The utility of continuous glucose monitoring systems in the management of children with persistent hypoglycaemia

被引:8
|
作者
Vijayanand, Sathyakala [1 ]
Stevenson, Paul G. [2 ]
Grant, Maree [1 ]
Choong, Catherine S. [1 ,3 ]
Davis, Elizabeth A. [1 ,2 ,3 ]
Abraham, Mary B. [1 ,2 ,3 ]
机构
[1] Perth Childrens Hosp, Dept Endocrinol & Diabet, Perth, WA, Australia
[2] Univ Western Australia, Telethon Kids Inst, Perth, WA, Australia
[3] Univ Western Australia, Perth, WA, Australia
来源
关键词
continuous glucose monitoring; hyperinsulin-ism; hypoglycaemia; CGM;
D O I
10.1515/jpem-2021-0414
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Glucose monitoring is vital in children with persistent hypoglycaemia to reduce the risk of adverse neuro-behavioural outcomes; especially in children with hyperinsulinism. The role of continuous glucose monitoring (CGM) systems in monitoring glucose levels in this cohort is limited. The objective of this study was to ascertain the effectiveness of CGM and to evaluate parents' experience of using CGM for monitoring glucose levels in children with hypoglycaemia. Methods: Retrospective analysis of sensor glucose (SG) values from Dexcom G4 CGM with paired finger-prick blood glucose (BG) values was performed to determine the accuracy of CGM. The parent experience of CGM was assessed using a questionnaire administered to families of children with congenital hyperinsulinism currently attending the clinic. Results: SG data from 40 children (median age 6 months) with persistent hypoglycaemia (60% Hyperinsulinism) were analysed. The mean difference between 5,650 paired BG and SG values was 0.28 mmol/L. The sensitivity and specificity of CGM to identify severe hypoglycaemia (BG < 3.0 mmol/L) were 54.3% (95% CI: 39.0%, 69.1%) and 97.4% (95% CI: 96.9%, 97.8%) respectively. Parents (n=11) reported less anxiety (n=9), better sleep at night (n=7) and preferred to use CGM for monitoring (n=9). Conclusions: Although the high number of false-positive readings precludes the routine use of CGM in the evaluation of hypoglycaemia, it avoids unnecessary BG testing during normoglycaemia. It is an acceptable tool for parents for monitoring their children who are at risk of hypoglycaemia. Newer CGM systems with improved accuracy at lower glucose levels have the potential to further improve monitoring.
引用
收藏
页码:1567 / 1572
页数:6
相关论文
共 50 条
  • [1] The utility of continuous glucose monitoring systems in the management of children with persistent hypoglycaemia
    Vijayanand, Sathyakala
    Stevenson, Paul G.
    Grant, Maree
    Choong, Catherine S.
    Davis, Elizabeth A.
    Abraham, Mary B.
    [J]. HORMONE RESEARCH IN PAEDIATRICS, 2021, 94 (SUPPL 1): : 292 - 293
  • [2] Continuous glucose monitoring for children with hypoglycaemia: Evidence in 2023
    Worth, Chris
    Hoskyns, Lucy
    Salomon-Estebanez, Maria
    Nutter, Paul W.
    Harper, Simon
    Derks, Terry G. J.
    Beardsall, Kathy
    Banerjee, Indraneel
    [J]. FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [3] Continuous glucose monitoring for hypoglycaemia in children: Perspectives in 2020
    Worth, Chris
    Dunne, Mark
    Ghosh, Arunabha
    Harper, Simon
    Banerjee, Indraneel
    [J]. PEDIATRIC DIABETES, 2020, 21 (05) : 697 - 706
  • [4] Nocturnal hypoglycaemia in diabetic children: the role of continuous glucose monitoring (cgms)
    Bachmann, S.
    Ritschard, V.
    Hess, M.
    Jockers, K.
    Zumsteg, U.
    [J]. SWISS MEDICAL WEEKLY, 2014, 144 : 16S - 16S
  • [5] Case for funding of continuous glucose monitoring systems for patients with recurrent hypoglycaemia
    Ng, Sze May
    Dearman, Sarah
    Fisher, Mark
    Mushtaq, Talat
    Randell, Tabitha
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 2023, 108 (10) : 816 - 817
  • [6] Outcomes of a Quality Improvement Project Integrating Continuous Glucose Monitoring Systems Into the Routine Management of Neonatal Hypoglycaemia
    McGlacken-Byrne, Sinead
    Jenkinson, Allan
    O'Neill, Roisin
    Murphy, John
    [J]. HORMONE RESEARCH IN PAEDIATRICS, 2018, 90 : 96 - 96
  • [7] Continuous glucose monitoring: quality of hypoglycaemia detection
    Zijlstra, E.
    Heise, T.
    Nosek, L.
    Heinemann, L.
    Heckermann, S.
    [J]. DIABETES OBESITY & METABOLISM, 2013, 15 (02): : 130 - 135
  • [8] Nocturnal hypoglycaemia in ACTH and GH deficient children: role of continuous glucose monitoring
    Cambiaso, Paola
    Schiaffini, Riccardo
    Pontrelli, Giuseppe
    Carducci, Chiara
    Ubertini, Graziamaria
    Crea, Francesca
    Cappa, Marco
    [J]. CLINICAL ENDOCRINOLOGY, 2013, 79 (02) : 232 - 237
  • [9] Assessment of hypoglycaemia awareness using continuous glucose monitoring
    Kubiak, T
    Hermanns, N
    Schreckling, HJ
    Kulzer, B
    Haak, T
    [J]. DIABETIC MEDICINE, 2004, 21 (05) : 487 - 490
  • [10] Continuous glucose monitoring and hypoglycaemia events: unmet needs
    Papaioannou, Theodore G.
    Sanoudou, Despina
    Tsioufis, Costas
    [J]. DIABETOLOGIA, 2022, 65 (09) : 1569 - 1570