counter piezo excitation
    Kinoshita, Yukinori
    Kamo, Yoshiki
    MECHANICAL ENGINEERING JOURNAL, 2024, 11 (04):